FCC ID ROSGTM601W

2G/3G LGA Module

by Remote Diagnostic Technologies Ltd.

Grantee Code: ROS   Product Code: GTM601W
Latest application date: 2013-05-17

FCC ID Device Details

FCC IDROSGTM601W
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeROS
Product CodeGTM601W
Applicant BusinessRemote Diagnostic Technologies Ltd. 🇬🇧
Related Domains rdtltd.com
Equipment Class2G/3G LGA Module
Test FirmUL VS Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzClass II permissive change or modification of presently authorized equipment2013-05-17
824.2-848.8 MHzChange in identification of presently authorized equipment. Original FCC ID: NCMOMO6012 Grant Date: 03/09/20112013-04-23

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2013-05-17PDF 1.3 MB
External PhotosExternal Photos2013-04-23PDF 348.9 KB
LabelID Label/Location Info2013-05-17PDF 58.6 KB
LabelID Label/Location Info2013-04-23PDF 348.9 KB
RF EMC Report 01Test Report2013-05-17PDF 345.3 KB
RF EMC Report 02Test Report2013-05-17PDF 405.6 KB
RF EMC Report 03Test Report2013-05-17PDF 937.2 KB
RF EMC Report 04Test Report2013-05-17PDF 921 KB
RF EMC Report 05Test Report2013-05-17PDF 686.2 KB
SAR Report part 1RF Exposure Info2013-05-17PDF 2 MB
SAR Report part 2RF Exposure Info2013-05-17PDF 294.5 KB
SAR Report part 3RF Exposure Info2013-05-17PDF 365.7 KB
Power and FCC ID discrepanciesAttestation Statements2013-05-17PDF 66 KB
C2PC Cover LetterCover Letter(s)2013-05-17PDF 49.9 KB
Letter from applicantCover Letter(s)2013-04-23PDF 64.3 KB
Letter from original GranteeCover Letter(s)2013-04-23PDF 309.4 KB

Application Information

Application IDs8crjxGOvT+eXbwdX4Jjrw==
Final Action Date2013-05-17
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0009959644
ModelGTM601W
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device Description2G/3G LGA Module
Responsible PartyChris Hannan, Product Validation Manager, chris@rdtltd.com , +44 1256 362 400
Test FirmJohn Newell, UL VS Ltd, john.newell@ul.com , 00-44-1256-312000
TCB Emailhotline@acbcert.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is ERP for Part 22 and EIRP for Part 24. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Class 2 Permissive Change to allow portable installation in the RDT Tempus Pro. Highest reported SAR values are: 0.02 W/kg body-worn and 0.11 W/kg simultaneous transmission.

Applications

Application IDDatePurpose
s8crjxGOvT+eXbwdX4Jjrw==2013-05-17Class II permissive change or modification of presently authorized equipment
Y9Vvkm0Oag8KThf+bHl32A==2013-04-23Change in identification of presently authorized equipment. Original FCC ID: NCMOMO6012 Grant Date: 03/09/2011
+o/8q0mr3ltmVzMOF782Iw==2013-04-23Change in identification of presently authorized equipment. Original FCC ID: NCMOMO6012 Grant Date: 12/10/2010

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz2.8872.5ppm246KGXW22HBC
824.2-848.8 MHz1.8492.5ppm249KG7W22HBC
826.4-846.6 MHz0.3232.5ppm4M17F9W22HBC
1850.2-1909.8 MHz0.3232.5ppm247KGXW24EBC
1850.2-1909.8 MHz0.2942.5ppm248KG7W24EBC
1852.4-1907.6 MHz0.1132.5ppm4M17F9W24EBC

Grants

TCB Grant - Application Y9Vvkm0Oag8KThf+bHl32A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 04/23/2013

Application Dated: 04/23/2013
Remote Diagnostic Technologies Ltd.
The Avenue
Farleigh Wallop
Basingstoke, Hants, RG25 2HT
United Kingdom
 
Attention: Chris Hannan , Product Validation Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ROSGTM601W
Name of Grantee:  Remote Diagnostic Technologies Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: 2G/3G LGA Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 2.887 2.5  PM 246KGXW
BC 22H 824.2  -  848.8 1.849 2.5  PM 249KG7W
BC 22H 826.4  -  846.6 0.323 2.5  PM 4M17F9W
BC 24E 1850.2  -  1909.8 0.323 2.5  PM 247KGXW
BC 24E 1850.2  -  1909.8 0.294 2.5  PM 248KG7W
BC 24E 1852.4  -  1907.6 0.113 2.5  PM 4M17F9W

Power Output is ERP for Part 22 and EIRP for Part 24. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application Y9Vvkm0Oag8KThf+bHl32A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Remote Diagnostic Technologies Ltd.
The Avenue Farleigh Wallop
Basingstoke, Hants, RG25 2HT
United Kingdom
  Date of Grant: 04/23/2013

Application Dated: 04/23/2013
 
Attention: Chris Hannan , Product Validation Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ROSGTM601W
Name of Grantee:  Remote Diagnostic Technologies Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: 2G/3G LGA Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 2.887 2.5  PM 246KGXW
BC 22H 824.2  -  848.8 1.849 2.5  PM 249KG7W
BC 22H 826.4  -  846.6 0.323 2.5  PM 4M17F9W
BC 24E 1850.2  -  1909.8 0.323 2.5  PM 247KGXW
BC 24E 1850.2  -  1909.8 0.294 2.5  PM 248KG7W
BC 24E 1852.4  -  1907.6 0.113 2.5  PM 4M17F9W

Power Output is ERP for Part 22 and EIRP for Part 24. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

TCB Grant - Application s8crjxGOvT+eXbwdX4Jjrw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 05/17/2013

Application Dated: 05/17/2013
Remote Diagnostic Technologies Ltd.
The Avenue
Farleigh Wallop
Basingstoke, Hants, RG25 2HT
United Kingdom
 
Attention: Chris Hannan , Product Validation Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ROSGTM601W
Name of Grantee:  Remote Diagnostic Technologies Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: 2G/3G LGA Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 2.887 2.5  PM 246KGXW
BC 22H 824.2  -  848.8 1.849 2.5  PM 249KG7W
BC 22H 826.4  -  846.6 0.323 2.5  PM 4M17F9W
BC 24E 1850.2  -  1909.8 0.323 2.5  PM 247KGXW
BC 24E 1850.2  -  1909.8 0.294 2.5  PM 248KG7W
BC 24E 1852.4  -  1907.6 0.113 2.5  PM 4M17F9W

Power Output is ERP for Part 22 and EIRP for Part 24. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Class 2 Permissive Change to allow portable installation in the RDT Tempus Pro. Highest reported SAR values are: 0.02 W/kg body-worn and 0.11 W/kg simultaneous transmission.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application s8crjxGOvT+eXbwdX4Jjrw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Remote Diagnostic Technologies Ltd.
The Avenue Farleigh Wallop
Basingstoke, Hants, RG25 2HT
United Kingdom
  Date of Grant: 05/17/2013

Application Dated: 05/17/2013
 
Attention: Chris Hannan , Product Validation Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ROSGTM601W
Name of Grantee:  Remote Diagnostic Technologies Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: 2G/3G LGA Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 2.887 2.5  PM 246KGXW
BC 22H 824.2  -  848.8 1.849 2.5  PM 249KG7W
BC 22H 826.4  -  846.6 0.323 2.5  PM 4M17F9W
BC 24E 1850.2  -  1909.8 0.323 2.5  PM 247KGXW
BC 24E 1850.2  -  1909.8 0.294 2.5  PM 248KG7W
BC 24E 1852.4  -  1907.6 0.113 2.5  PM 4M17F9W

Power Output is ERP for Part 22 and EIRP for Part 24. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Class 2 Permissive Change to allow portable installation in the RDT Tempus Pro. Highest reported SAR values are: 0.02 W/kg body-worn and 0.11 W/kg simultaneous transmission.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

TCB Grant - Application +o/8q0mr3ltmVzMOF782Iw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 04/23/2013

Application Dated: 04/23/2013
Remote Diagnostic Technologies Ltd.
The Avenue
Farleigh Wallop
Basingstoke, Hants, RG25 2HT
United Kingdom
 
Attention: Chris Hannan , Product Validation Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ROSGTM601W
Name of Grantee:  Remote Diagnostic Technologies Ltd.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: 2G/3G LGA Module
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B  - 

This device also contains a licensed transmitter.

EAS Grant - Application +o/8q0mr3ltmVzMOF782Iw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Remote Diagnostic Technologies Ltd.
The Avenue Farleigh Wallop
Basingstoke, Hants, RG25 2HT
United Kingdom
  Date of Grant: 04/23/2013

Application Dated: 04/23/2013
 
Attention: Chris Hannan , Product Validation Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ROSGTM601W
Name of Grantee:  Remote Diagnostic Technologies Ltd.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: 2G/3G LGA Module
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B  - 

This device also contains a licensed transmitter.



Mail To: