Test FirmSGS-CSTC Standards Technical Services (Suzhou) Co.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5775 MHzOriginal Equipment2026-08-27
2402-2480 MHzOriginal Equipment2026-08-27
6105-6905 MHzOriginal Equipment2026-08-27
2422-2452 MHzOriginal Equipment2026-08-27
13.56 MHzOriginal Equipment2026-08-27

Exhibits

DocumentTypeAvailableFile
LabelID Label/Location Info2026-08-27PDF 103.1 KB
Antenna Data SheetTest Report2026-08-27PDF 2.6 MB
FCC 2.4G WIFI Test Report_part1Test Report2026-08-27PDF 4.1 MB
FCC 2.4G WIFI Test Report_part2Test Report2026-08-27PDF 5.6 MB
FCC 5G WIFI Test Report_part1Test Report2026-08-27PDF 5.5 MB
FCC 5G WIFI Test Report_part2Test Report2026-08-27PDF 5.3 MB
FCC 5G WIFI Test Report_part3Test Report2026-08-27PDF 5.7 MB
FCC 5G WIFI Test Report_part4Test Report2026-08-27PDF 5.9 MB
FCC 5G WIFI Test Report_part5Test Report2026-08-27PDF 5 MB
FCC 5G WIFI Test Report_part6Test Report2026-08-27PDF 5.3 MB
FCC 6E WIFI Test Report_part1Test Report2026-08-27PDF 5.7 MB
FCC 6E WIFI Test Report_part2Test Report2026-08-27PDF 5.4 MB
FCC 6E WIFI Test Report_part3Test Report2026-08-27PDF 5.5 MB
FCC 6E WIFI Test Report_part4Test Report2026-08-27PDF 4.9 MB
FCC 6E WIFI Test Report_part5Test Report2026-08-27PDF 5.1 MB
FCC 6E WIFI Test Report_part6Test Report2026-08-27PDF 5.8 MB
FCC BLE Test Report_part1Test Report2026-08-27PDF 3.7 MB
FCC BLE Test Report_part2Test Report2026-08-27PDF 4.8 MB
FCC BT Test ReportTest Report2026-08-27PDF 3.2 MB
FCC NFC Test ReportTest Report2026-08-27PDF 1.8 MB
Justification statement for AntennaTest Report2026-08-27PDF 130.8 KB
FCC Attastation Letter for 6XDAttestation Statements2026-08-27PDF 150.5 KB
FCC CoverList-AttestationAttestation Statements2026-08-27PDF 258.2 KB
FCC U.S. agent LetterAttestation Statements2026-08-27PDF 674 KB
QSF27-14-04_Rev1.4_Applicant_Declaration_LetterAttestation Statements2026-08-27PDF 313.6 KB
Auth LetterCover Letter(s)2026-08-27PDF 174.6 KB
Confidentiality letterCover Letter(s)2026-08-27PDF 202.4 KB
E Label declaration letterCover Letter(s)2026-08-27PDF 177.2 KB
Appendix A Detailed System Check ResultsRF Exposure Info2026-08-27PDF 899.8 KB
Appendix B Detailed Test ResultsRF Exposure Info2026-08-27PDF 1,016.7 KB
Appendix C Calibration certificate_part1RF Exposure Info2026-08-27PDF 3.9 MB
Appendix C Calibration certificate_part2RF Exposure Info2026-08-27PDF 5.6 MB
Appendix E Conducted RF Output PowerRF Exposure Info2026-08-27PDF 2.4 MB
FCC SAR ReportRF Exposure Info2026-08-27PDF 3.6 MB
User Manual_Part1 Metadata onlyUsers Manual2027-02-24PDF 1.8 MB
User Manual_Part2 Metadata onlyUsers Manual2027-02-24PDF 3 MB
Internal photo Metadata onlyInternal Photos2027-02-24PDF 2.7 MB
External photo Metadata onlyExternal Photos2027-02-24PDF 1.6 MB
Appendix D Photographs Metadata onlyTest Setup Photos2027-02-24PDF 2 MB
Test setup photo Metadata onlyTest Setup Photos2027-02-24PDF 1.2 MB
Block diagram Metadata onlyBlock DiagramPDF 139.4 KB
Schematics Metadata onlySchematicsPDF 1.5 MB
Operational description Metadata onlyOperational DescriptionPDF 231.7 KB
NII Software Security Info Metadata onlySDR Software/Security Info.PDF 228.4 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 465.2 KB
Tune up Metadata onlyParts List/Tune Up InfoPDF 69 KB

Application Information

Application IDqyO0HDAbTC55AD4qBF2KDQ==
Final Action Date2026-08-27
Application PurposeOriginal Equipment
Applicant FRN0009419870
Model1995B
Frequency Range5775 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionHandheld Terminal
Responsible PartyKatsuya Ota, regulatorykj@keyence.co.jp , +81-6-6379-1111
Technical ContactParlam Zhan, SGS-CSTC Standards Technical Services Co., Ltd., Parlam.zhan@sgs.com , 02161915666
Non-Technical ContactBrian Gaehring, Keyence Corporation of America, Brian.Gaehring@keyence.com , (888) 539-3623 70701
Test FirmMia Zhou, SGS-CSTC Standards Technical Services (Suzhou) Co., Mia.Zhou@sgs.com , 86-18550061259
TCB EmailUSCTS.TCB@SGS.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes

Applications

Application IDDatePurpose
qyO0HDAbTC55AD4qBF2KDQ==2026-08-27Original Equipment
YKZMPC9wZ1qli4phaMfFVw==2026-08-27Original Equipment
Y1NXQquG1DclfSNYrkFu1w==2026-08-27Original Equipment
TAabIkO2zT7rjPRENiSMtg==2026-08-27Original Equipment
C1w2IGOTz5AjKrBvb6yXNA==2026-08-27Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.004515CCC
5955-7115 MHz0.007715ECC EP MO
5965-7085 MHz0.013815ECC EP MO
5985-7025 MHz0.029415ECC EP MO
6025-6985 MHz0.052815ECC EP MO
6105-6905 MHz0.0815ECC EP MO
2402-2480 MHz0.012415CCC
2412-2462 MHz0.959415CCC MO
2422-2452 MHz0.986315CCC MO
5180-5240 MHz0.138415ECC MO
5190-5230 MHz0.122515ECC MO
5210 MHz0.079615ECC MO
5250 MHz0.058515ECC MO
5260-5320 MHz0.126815ECC MO
5270-5310 MHz0.110415ECC MO
5290 MHz0.070315ECC MO
5500-5720 MHz0.092315ECC MO
5510-5710 MHz0.091615ECC MO
5530-5690 MHz0.092515ECC MO
5570 MHz0.08315ECC MO
5745-5825 MHz0.128515ECC MO
5755-5795 MHz0.113215ECC MO
5775 MHz0.110415ECC MO
13.56 MHz15CCC

Grants

TCB Grant - Application YKZMPC9wZ1qli4phaMfFVw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 08/27/2026

Application Dated: 07/08/2026
Keyence Corporation
1-3-14, Higashinakajima
Higashiyodogawa-ku
Osaka, 533-8555
Japan
 
Attention: Katsuya Ota , Manager, Product Safety & Compliance Department

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RF41995B
Name of Grantee:  Keyence Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Handheld Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0045  

Power Output listed is conducted. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory, hotspot and simultaneous transmission use conditions are 0.1 W/kg, 0.1 W/kg and 1.59W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application Y1NXQquG1DclfSNYrkFu1w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 08/27/2026

Application Dated: 07/08/2026
Keyence Corporation
1-3-14, Higashinakajima
Higashiyodogawa-ku
Osaka, 533-8555
Japan
 
Attention: Katsuya Ota , Manager, Product Safety & Compliance Department

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RF41995B
Name of Grantee:  Keyence Corporation
Equipment Class: 15E 6 GHz Low Power Indoor Client
Notes: Handheld Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC EP MO 15E 5955.0  -  7115.0 0.0077  
CC EP MO 15E 5965.0  -  7085.0 0.0138  
CC EP MO 15E 5985.0  -  7025.0 0.0294  
CC EP MO 15E 6025.0  -  6985.0 0.0528  
CC EP MO 15E 6105.0  -  6905.0 0.08  

Power Output listed is EIRP. The device is restricted to indoor use only when operating in the 5925 to 7125 MHz frequency range. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are 0.58 W/kg and 1.59W/kg respectively.

This device supports 20,40,80, 160 and 320MHz bandwidths modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application TAabIkO2zT7rjPRENiSMtg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 08/27/2026

Application Dated: 07/08/2026
Keyence Corporation
1-3-14, Higashinakajima
Higashiyodogawa-ku
Osaka, 533-8555
Japan
 
Attention: Katsuya Ota , Manager, Product Safety & Compliance Department

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RF41995B
Name of Grantee:  Keyence Corporation
Equipment Class: Digital Transmission System
Notes: Handheld Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0124  
CC MO 15C 2412.0  -  2462.0 0.9594  
CC MO 15C 2422.0  -  2452.0 0.9863  

Power Output listed is conducted. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory, hotspot and simultaneous transmission use conditions are 0.57 W/kg, 0.14 W/kg and 1.59W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application qyO0HDAbTC55AD4qBF2KDQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 08/27/2026

Application Dated: 07/08/2026
Keyence Corporation
1-3-14, Higashinakajima
Higashiyodogawa-ku
Osaka, 533-8555
Japan
 
Attention: Katsuya Ota , Manager, Product Safety & Compliance Department

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RF41995B
Name of Grantee:  Keyence Corporation
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Handheld Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.1384  
CC MO 15E 5190.0  -  5230.0 0.1225  
CC MO 15E 5210.0  -  5210.0 0.0796  
CC MO 15E 5250.0  -  5250.0 0.0585  
CC MO 15E 5260.0  -  5320.0 0.1268  
CC MO 15E 5270.0  -  5310.0 0.1104  
CC MO 15E 5290.0  -  5290.0 0.0703  
CC MO 15E 5500.0  -  5720.0 0.0923  
CC MO 15E 5510.0  -  5710.0 0.0916  
CC MO 15E 5530.0  -  5690.0 0.0925  
CC MO 15E 5570.0  -  5570.0 0.083  
CC MO 15E 5745.0  -  5825.0 0.1285  
CC MO 15E 5755.0  -  5795.0 0.1132  
CC MO 15E 5775.0  -  5775.0 0.1104  

Power Output listed is conducted. SAR compliance for body-worn operating configurations is limited to the belt- clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are 1.03 W/kg and 1.59W/kg respectively.

This device supports 20,40,80 and 160MHz bandwidths modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application C1w2IGOTz5AjKrBvb6yXNA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 08/27/2026

Application Dated: 07/08/2026
Keyence Corporation
1-3-14, Higashinakajima
Higashiyodogawa-ku
Osaka, 533-8555
Japan
 
Attention: Katsuya Ota , Manager, Product Safety & Compliance Department

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RF41995B
Name of Grantee:  Keyence Corporation
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Handheld Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  

The highest reported SAR values for product specific (10g SAR) use conditions is <0.10 W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.