FCC ID RG9BT4100

Pulse oximeter containing Bluetooth

by Nonin Medical, Inc.

Grantee Code: RG9   Product Code: BT4100
Latest application date: 2003-09-25

FCC ID Device Details

FCC IDRG9BT4100
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeRG9
Product CodeBT4100
Applicant BusinessNonin Medical, Inc. 🇺🇸
Related Domains nonin.com
Equipment ClassPulse oximeter containing Bluetooth
Test FirmEurofins Product Service GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2003-09-25

Exhibits

DocumentTypeAvailableFile
UserManUsers Manual2003-09-25PDF 251.1 KB
PhotosInternal Photos2003-09-25PDF 417.8 KB
PhotosExternal Photos2003-09-25PDF 153.8 KB
LabelID Label/Location Info2003-09-25PDF 230.7 KB
Label LocationID Label/Location Info2003-09-25PDF 43.2 KB
PhotosTest Setup Photos2003-09-25PDF 304.8 KB
Test Report1Test Report2003-09-25PDF 384.6 KB
Test Report2Test Report2003-09-25PDF 1.6 MB
Cover LetterCover Letter(s)2003-09-25PDF 443.5 KB
SARRF Exposure Info2003-09-25PDF 2.7 MB
Block Diagram Metadata onlyBlock DiagramPDF 53.5 KB
Schematic Metadata onlySchematicsPDF 48.2 KB
AntSpec Metadata onlyOperational DescriptionPDF 20.9 KB
OpDes Metadata onlyOperational DescriptionPDF 99.2 KB
Part List Metadata onlyParts List/Tune Up InfoPDF 759.9 KB

Application Information

Application IDoFReOnYU3wQ0wjVWPJvohw==
Final Action Date2003-09-25
Application PurposeOriginal Equipment
Applicant FRN0009448747
ModelBT4100
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionPulse oximeter containing Bluetooth
Responsible PartyBrodie Pedersen, Senior Regulatory Engineer, Brodie.Pedersen@nonin.com , 763-577-3180
Technical ContactSamuel K Foos, Nonin Medical, Inc., samfoos@nonin.com , 763-577-3134
Test FirmRobert Kschiwan-Kaspar, Eurofins Product Service GmbH, rkk@eurofins.de , 49-33631-888-000
TCB Emailbzt@ets-bzt.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThe Pulse oximeter unit conducted output power is 1.1mW and radiated output power is 1.5mW . The highest reported SAR value is: 0.0175W/kg.

Applications

Application IDDatePurpose
oFReOnYU3wQ0wjVWPJvohw==2003-09-25Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.001100015C

Grants

TCB Grant - Application oFReOnYU3wQ0wjVWPJvohw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 09/25/2003

Application Dated: 09/25/2003
Nonin Medical, Inc.
13700 1st Avenue North
Plymouth, MN 55441-5443
 
Attention: Brodie Pedersen , Senior Regulatory Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RG9BT4100
Name of Grantee:  Nonin Medical, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Pulse oximeter containing Bluetooth
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0011  

The Pulse oximeter unit conducted output power is 1.1mW and radiated output power is 1.5mW . The highest reported SAR value is: 0.0175W/kg.

EAS Grant - Application oFReOnYU3wQ0wjVWPJvohw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Nonin Medical, Inc.
13700 1st Avenue North
Plymouth, MN 55441-5443
United States
  Date of Grant: 09/25/2003

Application Dated: 09/25/2003
 
Attention: Brodie Pedersen , Senior Regulatory Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RG9BT4100
Name of Grantee:  Nonin Medical, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Pulse oximeter containing Bluetooth
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0011  

The Pulse oximeter unit conducted output power is 1.1mW and radiated output power is 1.5mW . The highest reported SAR value is: 0.0175W/kg.



Mail To: