FCC ID RIAHCPLUS3180-T
Housecall Plus Transmitter
by St. Jude Medical
Grantee Code: RIA Product Code: HCPLUS3180T
Latest application date: 2003-10-03
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 0.064 MHz | Original Equipment | 2003-10-03 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| users manual | Users Manual | 2003-10-03 | PDF 979.4 KB |
| internal photos | Internal Photos | 2003-10-03 | PDF 187.4 KB |
| external photos | External Photos | 2003-10-03 | PDF 509.1 KB |
| label | ID Label/Location Info | 2003-10-03 | PDF 210.7 KB |
| label location | ID Label/Location Info | 2003-10-03 | PDF 136.2 KB |
| block diagram | Block Diagram | 2003-10-03 | PDF 334.7 KB |
| description | Operational Description | 2003-10-03 | PDF 334.7 KB |
| test setup photos I | Test Setup Photos | 2003-10-03 | PDF 1.3 MB |
| test setup photos II | Test Setup Photos | 2003-10-03 | PDF 2.6 MB |
| Further RT | Test Report | 2003-10-03 | PDF 38.9 KB |
| RT Sep 26 | Test Report | 2003-10-03 | PDF 15.3 KB |
| Response to RT | Test Report | 2003-10-03 | PDF 32 KB |
| test report | Test Report | 2003-10-03 | PDF 1.1 MB |
| agent authorization | Cover Letter(s) | 2003-10-03 | PDF 146.1 KB |
| confidentiality request | Cover Letter(s) | 2003-10-03 | PDF 148 KB |
| schematics Metadata only | Schematics | PDF 708.3 KB |
Application Information
| Application ID | MSt/5zwmVvgaMbVMSpAaKg== |
|---|---|
| Final Action Date | 2003-10-03 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0028172476 |
| Model | HCPLUS3180-T |
| Frequency Range | 0.064 MHz |
| Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz |
| Device Description | Housecall Plus Transmitter |
| Responsible Party | Jennifer A Wong, Director, Regulatory Affairs, jwong03@sjm.com |
| Agent | Chris Chris Chris, MET Laboratories, Inc., tcbinfo@metlabs.com |
| Test Firm | Mark Render, KTL, ktl@ktl.com |
| TCB Email | tcbinfo@metlabs.com |
| TCB Scope | A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | This Transmitter Communicates with the Implanted Device via a telemetry ‘wand’ over a short range (6 inches) inductive link, operating at 64kHz transmit, 8kHz receive. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| MSt/5zwmVvgaMbVMSpAaKg== | 2003-10-03 | Original Equipment |
Grants
TCB Grant - Application MSt/5zwmVvgaMbVMSpAaKg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Electrical and Electronic Testing NA, Inc 914 W. Patapsco Avenue Baltimore, MD 21230-3432 |
Date of Grant: 10/03/2003 Application Dated: 10/03/2003 |
| St. Jude Medical |
| 15900 Valley View Court |
| Sylmar, CA 91342 |
| Attention: Jennifer Wong , Director, Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RIAHCPLUS3180-T |
| Name of Grantee: | St. Jude Medical |
| Equipment Class: | Part 15 Low Power Transmitter Below 1705 kHz |
| Notes: | Housecall Plus Transmitter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CE | 15C | 0.064 - 0.064 |
| This Transmitter Communicates with the Implanted Device via a telemetry wand over a short range (6 inches) inductive link, operating at 64kHz transmit, 8kHz receive. |
| CE: | This device has shown compliance with the conducted emissions limits in 15.107, 15.207, or 18.307 adopted under FCC 02-157 (ET Docket 98-80). The device may be marketed after July 11, 2005, and is not affected by the 15.37(j) or 18.123 transition provisions. |
EAS Grant - Application MSt/5zwmVvgaMbVMSpAaKg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
St. Jude Medical 15900 Valley View Court Sylmar, CA 91342 United States |
Date of Grant: 10/03/2003 Application Dated: 10/03/2003 |
| Attention: Jennifer Wong , Director, Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RIAHCPLUS3180-T |
| Name of Grantee: | St. Jude Medical |
| Equipment Class: | Part 15 Low Power Transmitter Below 1705 kHz |
| Notes: | Housecall Plus Transmitter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CE | 15C | 0.064 - 0.064 |
| This Transmitter Communicates with the Implanted Device via a telemetry wand over a short range (6 inches) inductive link, operating at 64kHz transmit, 8kHz receive. |
| CE: | This device has shown compliance with the conducted emissions limits in 15.107, 15.207, or 18.307 adopted under FCC 02-157 (ET Docket 98-80). The device may be marketed after July 11, 2005, and is not affected by the 15.37(j) or 18.123 transition provisions. |
| Mail To: |