FCC ID RNGM900RFX

ReFlex Telemetry Device

by Hunetec Co., Ltd

Grantee Code: RNG   Product Code: M900RFX
Latest application date: 2006-01-30

FCC ID Device Details

FCC IDRNGM900RFX
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeRNG
Product CodeM900RFX
Applicant BusinessHunetec Co., Ltd 🇰🇷
Related Domains hunetec.com
Equipment ClassReFlex Telemetry Device
Test FirmONETECH Corp.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
896-901 MHzOriginal Equipment2006-01-30

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2006-01-30PDF 913.5 KB
Internal PhotosInternal Photos2006-01-30PDF 302 KB
External PhotosExternal Photos2006-01-30PDF 549 KB
FCC ID LabelID Label/Location Info2006-01-30PDF 183 KB
Setup PhotosTest Setup Photos2006-01-30PDF 1.7 MB
Test ReportTest Report2006-01-30PDF 841.5 KB
Request for ConfidentialityCover Letter(s)2006-01-30PDF 56 KB
Block Diagram Metadata onlyBlock DiagramPDF 580 KB
Schematics Metadata onlySchematicsPDF 576.3 KB
Operational Description Metadata onlyOperational DescriptionPDF 463.5 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 463.5 KB

Application Information

Application IDJlYueTMk3hOJE/Zr+Z06LQ==
Final Action Date2006-01-30
Application PurposeOriginal Equipment
Applicant FRN0009878307
ModelM900RFX
Frequency Range896-901 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionReFlex Telemetry Device
Responsible PartyDavid Kim, General Manager, davidkim@hunetec.com , 82-31-737-0850
Test FirmKi Hong Nam, ONETECH Corp., kihong.nam@onetech.co.kr , 82-31-799-9580
TCB Emailmike.kuo@ccsemc.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
JlYueTMk3hOJE/Zr+Z06LQ==2006-01-30Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
896-901 MHz0.991ppm8K17F1D9
901-902 MHz0.991ppm8K17F1D24D

Grants

TCB Grant - Application JlYueTMk3hOJE/Zr+Z06LQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 01/30/2006

Application Dated: 01/30/2006
Hunetec Co., Ltd
RM612, Starwood Plaza, 5439-1, Sangdaewon-Dong
Jungwon-Gu
Sungnam-City, Gyeonggi-Do, 462-120
South Korea
 
Attention: David Kim , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RNGM900RFX
Name of Grantee:  Hunetec Co., Ltd
Equipment Class: PCS Licensed Transmitter
Notes: ReFlex Telemetry Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 0.99 1.0  PM 8K17F1D
90 896.0  -  901.0 0.99 1.0  PM 8K17F1D

Output power listed is ERP. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application JlYueTMk3hOJE/Zr+Z06LQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hunetec Co., Ltd
RM612, Starwood Plaza, 5439-1, Sangdaewon-Dong Jungwon-Gu
Sungnam-City, Gyeonggi-Do, 462-120
South Korea
  Date of Grant: 01/30/2006

Application Dated: 01/30/2006
 
Attention: David Kim , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RNGM900RFX
Name of Grantee:  Hunetec Co., Ltd
Equipment Class: PCS Licensed Transmitter
Notes: ReFlex Telemetry Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 0.99 1.0  PM 8K17F1D
90 896.0  -  901.0 0.99 1.0  PM 8K17F1D

Output power listed is ERP. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: