FCC ID RJAI-2000

E-GSM1900 GPRS Terminal Equipment

by Innostream Inc.

Grantee Code: RJA   Product Code: I2000
Latest application date: 2003-10-20

FCC ID Device Details

FCC IDRJAI-2000
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeRJA
Product CodeI2000
Applicant BusinessInnostream Inc. 🇰🇷
Related Domains innostream.com
Equipment ClassE-GSM1900 GPRS Terminal Equipment
Test FirmEurofins Product Service GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2003-10-20

Exhibits

DocumentTypeAvailableFile
UserManUsers Manual2003-10-20PDF 368.1 KB
PhotosInternal Photos2003-10-20PDF 609.8 KB
PhotosExternal Photos2003-10-20PDF 434 KB
LocationID Label/Location Info2003-10-20PDF 34 KB
SampleID Label/Location Info2003-10-20PDF 9.2 KB
OpDescOperational Description2003-10-20PDF 220.3 KB
PhotosTest Setup Photos2003-10-20PDF 469.3 KB
TestRep1Test Report2003-10-20PDF 313.1 KB
TestRep2Test Report2003-10-20PDF 1.4 MB
Cover LetterCover Letter(s)2003-10-20PDF 361.1 KB
SAR1RF Exposure Info2003-10-20PDF 1.8 MB
SAR2RF Exposure Info2003-10-20PDF 2.6 MB
SAR3RF Exposure Info2003-10-20PDF 968 KB
BlkDiagram Metadata onlyBlock DiagramPDF 27.5 KB
Antenna Metadata onlySchematicsPDF 698.4 KB
Schematics Metadata onlySchematicsPDF 127.9 KB
PartList Metadata onlyParts List/Tune Up InfoPDF 55.6 KB
Tune up Info Metadata onlyParts List/Tune Up InfoPDF 12.1 KB

Application Information

Application ID9W8yMFf+4JObmtTy1KdK9w==
Final Action Date2003-10-20
Application PurposeOriginal Equipment
Applicant FRN0009349481
ModelI-2000
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionE-GSM1900 GPRS Terminal Equipment
Responsible PartySi–Chul Kim, hiseungteak@innostream.com , 82317073860
Technical ContactErin Cha, Innostream Inc., erin@innostream.com , 82317073860
Test FirmRobert Kschiwan-Kaspar, Eurofins Product Service GmbH, rkk@eurofins.de , 49-33631-888-000
TCB Emailtcb@ets-bzt.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is EIRP. SAR compliance for body-worn operations is restricted to belt-clips, holsters and accessories supplied or designated for this product. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Body-worn: 0.351 W/kg, Head: 1.39 W/kg. This device contains 900/1800MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.

Applications

Application IDDatePurpose
9W8yMFf+4JObmtTy1KdK9w==2003-10-20Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
1850.2-1909.8 MHz0.84100001.0000000000ppm248KGXW24ECE

Grants

TCB Grant - Application 9W8yMFf+4JObmtTy1KdK9w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 10/20/2003

Application Dated: 10/20/2003
Innostream Inc.
9F Allianz Bldg.267-3, Seohyeon-Dong,
Bundang-gu
Sungnam-shi, Kyunggi-do, 463-824
South Korea
 
Attention: Si�Chul Kim

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RJAI-2000
Name of Grantee:  Innostream Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: E-GSM1900 GPRS Terminal Equipment
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CE 24E 1850.2  -  1909.8 0.841 1.0  PM 248KGXW

Power listed is EIRP. SAR compliance for body-worn operations is restricted to belt-clips, holsters and accessories supplied or designated for this product. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Body-worn: 0.351 W/kg, Head: 1.39 W/kg. This device contains 900/1800MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.

CE: This device has shown compliance with the conducted emissions limits in 15.107, 15.207, or 18.307 adopted under FCC 02-157 (ET Docket 98-80). The device may be marketed after July 11, 2005, and is not affected by the 15.37(j) or 18.123 transition provisions.

EAS Grant - Application 9W8yMFf+4JObmtTy1KdK9w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Innostream Inc.
9F Allianz Bldg.267-3, Seohyeon-Dong, Bundang-gu
Sungnam-shi, Kyunggi-do, 463-824
South Korea
  Date of Grant: 10/20/2003

Application Dated: 10/20/2003
 
Attention: Si–Chul Kim

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RJAI-2000
Name of Grantee:  Innostream Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: E-GSM1900 GPRS Terminal Equipment
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CE 24E 1850.2  -  1909.8 0.841 1.0  PM 248KGXW

Power listed is EIRP. SAR compliance for body-worn operations is restricted to belt-clips, holsters and accessories supplied or designated for this product. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Body-worn: 0.351 W/kg, Head: 1.39 W/kg. This device contains 900/1800MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.


CE: This device has shown compliance with the conducted emissions limits in 15.107, 15.207, or 18.307 adopted under FCC 02-157 (ET Docket 98-80). The device may be marketed after July 11, 2005, and is not affected by the 15.37(j) or 18.123 transition provisions.