FCC ID RPJ01GM100-1
Blood Glucose Meter
by SD Biosensor, Inc.
Grantee Code: RPJ Product Code: 01GM1001
Latest application date: 2023-08-01
FCC ID Device Details
| FCC ID | RPJ01GM100-1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | RPJ |
| Product Code | 01GM1001 |
| Applicant Business | SD Biosensor, Inc. 🇰🇷 |
| Related Domains | |
| Equipment Class | Blood Glucose Meter |
| Test Firm | DT&C; Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2023-08-01 |
| 2402-2480 MHz | Original Equipment | 2023-08-01 |
| 5180-5240 MHz | Original Equipment | 2023-08-01 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2024-01-28 | PDF 5.3 MB |
| Internal Photos Part 1 | Internal Photos | 2024-01-28 | PDF 4.6 MB |
| Internal Photos Part 2 | Internal Photos | 2024-01-28 | PDF 3 MB |
| External Photos | External Photos | 2024-01-28 | PDF 2.5 MB |
| Label Sample and Location | ID Label/Location Info | 2023-08-01 | PDF 159.8 KB |
| Test Setup Photos BT | Test Setup Photos | 2024-01-28 | PDF 4.8 MB |
| Test Setup Photos DFS | Test Setup Photos | 2024-01-28 | PDF 616.8 KB |
| Antenna Specification | Test Report | 2023-08-01 | PDF 1.6 MB |
| Test Report BT | Test Report | 2023-08-01 | PDF 5.2 MB |
| Test Report DFS | Test Report | 2023-08-01 | PDF 1.7 MB |
| Test Report LE | Test Report | 2023-08-01 | PDF 2.3 MB |
| Test Report WLAN | Test Report | 2023-08-01 | PDF 5.6 MB |
| Test Report WLAN Part 1 | Test Report | 2023-08-01 | PDF 4.5 MB |
| Test Report WLAN Part 2 | Test Report | 2023-08-01 | PDF 3.4 MB |
| Attestation Statements Part 2.911(d)(7) | Attestation Statements | 2023-08-01 | PDF 290.9 KB |
| Attstn Stmt Part 2.911(d)(5)(i)&(ii) | Attestation Statements | 2023-08-01 | PDF 124.2 KB |
| Authorization Letter | Cover Letter(s) | 2023-08-01 | PDF 30.9 KB |
| Confidentiality Request Letter | Cover Letter(s) | 2023-08-01 | PDF 35.2 KB |
| SAR Test Exclusion Considerations | RF Exposure Info | 2023-08-01 | PDF 70.8 KB |
| Block Diagram Metadata only | Block Diagram | PDF 184.7 KB | |
| Part Location Schematics Metadata only | Schematics | PDF 2.2 MB | |
| Schematics Metadata only | Schematics | PDF 788.8 KB | |
| Operational Description Part 1 Metadata only | Operational Description | PDF 3 MB | |
| Operational Description Part 2 Metadata only | Operational Description | PDF 4.9 MB | |
| Op Des Software Security Metadata only | SDR Software/Security Inf | PDF 79.5 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 151.2 KB |
Application Information
| Application ID | gkTFpbZnRekVHV+E9BOD0A== |
|---|---|
| Final Action Date | 2023-08-01 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0022339899 |
| Model | 01GM100-1 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | Blood Glucose Meter |
| Responsible Party | Hyolim Park, Senior Manager, hlpark@sdbiosensor.com |
| Test Firm | Lee Sang-Wook, DT&C; Co., Ltd., qa@dtnc.net |
| TCB Email | tei@timcoengr.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 01/28/2024 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| gkTFpbZnRekVHV+E9BOD0A== | 2023-08-01 | Original Equipment |
| J1tr8JsvGsCDsivCVTp1aQ== | 2023-08-01 | Original Equipment |
| 7EY9OSLnXkPMAO3Q328Mhw== | 2023-08-01 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application J1tr8JsvGsCDsivCVTp1aQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 08/01/2023 Application Dated: 08/01/2023 |
| SD Biosensor, Inc. |
| C-4th&5th, 16, Deogyeong-daero, 1556beon-gil, |
| Yeongtong-gu, |
| Suwon-si, Gyeonggi-do, 443-813 South Korea |
| Attention: Hyolim Park , Senior Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RPJ01GM100-1 |
| Name of Grantee: | SD Biosensor, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Blood Glucose Meter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0016 | |||
| 15C | 2412.0 - 2462.0 | 0.0592 |
EAS Grant - Application J1tr8JsvGsCDsivCVTp1aQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SD Biosensor, Inc. C-4th&5th, 16, Deogyeong-daero, 1556beon-gil, Yeongtong-gu, Suwon-si, Gyeonggi-do, 443-813 South Korea |
Date of Grant: 08/01/2023 Application Dated: 08/01/2023 |
| Attention: Hyolim Park , Senior Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RPJ01GM100-1 |
| Name of Grantee: | SD Biosensor, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Blood Glucose Meter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0016 | |||
| 15C | 2412.0 - 2462.0 | 0.0592 |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 08/01/2023 Application Dated: 08/01/2023 |
| SD Biosensor, Inc. |
| C-4th&5th, 16, Deogyeong-daero, 1556beon-gil, |
| Yeongtong-gu, |
| Suwon-si, Gyeonggi-do, 443-813 South Korea |
| Attention: Hyolim Park , Senior Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RPJ01GM100-1 |
| Name of Grantee: | SD Biosensor, Inc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Blood Glucose Meter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0025 |
EAS Grant - Application gkTFpbZnRekVHV+E9BOD0A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SD Biosensor, Inc. C-4th&5th, 16, Deogyeong-daero, 1556beon-gil, Yeongtong-gu, Suwon-si, Gyeonggi-do, 443-813 South Korea |
Date of Grant: 08/01/2023 Application Dated: 08/01/2023 |
| Attention: Hyolim Park , Senior Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RPJ01GM100-1 |
| Name of Grantee: | SD Biosensor, Inc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Blood Glucose Meter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0025 |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 08/01/2023 Application Dated: 08/01/2023 |
| SD Biosensor, Inc. |
| C-4th&5th, 16, Deogyeong-daero, 1556beon-gil, |
| Yeongtong-gu, |
| Suwon-si, Gyeonggi-do, 443-813 South Korea |
| Attention: Hyolim Park , Senior Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RPJ01GM100-1 |
| Name of Grantee: | SD Biosensor, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Blood Glucose Meter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15E | 5180.0 - 5240.0 | 0.0006 | |||
| 15E | 5260.0 - 5320.0 | 0.0005 | |||
| 15E | 5500.0 - 5720.0 | 0.0005 | |||
| 15E | 5745.0 - 5825.0 | 0.0002 |
EAS Grant - Application 7EY9OSLnXkPMAO3Q328Mhw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SD Biosensor, Inc. C-4th&5th, 16, Deogyeong-daero, 1556beon-gil, Yeongtong-gu, Suwon-si, Gyeonggi-do, 443-813 South Korea |
Date of Grant: 08/01/2023 Application Dated: 08/01/2023 |
| Attention: Hyolim Park , Senior Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RPJ01GM100-1 |
| Name of Grantee: | SD Biosensor, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Blood Glucose Meter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15E | 5180.0 - 5240.0 | 0.0006 | |||
| 15E | 5260.0 - 5320.0 | 0.0005 | |||
| 15E | 5500.0 - 5720.0 | 0.0005 | |||
| 15E | 5745.0 - 5825.0 | 0.0002 |
| Mail To: |