FCC ID RSNFORCE3-PSB
Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS
by Cellphone-Mate Inc. dba SureCall
Grantee Code: RSN Product Code: FORCE3PSB
Latest application date: 2015-06-17
FCC ID Device Details
| FCC ID | RSNFORCE3-PSB |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | RSN |
| Product Code | FORCE3PSB |
| Applicant Business | Cellphone-Mate Inc. dba SureCall 🇺🇸 |
| Related Domains | |
| Equipment Class | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Test Firm | CKC Laboratories, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 758-768 MHz | Original Equipment | 2015-06-17 |
| 817-824 MHz | Original Equipment | 2015-06-17 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual Metadata only | Users Manual | 2015-06-17 | PDF 689.2 KB |
| Users Manual v2 | Users Manual | 2015-06-17 | PDF 1 MB |
| Internal Photos | Internal Photos | 2015-06-17 | PDF 369.5 KB |
| Internal Photos | Internal Photos | 2015-06-17 | PDF 979 KB |
| External Photos | External Photos | 2015-06-17 | PDF 293.2 KB |
| ID Label 2 | ID Label/Location Info | 2015-06-17 | PDF 66.2 KB |
| ID Label Location | ID Label/Location Info | 2015-06-17 | PDF 109.4 KB |
| ID Labell Metadata only | ID Label/Location Info | 2015-06-17 | PDF 117.9 KB |
| ID label Metadata only | ID Label/Location Info | 2015-06-17 | PDF 117.9 KB |
| Test Report Vol1 Part 1 | Test Report | 2015-06-17 | PDF 3.9 MB |
| Test Report Vol1 Part 2 | Test Report | 2015-06-17 | PDF 3.4 MB |
| Test Report Vol2 | Test Report | 2015-06-17 | PDF 5 MB |
| Booster Attestation Letter | Cover Letter(s) | 2015-06-17 | PDF 122.9 KB |
| Authorization Letter | Cover Letter(s) | 2015-06-17 | PDF 284.4 KB |
| Confidentiality Request | Cover Letter(s) | 2015-06-17 | PDF 288.1 KB |
| RF Exposure | RF Exposure Info | 2015-06-17 | PDF 603.3 KB |
| RF Exposure Info | RF Exposure Info | 2015-06-17 | PDF 766.5 KB |
| Block Diagram Metadata only | Block Diagram | PDF 115.1 KB | |
| Schematics Metadata only | Schematics | PDF 654.5 KB | |
| Operational Description Metadata only | Operational Description | PDF 369.5 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 187.6 KB | |
| Tune up Procedure Metadata only | Parts List/Tune Up Info | PDF 53.8 KB | |
| Tuneup Procedure Metadata only | Parts List/Tune Up Info | PDF 53.8 KB |
Application Information
| Application ID | RPKHHSel/tmlhaCnl5KE0g== |
|---|---|
| Final Action Date | 2015-06-17 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0010188936 |
| Model | FORCE3-PSB |
| Frequency Range | 758-768 MHz |
| Equipment Class | B9B - Part 90 Class B Industrial Booster (non-SMR) |
| Device Description | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Responsible Party | Dennis Findley, Director of Operations, dennis@surecall.com |
| Agent | Michelle Michelle Michelle, CKC Certification Services, LLC, info@ckccertification.com |
| Technical Contact | Dennis Findley, Cellphone Mate, Inc., dennis@cellphone-mate.com |
| Test Firm | Steve Behm, CKC Laboratories, Inc., steve.behm@ckc.com |
| TCB Email | info@ckccertification.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| RPKHHSel/tmlhaCnl5KE0g== | 2015-06-17 | Original Equipment |
| 0cDT3qeH/4GdNDKDWWu5BQ== | 2015-06-17 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 758-768 MHz | 0.61 | Amp | G7D | 9 | PF |
| 769-775 MHz | 0.52 | Amp | F1D | 9 | |
| 799-805 MHz | 0.5 | Amp | F1D | 9 | |
| 806-817 MHz | 0.43 | Amp | F1D | 9 | |
| 806-817 MHz | 0.42 | Amp | F3E | 9 | |
| 817-824 MHz | 0.35 | Amp | D1W | 90S | |
| 851-862 MHz | 0.49 | Amp | F1D | 9 | |
| 851-862 MHz | 0.49 | Amp | F3E | 9 | |
| 862-869 MHz | 0.35 | Amp | D1W | 90S | |
| 896-901 MHz | 0.4 | Amp | F3E | 90S | |
| 896-901 MHz | 0.4 | Amp | F3E | 9 | |
| 935-940 MHz | 0.49 | Amp | F3E | 9 | |
| 935-940 MHz | 0.49 | Amp | F3E | 90S |
Grants
TCB Grant - Application RPKHHSel/tmlhaCnl5KE0g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CKC Certification Services, LLC 5046 Sierra Pines Mariposa, CA 95338 |
Date of Grant: 06/17/2015 Application Dated: 05/26/2015 |
| Cellphone-Mate Inc. dba SureCall |
| 48346 Milmont Drive |
| Fremont, CA 94538 |
| Attention: Dennis Findley , Director of Operations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RSNFORCE3-PSB |
| Name of Grantee: | Cellphone-Mate Inc. dba SureCall |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 788.0 - 798.0 | 0.39 | Amp | G7D |
| 90 | 799.0 - 805.0 | 0.5 | Amp | F1D | |
| PF | 90 | 758.0 - 768.0 | 0.61 | Amp | G7D |
| 90 | 769.0 - 775.0 | 0.52 | Amp | F1D | |
| 90 | 806.0 - 817.0 | 0.43 | Amp | F1D | |
| 90 | 851.0 - 862.0 | 0.49 | Amp | F1D | |
| 90 | 806.0 - 817.0 | 0.42 | Amp | F3E | |
| 90 | 851.0 - 862.0 | 0.49 | Amp | F3E | |
| 90 | 896.0 - 901.0 | 0.4 | Amp | F3E | |
| 90 | 935.0 - 940.0 | 0.49 | Amp | F3E |
| Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
| PF: | Transmitter approved for Public Safety Broadband |
EAS Grant - Application RPKHHSel/tmlhaCnl5KE0g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Cellphone-Mate Inc. dba SureCall 48346 Milmont Drive Fremont, CA 94538 United States |
Date of Grant: 06/17/2015 Application Dated: 05/26/2015 |
| Attention: Dennis Findley , Director of Operations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RSNFORCE3-PSB |
| Name of Grantee: | Cellphone-Mate Inc. dba SureCall |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 788.0 - 798.0 | 0.39 | Amp | G7D |
| 90 | 799.0 - 805.0 | 0.5 | Amp | F1D | |
| PF | 90 | 758.0 - 768.0 | 0.61 | Amp | G7D |
| 90 | 769.0 - 775.0 | 0.52 | Amp | F1D | |
| 90 | 806.0 - 817.0 | 0.43 | Amp | F1D | |
| 90 | 851.0 - 862.0 | 0.49 | Amp | F1D | |
| 90 | 806.0 - 817.0 | 0.42 | Amp | F3E | |
| 90 | 851.0 - 862.0 | 0.49 | Amp | F3E | |
| 90 | 896.0 - 901.0 | 0.4 | Amp | F3E | |
| 90 | 935.0 - 940.0 | 0.49 | Amp | F3E |
| Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
| PF: | Transmitter approved for Public Safety Broadband |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CKC Certification Services, LLC 5046 Sierra Pines Mariposa, CA 95338 |
Date of Grant: 06/17/2015 Application Dated: 05/26/2015 |
| Cellphone-Mate Inc. dba SureCall |
| 48346 Milmont Drive |
| Fremont, CA 94538 |
| Attention: Dennis Findley , Director of Operations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RSNFORCE3-PSB |
| Name of Grantee: | Cellphone-Mate Inc. dba SureCall |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90S | 817.0 - 824.0 | 0.35 | Amp | D1W | |
| 90S | 862.0 - 869.0 | 0.35 | Amp | D1W | |
| 90S | 896.0 - 901.0 | 0.4 | Amp | F3E | |
| 90S | 935.0 - 940.0 | 0.49 | Amp | F3E |
| Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
EAS Grant - Application 0cDT3qeH/4GdNDKDWWu5BQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Cellphone-Mate Inc. dba SureCall 48346 Milmont Drive Fremont, CA 94538 United States |
Date of Grant: 06/17/2015 Application Dated: 05/26/2015 |
| Attention: Dennis Findley , Director of Operations |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RSNFORCE3-PSB |
| Name of Grantee: | Cellphone-Mate Inc. dba SureCall |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Multi-Band Public Safety 80db Amplifier Bi-Directional in-building DAS |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90S | 817.0 - 824.0 | 0.35 | Amp | D1W | |
| 90S | 862.0 - 869.0 | 0.35 | Amp | D1W | |
| 90S | 896.0 - 901.0 | 0.4 | Amp | F3E | |
| 90S | 935.0 - 940.0 | 0.49 | Amp | F3E |
| Power output is composite conducted for multichannel -operation. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Equipment is a Class B Industrial Booster and is restricted to installation as an In-building Distribution Antenna System (DAS). This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. |
| Mail To: |