Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Class II permissive change or modification of presently authorized equipment | 2013-06-25 |
| 824.2-848.8 MHz | Change in identification of presently authorized equipment. Original FCC ID: QIPMC55I Grant Date: 01/23/2008 | 2012-12-24 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Tempus IC Host User-Operator Manual | Users Manual | 2013-06-25 | PDF 2.1 MB |
| Host Internal photos Part 1 | Internal Photos | 2013-06-25 | PDF 3.2 MB |
| Host Internal photos Part 2 | Internal Photos | 2013-06-25 | PDF 4.3 MB |
| Host External Photos | External Photos | 2013-06-25 | PDF 364.1 KB |
| External Photos | External Photos | 2012-12-24 | PDF 30.8 KB |
| FCC label detail | ID Label/Location Info | 2013-06-25 | PDF 58.9 KB |
| Label location | ID Label/Location Info | 2013-06-25 | PDF 1.5 MB |
| Label Detail | ID Label/Location Info | 2012-12-24 | PDF 28.2 KB |
| AC Mains CE Test Set Up Photo | Test Setup Photos | 2013-06-25 | PDF 1 MB |
| Idle Mode RSE Test Set Up Photo | Test Setup Photos | 2013-06-25 | PDF 122.9 KB |
| TX Co-location RSE Test Set Up Photo | Test Setup Photos | 2013-06-25 | PDF 422.9 KB |
| Colocation Test Report | Test Report | 2013-06-25 | PDF 625.5 KB |
| Part 15B Test Report | Test Report | 2013-06-25 | PDF 694.9 KB |
| SAR Test Report | RF Exposure Info | 2013-06-25 | PDF 1.8 MB |
| Power Level Difference attestation | Attestation Statements | 2013-06-25 | PDF 45.8 KB |
| Agency Letter | Cover Letter(s) | 2013-06-25 | PDF 54.3 KB |
| Antenna location | Cover Letter(s) | 2013-06-25 | PDF 202.4 KB |
| C2PC request letter | Cover Letter(s) | 2013-06-25 | PDF 65.6 KB |
| Confidentiality Request | Cover Letter(s) | 2013-06-25 | PDF 45.7 KB |
| TCB SAR Test Plan Cover Letter | Cover Letter(s) | 2013-06-25 | PDF 114.6 KB |
| Agency Letter | Cover Letter(s) | 2012-12-24 | PDF 767.5 KB |
| Module Manufacturer Authorisation Letter | Cover Letter(s) | 2012-12-24 | PDF 403.2 KB |
| Request For Grant Change | Cover Letter(s) | 2012-12-24 | PDF 897.5 KB |
| SAR Test Plan | RF Exposure Info | 2013-06-25 | PDF 96.1 KB |
Application Information
| Application ID | mVZKIphxtb0OMBkb9kgddg== |
|---|---|
| Final Action Date | 2013-06-25 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0009959644 |
| Model | TEMPUSIC-2 |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Quadband GSM/GPRS Module |
| Responsible Party | Chris Hannan, Product Validation Manager, chris@rdtltd.com |
| Technical Contact | Leigh Cornock, Remote Diagnostic Technologies Ltd, lcornock@rdtltd.com |
| Non-Technical Contact | Chris Hannon, Remote Diagnostic Technologies Ltd, channon@rdtltd.com |
| Test Firm | John Newell, UL VS Ltd, john.newell@ul.com |
| TCB Email | certification@ul.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Single Modular Approval |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Modular Transmitter. Power Output listed is peak conducted. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. For mobile operating configurations the antenna gain, including cable loss, must not exceed 2.89 dBi at 1900 MHz and 1.33 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance. For fixed operating configurations the final device including antenna gain and cable loss, must fulfil the requirements of 1.1307 of the rules for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. The final product operating with this transmitter must include operating instructions and applicable warnings, as described in this filing, for end users and installers to satisfy RF exposure compliance requirements. OEM integrators must be informed of the specific requirements. This permissive change provides for co-location with specific transmitters in a portable configuration within the RDT Tempus IC as documented in this filing. SAR compliance for lap-held operating conditions is limited to the specific operating configuration tested for this filing; other configurations require separate evaluation. The highest reported SAR for lap-held and simultaneous transmission exposure conditions are <0.10 W/kg and <0.10 W/kg respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| mVZKIphxtb0OMBkb9kgddg== | 2013-06-25 | Class II permissive change or modification of presently authorized equipment |
| PgqFNSRm/8szfV3I0g4J4Q== | 2012-12-24 | Change in identification of presently authorized equipment. Original FCC ID: QIPMC55I Grant Date: 01/23/2008 |
Equipment Authorization
Grants
TCB Grant - Application PgqFNSRm/8szfV3I0g4J4Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL VS Ltd Unit 3 Horizon, Wade Road, Kingsland Business Park, Basingstoke, RG24 8AH United Kingdom |
Date of Grant: 12/24/2012 Application Dated: 12/24/2012 |
| Remote Diagnostic Technologies Ltd. |
| The Avenue |
| Farleigh Wallop |
| Basingstoke, Hants, RG25 2HT United Kingdom |
| Attention: Chris Hannan , Product Validation Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ROSTEMPUSIC-2 |
| Name of Grantee: | Remote Diagnostic Technologies Ltd. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Quadband GSM/GPRS Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.807 | 0.0027 PM | 300KGXW | |
| 24E | 1850.2 - 1909.8 | 1.026 | 0.0024 PM | 300KGXW |
| Modular Transmitter. Power Output listed is peak conducted. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. For mobile operating configurations the antenna gain, including cable loss, must not exceed 2.89 dBi at 1900 MHz and 1.33 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance. For fixed operating configurations the final device including antenna gain and cable loss, must fulfil the requirements of 1.1307 of the rules for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. The final product operating with this transmitter must include operating instructions and applicable warnings, as described in this filing, for end users and installers to satisfy RF exposure compliance requirements. OEM integrators must be informed of the specific requirements. |
EAS Grant - Application PgqFNSRm/8szfV3I0g4J4Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Remote Diagnostic Technologies Ltd. The Avenue Farleigh Wallop Basingstoke, Hants, RG25 2HT United Kingdom |
Date of Grant: 12/24/2012 Application Dated: 12/24/2012 |
| Attention: Chris Hannan , Product Validation Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ROSTEMPUSIC-2 |
| Name of Grantee: | Remote Diagnostic Technologies Ltd. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Quadband GSM/GPRS Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.807 | 0.0027 PM | 300KGXW | |
| 24E | 1850.2 - 1909.8 | 1.026 | 0.0024 PM | 300KGXW |
| Modular Transmitter. Power Output listed is peak conducted. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. For mobile operating configurations the antenna gain, including cable loss, must not exceed 2.89 dBi at 1900 MHz and 1.33 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance. For fixed operating configurations the final device including antenna gain and cable loss, must fulfil the requirements of 1.1307 of the rules for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. The final product operating with this transmitter must include operating instructions and applicable warnings, as described in this filing, for end users and installers to satisfy RF exposure compliance requirements. OEM integrators must be informed of the specific requirements. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL VS Ltd Unit 3 Horizon, Wade Road, Kingsland Business Park, Basingstoke, RG24 8AH United Kingdom |
Date of Grant: 06/25/2013 Application Dated: 06/25/2013 |
| Remote Diagnostic Technologies Ltd. |
| The Avenue |
| Farleigh Wallop |
| Basingstoke, Hants, RG25 2HT United Kingdom |
| Attention: Chris Hannan , Product Validation Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ROSTEMPUSIC-2 |
| Name of Grantee: | Remote Diagnostic Technologies Ltd. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Quadband GSM/GPRS Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22 | 824.2 - 848.8 | 1.807 | 0.0027 PM | 300KGXW | |
| 24E | 1850.2 - 1909.8 | 1.026 | 0.0024 PM | 300KGXW |
| Modular Transmitter. Power Output listed is peak conducted. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. For mobile operating configurations the antenna gain, including cable loss, must not exceed 2.89 dBi at 1900 MHz and 1.33 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance. For fixed operating configurations the final device including antenna gain and cable loss, must fulfil the requirements of 1.1307 of the rules for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. The final product operating with this transmitter must include operating instructions and applicable warnings, as described in this filing, for end users and installers to satisfy RF exposure compliance requirements. OEM integrators must be informed of the specific requirements. This permissive change provides for co-location with specific transmitters in a portable configuration within the RDT Tempus IC as documented in this filing. SAR compliance for lap-held operating conditions is limited to the specific operating configuration tested for this filing; other configurations require separate evaluation. The highest reported SAR for lap-held and simultaneous transmission exposure conditions are <0.10 W/kg and <0.10 W/kg respectively. |
EAS Grant - Application mVZKIphxtb0OMBkb9kgddg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Remote Diagnostic Technologies Ltd. The Avenue Farleigh Wallop Basingstoke, Hants, RG25 2HT United Kingdom |
Date of Grant: 06/25/2013 Application Dated: 06/25/2013 |
| Attention: Chris Hannan , Product Validation Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ROSTEMPUSIC-2 |
| Name of Grantee: | Remote Diagnostic Technologies Ltd. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Quadband GSM/GPRS Module |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22 | 824.2 - 848.8 | 1.807 | 0.0027 PM | 300KGXW | |
| 24E | 1850.2 - 1909.8 | 1.026 | 0.0024 PM | 300KGXW |
| Modular Transmitter. Power Output listed is peak conducted. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. For mobile operating configurations the antenna gain, including cable loss, must not exceed 2.89 dBi at 1900 MHz and 1.33 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance. For fixed operating configurations the final device including antenna gain and cable loss, must fulfil the requirements of 1.1307 of the rules for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. The final product operating with this transmitter must include operating instructions and applicable warnings, as described in this filing, for end users and installers to satisfy RF exposure compliance requirements. OEM integrators must be informed of the specific requirements. This permissive change provides for co-location with specific transmitters in a portable configuration within the RDT Tempus IC as documented in this filing. SAR compliance for lap-held operating conditions is limited to the specific operating configuration tested for this filing; other configurations require separate evaluation. The highest reported SAR for lap-held and simultaneous transmission exposure conditions are <0.10 W/kg and <0.10 W/kg respectively. |