FCC ID RV2ZMEM1075

Dual-Band GSM 850/1900 MHz Mobile Phone

by Ezze Mobile Tech., Inc.

Grantee Code: RV2   Product Code: ZMEM1075
Latest application date: 2007-03-07

FCC ID Device Details

FCC IDRV2ZMEM1075
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeRV2
Product CodeZMEM1075
Applicant BusinessEzze Mobile Tech., Inc. 🇰🇷
Related Domains ezzemobile.com cgckr.com
Equipment ClassDual-Band GSM 850/1900 MHz Mobile Phone
Test FirmHCT Co., LTD

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2007-03-07

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2007-03-07PDF 439.9 KB
Internal PhotosInternal Photos2007-03-07PDF 667 KB
External PhotosExternal Photos2007-03-07PDF 214.6 KB
ID LabelID Label/Location Info2007-03-07PDF 224.5 KB
SAR Test Setup PhotosTest Setup Photos2007-03-07PDF 1.2 MB
Test Setup PhotosTest Setup Photos2007-03-07PDF 307.6 KB
Annx to Test ReportTest Report2007-03-07PDF 287.4 KB
Test ReportTest Report2007-03-07PDF 291 KB
Authorization LetterCover Letter(s)2007-03-07PDF 17.9 KB
RF Exposure Warning StatementsCover Letter(s)2007-03-07PDF 16.4 KB
Request for ConfidentialityCover Letter(s)2007-03-07PDF 17.2 KB
SAR ReportRF Exposure Info2007-03-07PDF 2.9 MB

Application Information

Application IDAScFJwh0cLI4xbd0EXGWmw==
Final Action Date2007-03-07
Application PurposeOriginal Equipment
Applicant FRN0015133044
ModelZMEM1075
Frequency Range824.2-848.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionDual-Band GSM 850/1900 MHz Mobile Phone
Responsible PartyDaehan Ko, General Manager, douglas@ezzemobile.com , 82-2-519-7769
Technical ContactJoseph Chung, CGC Korea Inc., mjchung@cgckr.com , 82-31-632-0856-
Non-Technical ContactJoseph Chung, CGC Korea Inc., mjchung@cgckr.com , 82-31-632-0856-
Test FirmSang Lee, HCT Co., LTD, sjlee@HCT.co.kr , 82-31-645-6420
TCB EmailBrandhorst.dirk@phoenix-testlab.de
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is ERP for part 22 and EIRP for part 24. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 1.5 cm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are GSM 850 - Head: 0.78 W/kg and Body: 0.274 W/kg; GSM1900 - Head: 0.742 W/kg and Body: 0.264 W/kg.

Applications

Application IDDatePurpose
AScFJwh0cLI4xbd0EXGWmw==2007-03-07Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.9292.5ppm300KGXW22H
1850.2-1909.8 MHz0.5392.5ppm300KGXW24E

Grants

TCB Grant - Application AScFJwh0cLI4xbd0EXGWmw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 03/07/2007

Application Dated: 03/07/2007
Ezze Mobile Tech., Inc.
3rd Floor, Bubmusa Bldg., 151-31, Nonhyun-dong,
Kangnam-ku, Seoul, Korea
Seoul,
South Korea
 
Attention: Daehan Ko , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RV2ZMEM1075
Name of Grantee:  Ezze Mobile Tech., Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Dual-Band GSM 850/1900 MHz Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.929 2.5  PM 300KGXW
24E 1850.2  -  1909.8 0.539 2.5  PM 300KGXW

Power listed is ERP for part 22 and EIRP for part 24. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 1.5 cm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are GSM 850 - Head: 0.78 W/kg and Body: 0.274 W/kg; GSM1900 - Head: 0.742 W/kg and Body: 0.264 W/kg.

EAS Grant - Application AScFJwh0cLI4xbd0EXGWmw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ezze Mobile Tech., Inc.
3rd Floor, Bubmusa Bldg., 151-31, Nonhyun-dong, Kangnam-ku, Seoul, Korea
Seoul,
South Korea
  Date of Grant: 03/07/2007

Application Dated: 03/07/2007
 
Attention: Daehan Ko , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RV2ZMEM1075
Name of Grantee:  Ezze Mobile Tech., Inc.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Dual-Band GSM 850/1900 MHz Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.929 2.5  PM 300KGXW
24E 1850.2  -  1909.8 0.539 2.5  PM 300KGXW

Power listed is ERP for part 22 and EIRP for part 24. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 1.5 cm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are GSM 850 - Head: 0.78 W/kg and Body: 0.274 W/kg; GSM1900 - Head: 0.742 W/kg and Body: 0.264 W/kg.



Mail To:


EA598735