Low Power Direct Sequence Spread Spectrum Tx.

by Selex Communications Limited

Grantee Code: RMJ   Product Code: PRR0001
Latest application date: 2004-06-11

FCC ID Device Details

FCC IDRMJPRR0001
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeRMJ
Product CodePRR0001
Applicant BusinessSelex Communications Limited 🇬🇧
Related Domains marconiselenia.com
Equipment ClassLow Power Direct Sequence Spread Spectrum Tx.
Test FirmRFI Global Services Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2406.5-2474 MHzOriginal Equipment2004-06-11

Exhibits

DocumentTypeAvailableFile
Operating InstructionsUsers Manual2004-06-11PDF 80.5 KB
External PhotographsExternal Photos2004-06-11PDF 1,008.6 KB
LabelsID Label/Location Info2004-06-11PDF 2.8 MB
Test Set Up PhotosTest Setup Photos2004-06-11PDF 102 KB
Test reportTest Report2004-06-11PDF 600.6 KB
ConfidentialityCover Letter(s)2004-06-11PDF 201.5 KB
RF Exposure ReportRF Exposure Info2004-06-11PDF 3.3 MB
Internal Photographs Metadata onlyInternal PhotosPDF 2.4 MB
Block Diagram Metadata onlyBlock DiagramPDF 61 KB
Digital ccts Metadata onlySchematicsPDF 364.3 KB
Interconnect ccts Metadata onlySchematicsPDF 124 KB
RF Pcbs Metadata onlySchematicsPDF 560.5 KB
Transceiver layout Metadata onlySchematicsPDF 195.7 KB
Operational Description Metadata onlyOperational DescriptionPDF 80.9 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 289.8 KB

Application Information

Application ID4+9FMrK1+cl81sbJovBeXw==
Final Action Date2004-06-11
Application PurposeOriginal Equipment
Applicant FRN0009831462
ModelPRR0001
Frequency Range2406.5-2474 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionLow Power Direct Sequence Spread Spectrum Tx.
Responsible PartyDavid L Gauld, Technical Manager, david.gauld@marconiselenia.com , 441245275616
Technical ContactMichael Lock, MarconiSelenia Communications Ltd, +44 12455366
Test FirmAllan Hume, RFI Global Services Ltd., alan.hume@rfi-global.com , 44-1256-855439
TCB Emailnick.cobb@rfi-wireless.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is EIRP and must not exceed that tested for SAR compliance. Body-worn SAR compliance is limited to the specific speaker/microphone configurations tested for this filing. The highest reported SAR values is - Body-worn: 0.177 W/kg accounting for a 100% duty cycle

Applications

Application IDDatePurpose
4+9FMrK1+cl81sbJovBeXw==2004-06-11Original Equipment

Equipment Authorization

FrequencyOutputRules
2406.5-2474 MHz0.083000015C

Grants

TCB Grant - Application 4+9FMrK1+cl81sbJovBeXw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL International (UK) Ltd
Unit 1 - 3 Horizon Kingsland Business Park Wade Road
Basingstoke, RG24 8AH
United Kingdom
Date of Grant: 06/11/2004

Application Dated: 06/11/2004
Selex Communications Limited
New Street
Chelmsford, CM1 1PL
United Kingdom
 
Attention: David Gauld , Technical Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RMJPRR0001
Name of Grantee:  Selex Communications Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Low Power Direct Sequence Spread Spectrum Tx.
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2406.5  -  2474.0 0.083  

Power Output listed is EIRP and must not exceed that tested for SAR compliance. Body-worn SAR compliance is limited to the specific speaker/microphone configurations tested for this filing. The highest reported SAR values is - Body-worn: 0.177 W/kg accounting for a 100% duty cycle

EAS Grant - Application 4+9FMrK1+cl81sbJovBeXw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Selex Communications Limited
New Street
Chelmsford, CM1 1PL
United Kingdom
  Date of Grant: 06/11/2004

Application Dated: 06/11/2004
 
Attention: David Gauld , Technical Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RMJPRR0001
Name of Grantee:  Selex Communications Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Low Power Direct Sequence Spread Spectrum Tx.
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2406.5  -  2474.0 0.083  

Power Output listed is EIRP and must not exceed that tested for SAR compliance. Body-worn SAR compliance is limited to the specific speaker/microphone configurations tested for this filing. The highest reported SAR values is - Body-worn: 0.177 W/kg accounting for a 100% duty cycle



Mail To: