FCC ID RXUMX-C110

GSM/PCS Triple Band 900/1800/1900 MHz

by Maxon CIC Corp.

Grantee Code: RXU   Product Code: MXC110
Latest application date: 2004-04-28

FCC ID Device Details

FCC IDRXUMX-C110
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeRXU
Product CodeMXC110
Applicant BusinessMaxon CIC Corp. 🇰🇷
Related Domains maxoncic.com
Equipment ClassGSM/PCS Triple Band 900/1800/1900 MHz
Test FirmTUV SUD Product Service

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2004-04-28

Exhibits

DocumentTypeAvailableFile
MX C110 User guideUsers Manual2004-04-28PDF 1.8 MB
User guide warningUsers Manual2004-04-28PDF 53 KB
Internal photosInternal Photos2004-04-28PDF 793 KB
Test report photosInternal Photos2004-04-28PDF 528.5 KB
C110 imagesExternal Photos2004-04-28PDF 1.2 MB
External photosExternal Photos2004-04-28PDF 1.8 MB
Enclosure label photoID Label/Location Info2004-04-28PDF 198.3 KB
LabelID Label/Location Info2004-04-28PDF 95.4 KB
Part 24 test reportTest Report2004-04-28PDF 2.7 MB
Agents letterCover Letter(s)2004-04-28PDF 24.1 KB
Assessment letterRF Exposure Info2004-04-28PDF 53 KB
Confidentiality letterCover Letter(s)2004-04-28PDF 25.6 KB
SAR assessment reportRF Exposure Info2004-04-28PDF 1.2 MB
PCB assembly keypad Metadata onlySchematicsPDF 20.7 KB
PCB assembly main Metadata onlySchematicsPDF 121.6 KB
Schematics Metadata onlySchematicsPDF 525.5 KB
Circuit description Metadata onlyOperational DescriptionPDF 2.4 MB
Mechanical construction Metadata onlyOperational DescriptionPDF 459.4 KB
Hardware and Software Metadata onlyParts List/Tune Up InfoPDF 39.4 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 71.2 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 40.3 KB

Application Information

Application ID5HL/YGfS1I6Uplnuvw0YfQ==
Final Action Date2004-04-28
Application PurposeOriginal Equipment
Applicant FRN0010534170
ModelMX-C110
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionGSM/PCS Triple Band 900/1800/1900 MHz
Responsible PartyHyun-Koo Kang, Manager, hkkang@maxoncic.com , 82 2 3498 3045
Test FirmJensen Adams, TUV SUD Product Service, jensen.adams@tuv-sud.co.uk , 44-1489-558252
TCB EmailTom.Twynam@babt.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThe measured output power was radiated, the maximum reported body SAR was: 0.457 W/kg and the maximum reported head SAR was: 1.055 W/kg. This filing is only applicable for GSM 1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories which contain no metallic parts and maintain a minimum distance of 1.0 cm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. This mobile contains a 900 MHz and 1800 MHz function that is not operational in U.S. Territories.

Applications

Application IDDatePurpose
5HL/YGfS1I6Uplnuvw0YfQ==2004-04-28Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1850.2-1909.8 MHz1.0000000180.0000000000Hz300KGXW24E

Grants

TCB Grant - Application 5HL/YGfS1I6Uplnuvw0YfQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD BABT
Octagon House, Concorde Way, Segensworth North,
Fareham, PO15 5RL
United Kingdom
Date of Grant: 04/28/2004

Application Dated: 04/28/2004
Maxon CIC Corp.
Chongho Building, #7-61, Yangjae-Dong
Seocho-Ku
Seoul, 137-130
South Korea
 
Attention: Hyun-Koo Kang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RXUMX-C110
Name of Grantee:  Maxon CIC Corp.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: GSM/PCS Triple Band 900/1800/1900 MHz
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 1.0 180.0  Hz 300KGXW

The measured output power was radiated, the maximum reported body SAR was: 0.457 W/kg and the maximum reported head SAR was: 1.055 W/kg.

This filing is only applicable for GSM 1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories which contain no metallic parts and maintain a minimum distance of 1.0 cm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. This mobile contains a 900 MHz and 1800 MHz function that is not operational in U.S. Territories.


EAS Grant - Application 5HL/YGfS1I6Uplnuvw0YfQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Maxon CIC Corp.
Chongho Building, #7-61, Yangjae-Dong Seocho-Ku
Seoul, 137-130
South Korea
  Date of Grant: 04/28/2004

Application Dated: 04/28/2004
 
Attention: Hyun-Koo Kang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RXUMX-C110
Name of Grantee:  Maxon CIC Corp.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: GSM/PCS Triple Band 900/1800/1900 MHz
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 1.0 180.0  Hz 300KGXW

The measured output power was radiated, the maximum reported body SAR was: 0.457 W/kg and the maximum reported head SAR was: 1.055 W/kg.

This filing is only applicable for GSM 1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories which contain no metallic parts and maintain a minimum distance of 1.0 cm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. This mobile contains a 900 MHz and 1800 MHz function that is not operational in U.S. Territories.



Mail To: