FCC ID R74TM-600U1

Mobile Radio

by Shenzhen HYT Science &Technology; Co Ltd

Grantee Code: R74   Product Code: TM600U1
Latest application date: 2006-11-29

FCC ID Device Details

FCC IDR74TM-600U1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeR74
Product CodeTM600U1
Applicant BusinessShenzhen HYT Science &Technology; Co Ltd 🇨🇳
Related Domains hyt.com.cn
Equipment ClassMobile Radio
Test FirmShenzhen Huatongwei International Insp. Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
400-470 MHzOriginal Equipment2006-11-29

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2006-11-29PDF 1.1 MB
Internal PhotosInternal Photos2006-11-29PDF 591.2 KB
External PhotosExternal Photos2006-11-29PDF 699.9 KB
ID Label InfoID Label/Location Info2006-11-29PDF 233.7 KB
Block DiagramBlock Diagram2006-11-29PDF 538.8 KB
SchematicsSchematics2006-11-29PDF 318.1 KB
Operational DescriptionOperational Description2006-11-29PDF 59.4 KB
Test Setup PhotosTest Setup Photos2006-11-29PDF 145.5 KB
Test ReportTest Report2006-11-29PDF 3.5 MB
Parts ListParts List/Tune Up Info2006-11-29PDF 63.4 KB
RF Exposure InfoRF Exposure Info2006-11-29PDF 55.5 KB
Tune Up InfoParts List/Tune Up Info2006-11-29PDF 325.6 KB

Application Information

Application IDBlie8UwNwZkB6n9JW3qUTA==
Final Action Date2006-11-29
Application PurposeOriginal Equipment
Applicant FRN0008873473
ModelTM-600U1
Frequency Range400-470 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionMobile Radio
Responsible PartyXiong Lei, rd@hyt.com.cn , 0755-26972999
Test FirmMoffy Yu, Shenzhen Huatongwei International Insp. Co., Ltd, moffy.yu@szhtw.com.cn , 86-755-26748078
TCB Emailkknoerig@emcc.de
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is peak conducted. The antennas used for this transmitter must be vehicle-mounted as described in this filing. The maximum antenna gain must not exceed 3 dBi. This radio must operate in push-to-talk mode with a duty factor not exceeding 50% and must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled exposure limit and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit.

Applications

Application IDDatePurpose
Blie8UwNwZkB6n9JW3qUTA==2006-11-29Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
400-470 MHz252ppm11K0F3E9
400-470 MHz252.8ppm16K0F3E9

Grants

TCB Grant - Application Blie8UwNwZkB6n9JW3qUTA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  EMCCons DR RASEK GmbH & Co. KG
Stoernhofer Berg 15
Unterleinleiter, 91364
Germany
Date of Grant: 11/29/2006

Application Dated: 11/29/2006
Shenzhen HYT Science &Technology Co Ltd
R2-High-Tech Industrial Park
Shenzhen,
China
 
Attention: Xiong Lei

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  R74TM-600U1
Name of Grantee:  Shenzhen HYT Science &Technology Co Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Mobile Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 400.0  -  470.0 25.0 2.0  PM 11K0F3E
90 400.0  -  470.0 25.0 2.8  PM 16K0F3E

Output power is peak conducted. The antennas used for this transmitter must be vehicle-mounted as described in this filing. The maximum antenna gain must not exceed 3 dBi. This radio must operate in push-to-talk mode with a duty factor not exceeding 50% and must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled exposure limit and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit.

EAS Grant - Application Blie8UwNwZkB6n9JW3qUTA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen HYT Science &Technology Co Ltd
R2-High-Tech Industrial Park
Shenzhen,
China
  Date of Grant: 11/29/2006

Application Dated: 11/29/2006
 
Attention: Xiong Lei

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  R74TM-600U1
Name of Grantee:  Shenzhen HYT Science &Technology Co Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Mobile Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 400.0  -  470.0 25.0 2.0  PM 11K0F3E
90 400.0  -  470.0 25.0 2.8  PM 16K0F3E

Output power is peak conducted. The antennas used for this transmitter must be vehicle-mounted as described in this filing. The maximum antenna gain must not exceed 3 dBi. This radio must operate in push-to-talk mode with a duty factor not exceeding 50% and must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled exposure limit and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit.