FCC ID RFLUX380

FIXED WLL TELEPHONE (CDMA)

by UBISTAR CO.,LTD.

Grantee Code: RFL   Product Code: UX380
Latest application date: 2006-01-12

FCC ID Device Details

FCC IDRFLUX380
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeRFL
Product CodeUX380
Applicant BusinessUBISTAR CO.,LTD. 🇰🇷
Related Domains ubistar.com
Equipment ClassFIXED WLL TELEPHONE (CDMA)
Test FirmLTA Co.,Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.7-848.31 MHzOriginal Equipment2006-01-12

Exhibits

DocumentTypeAvailableFile
USERS MANUALUsers Manual2006-01-12PDF 1.6 MB
INTERNAL PHOTOSInternal Photos2006-01-12PDF 511.2 KB
EXTERNAL PHOTOSExternal Photos2006-01-12PDF 479.1 KB
LABEL LOCATIONID Label/Location Info2006-01-12PDF 106.2 KB
SAR TEST SETUP PHOTORF Exposure Info2006-01-12PDF 86.2 KB
TEST SETUP PHOTOSTest Setup Photos2006-01-12PDF 246.3 KB
RC OUTPUT POWER TABLETest Report2006-01-12PDF 99.6 KB
SAR TEST REPORTRF Exposure Info2006-01-12PDF 652.1 KB
TEST REPORTTest Report2006-01-12PDF 862.2 KB
CONFIDENTIALITY LETTERCover Letter(s)2006-01-12PDF 17.9 KB
SAR PROBE CALIBRATIONRF Exposure Info2006-01-12PDF 1.5 MB
SAR TEST PLOTSRF Exposure Info2006-01-12PDF 455.7 KB
VALIDATION INFORF Exposure Info2006-01-12PDF 234.4 KB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 211.4 KB
SCHEMATICS Metadata onlySchematicsPDF 524.6 KB
OPERATIONAL DESCRIPTION Metadata onlyOperational DescriptionPDF 1.8 MB
PARTS LIST Metadata onlyParts List/Tune Up InfoPDF 70.5 KB
TUNE UP PROCEDURE Metadata onlyParts List/Tune Up InfoPDF 59.3 KB

Application Information

Application IDy/UTvprFaRiHT/hnALBPTg==
Final Action Date2006-01-12
Application PurposeOriginal Equipment
Applicant FRN0011106358
ModelUX380
Frequency Range824.7-848.31 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionFIXED WLL TELEPHONE (CDMA)
Responsible PartyJin-Sik Min, Director, jsmin@ubistar.com , 82-2-549-8402
Test FirmAhn Chulho, LTA Co.,Ltd, chahn@ltalab.com , 82-31-323-6008
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP. SAR compliance for body-worn operating configuration is based on a separation distance of 2.5cm between the base of the antenna and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. This device must not be co-located or operating in conjunction with any other antenna or transmitter. The highest reported SAR value is: W/kg; Body: 0.841 W/kg.

Applications

Application IDDatePurpose
y/UTvprFaRiHT/hnALBPTg==2006-01-12Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.7-848.31 MHz0.47600002.5000000000ppm1M25F9W22H

Grants

TCB Grant - Application y/UTvprFaRiHT/hnALBPTg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 01/12/2006

Application Dated: 01/12/2006
UBISTAR CO.,LTD.
7F, Seongdo Building, 587-23, Sinsa-Dong
Gangnam-Gu
Seoul, 135-747
South Korea
 
Attention: Jin-Sik Min , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RFLUX380
Name of Grantee:  UBISTAR CO.,LTD.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: FIXED WLL TELEPHONE (CDMA)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.476 2.5  PM 1M25F9W

Output power listed is ERP. SAR compliance for body-worn operating configuration is based on a separation distance of 2.5cm between the base of the antenna and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. This device must not be co-located or operating in conjunction with any other antenna or transmitter. The highest reported SAR value is: W/kg; Body: 0.841 W/kg.

EAS Grant - Application y/UTvprFaRiHT/hnALBPTg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

UBISTAR CO.,LTD.
7F, Seongdo Building, 587-23, Sinsa-Dong Gangnam-Gu
Seoul, 135-747
South Korea
  Date of Grant: 01/12/2006

Application Dated: 01/12/2006
 
Attention: Jin-Sik Min , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RFLUX380
Name of Grantee:  UBISTAR CO.,LTD.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: FIXED WLL TELEPHONE (CDMA)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.476 2.5  PM 1M25F9W

Output power listed is ERP. SAR compliance for body-worn operating configuration is based on a separation distance of 2.5cm between the base of the antenna and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. This device must not be co-located or operating in conjunction with any other antenna or transmitter. The highest reported SAR value is: W/kg; Body: 0.841 W/kg.