FCC ID RXUSP210U2
SP210 U2 PTT UHF-H
by Maxon CIC Corp.
Grantee Code: RXU Product Code: SP210U2
Latest application date: 2005-05-05
FCC ID Device Details
| FCC ID | RXUSP210U2 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | RXU |
| Product Code | SP210U2 |
| Applicant Business | Maxon CIC Corp. 🇰🇷 |
| Related Domains | |
| Equipment Class | SP210 U2 PTT UHF-H |
| Test Firm | Rhein Tech Laboratories, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 440-470 MHz | Original Equipment | 2005-05-05 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Manual | Users Manual | 2005-05-05 | PDF 192.5 KB |
| User Manual | Users Manual | 2005-05-05 | PDF 143 KB |
| Internal Photos Pt 1 | Internal Photos | 2005-05-05 | PDF 3.3 MB |
| Internal Photos Pt 2 | Internal Photos | 2005-05-05 | PDF 2.8 MB |
| Internal Photos Pt 3 | Internal Photos | 2005-05-05 | PDF 2.1 MB |
| External Photos | External Photos | 2005-05-05 | PDF 3.3 MB |
| Labels | ID Label/Location Info | 2005-05-05 | PDF 1.7 MB |
| Antenna Specification | Operational Description | 2005-05-05 | PDF 70.5 KB |
| Test Photos | Test Setup Photos | 2005-05-05 | PDF 2.6 MB |
| Test Report | Test Report | 2005-05-05 | PDF 503.4 KB |
| Agency Authorization | Cover Letter(s) | 2005-05-05 | PDF 640 KB |
| Confidentiality Request | Cover Letter(s) | 2005-05-05 | PDF 500.7 KB |
| Correspondence Response | Cover Letter(s) | 2005-05-05 | PDF 21.3 KB |
| Revised Confidentiality Letter | Cover Letter(s) | 2005-05-05 | PDF 163.8 KB |
| SAR Evaluation | RF Exposure Info | 2005-05-05 | PDF 2.4 MB |
| Block Diagram Metadata only | Block Diagram | PDF 118.2 KB | |
| Schematics Metadata only | Schematics | PDF 642.8 KB | |
| Operational Description Metadata only | Operational Description | PDF 214.2 KB | |
| Alignment Procedure Metadata only | Parts List/Tune Up Info | PDF 109.1 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 78.9 KB |
Application Information
| Application ID | ItYo0w5AuZujH08E3yQ80w== |
|---|---|
| Final Action Date | 2005-05-05 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0010534170 |
| Model | SP210U2 |
| Frequency Range | 440-470 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | SP210 U2 PTT UHF-H |
| Responsible Party | Hyun-Koo Kang, Manager, hkkang@maxoncic.com |
| Agent | Kathy Kathy Kathy, Rhein Tech Laboratories, FCCINFO@rheintech.com |
| Technical Contact | Desmond Fraser, Rhein Tech Laboratories, FCCINFO@rheintech.com |
| Non-Technical Contact | Kathy Grzovic, Rhein Tech Laboratories, FCCINFO@rheintech.com |
| Test Firm | Rick McMurray, Rhein Tech Laboratories, Inc., FCCINFO@rheintech.com |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the three antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 3.74 W/kg; Body-worn: 2.0 W/kg accounting for a 50% duty cycle. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| ItYo0w5AuZujH08E3yQ80w== | 2005-05-05 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application ItYo0w5AuZujH08E3yQ80w==
This application does not exist.
EAS Grant - Application ItYo0w5AuZujH08E3yQ80w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Maxon CIC Corp. Chongho Building, #7-61, Yangjae-Dong Seocho-Ku Seoul, 137-130 South Korea |
Date of Grant: 05/05/2005 Application Dated: 12/28/2004 |
| Attention: Hyun-Koo Kang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RXUSP210U2 |
| Name of Grantee: | Maxon CIC Corp. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | SP210 U2 PTT UHF-H |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 440.0 - 470.0 | 6.2 | 1.5 PM | 16K0F3E | |
| 90 | 440.0 - 470.0 | 6.2 | 1.5 PM | 11K0F3E |
| Output is at the antenna terminal of the device and must not exceed that tested for SAR compliance. This transmitter may operate with the three antennas tested for this filing in Push-to-Talk and body-worn configurations. Body-worn SAR compliance is limited to the specific belt-clip and speaker/microphone configurations tested for this filing. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 3.74 W/kg; Body-worn: 2.0 W/kg accounting for a 50% duty cycle. |