FCC ID RZ5-MD102N-AX211
Intel Wireless 6E AX211
by ONYX Healthcare lnc.
Grantee Code: RZ5 Product Code: MD102NAX211
Latest application date: 2025-06-27
FCC ID Device Details
| FCC ID | RZ5-MD102N-AX211 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | RZ5 |
| Product Code | MD102NAX211 |
| Applicant Business | ONYX Healthcare lnc. 🇹🇼 |
| Related Domains | |
| Equipment Class | Intel Wireless 6E AX211 |
| Test Firm | DEKRA TESTING AND CERTIFICATION CO., LTD. LinKou |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2025-06-27 |
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2025-06-27 |
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2025-06-27 |
| 6025-6985 MHz | Class II permissive change or modification of presently authorized equipment | 2025-06-27 |
| 5180-5240 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD9AX211D2 Grant Date: 08/04/2023 | 2025-06-18 |
| 2402-2480 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD9AX211D2 Grant Date: 07/02/2021 | 2025-06-18 |
| 5955-7115 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD9AX211D2 Grant Date: 06/07/2024 | 2025-06-18 |
| 2422-2462 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD9AX211D2 Grant Date: 07/02/2021 | 2025-06-18 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2025-12-25 | PDF 1.1 MB |
| Internal Photos | Internal Photos | 2025-12-25 | PDF 3.6 MB |
| External Photos | External Photos | 2025-12-25 | PDF 1.6 MB |
| External Photos | External Photos | 2025-12-11 | PDF 51.9 KB |
| ID Label | ID Label/Location Info | 2025-06-27 | PDF 63.6 KB |
| Label Location | ID Label/Location Info | 2025-06-27 | PDF 55 KB |
| ID Label/Location Info | ID Label/Location Info | 2025-06-18 | PDF 88.7 KB |
| Test Setup Photos | Test Setup Photos | 2025-12-25 | PDF 686.9 KB |
| Antenna Spec._Aux | Test Report | 2025-06-27 | PDF 3.2 MB |
| Antenna Spec._Main | Test Report | 2025-06-27 | PDF 3.2 MB |
| SAR Test Report | RF Exposure Info | 2025-06-27 | PDF 1.4 MB |
| Attestation Statement_Part 2.911_d__5__i | Attestation Statements | 2025-06-27 | PDF 255.7 KB |
| Attestation Statement_Part 2.911_d__5__ii | Attestation Statements | 2025-06-27 | PDF 169.7 KB |
| US Agent Letter | Attestation Statements | 2025-06-27 | PDF 309.8 KB |
| US Agent letter | Attestation Statements | 2025-06-18 | PDF 309.8 KB |
| Confidentiality | Cover Letter(s) | 2025-06-27 | PDF 381.4 KB |
| Declaration of Authorization | Cover Letter(s) | 2025-06-27 | PDF 168.7 KB |
| Permissive Change Request Letter | Cover Letter(s) | 2025-06-27 | PDF 438.3 KB |
| Change in ID Authorized letter | Cover Letter(s) | 2025-06-18 | PDF 143.2 KB |
| Change in ID declaration letter | Cover Letter(s) | 2025-06-18 | PDF 338 KB |
| Declaration of authorization | Cover Letter(s) | 2025-06-18 | PDF 168.7 KB |
| confidentiality | Cover Letter(s) | 2025-06-18 | PDF 275.8 KB |
| Appendix A_System Check Data | RF Exposure Info | 2025-06-27 | PDF 602.8 KB |
| Appendix B_Highest Measurement Data | RF Exposure Info | 2025-06-27 | PDF 821 KB |
| Appendix D_Probe Calibration | RF Exposure Info | 2025-06-27 | PDF 4.4 MB |
| Appendix E_Dipole _ Source Calibration_Part1 | RF Exposure Info | 2025-06-27 | PDF 3.8 MB |
| Appendix E_Dipole _ Source Calibration_Part2 | RF Exposure Info | 2025-06-27 | PDF 2.3 MB |
| Block Diagram Metadata only | Block Diagram | PDF 343 KB | |
| Schematics Metadata only | Schematics | PDF 228.7 KB | |
| NII Software Security Info Metadata only | Operational Description | PDF 1.1 MB | |
| Operational Description Metadata only | Operational Description | PDF 83.2 KB |
Application Information
| Application ID | PfG+5274Owtuzf0M3M5csw== |
|---|---|
| Final Action Date | 2025-06-27 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0035827807 |
| Model | MD102N-AX211 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Intel Wireless 6E AX211 |
| Responsible Party | Andrew Wang, Manager, andrewwang@onyx-healthcare.com |
| Agent | Stanley Stanley Stanley, DEKRA Testing and Certification Co., Ltd., stanley.wu@dekra.com |
| Technical Contact | Ashley Chen, DEKRA Testing and Certification Co., Ltd., ashley.chen@dekra.com |
| Non-Technical Contact | Ashley Chen, DEKRA Testing and Certification Co., Ltd., ashley.chen@dekra.com |
| Test Firm | Mirenda Liao, DEKRA TESTING AND CERTIFICATION CO., LTD. LinKou, mirenda.liao@dekra.com |
| TCB Email | dl_radio-certification@kiwa.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 12/25/2025 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Single Modular Approval |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive Change. This change is : 1. Integrating the certified module into a new platform ((Product: Tablet PC, Brand: onyx, Model: ONYX-MD102N) The highest reported SAR for body-worn and simultaneous transmission exposure conditions are 1.15 W/kg and 0.96 W/kg, respectively. Power Output listed is conducted. Modular Approval. Power output has been reduced at the upper bandedge channels as shown in filings under this FCC ID. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. This filing meets MPE requirements of KDB 447498 and can be used in mobile configurations. Addition of new antenna, antenna type is different from the original application. Antenna type - Wieson Dipole ARY121-0009-002-H0, tested at 20cm. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| PfG+5274Owtuzf0M3M5csw== | 2025-06-27 | Class II permissive change or modification of presently authorized equipment |
| JWmFBozAsKyy8VoL3kjPuA== | 2025-06-27 | Class II permissive change or modification of presently authorized equipment |
| Bxxyc08+jj4kq4reGOhfnA== | 2025-06-27 | Class II permissive change or modification of presently authorized equipment |
| 1FQ8Qvr1BWAjNzbPoB4hIg== | 2025-06-27 | Class II permissive change or modification of presently authorized equipment |
| j0Kj0OZeEg4x6Q4iq+E/FA== | 2025-06-18 | Change in identification of presently authorized equipment. Original FCC ID: PD9AX211D2 Grant Date: 08/04/2023 |
| hfhjOz6USXClUkACit0Fxw== | 2025-06-18 | Change in identification of presently authorized equipment. Original FCC ID: PD9AX211D2 Grant Date: 07/02/2021 |
| QYw7UEM6fQIJ2vQXApRVCg== | 2025-06-18 | Change in identification of presently authorized equipment. Original FCC ID: PD9AX211D2 Grant Date: 06/07/2024 |
| 3J/aeyavXi3eTc2XjckIlw== | 2025-06-18 | Change in identification of presently authorized equipment. Original FCC ID: PD9AX211D2 Grant Date: 06/07/2024 |
| 1cgUUtEvAGOSdIvMxvzalw== | 2025-06-18 | Change in identification of presently authorized equipment. Original FCC ID: PD9AX211D2 Grant Date: 07/02/2021 |
Equipment Authorization
| Frequency | Output | Grant Notes |
|---|---|---|
| CC | ||
| 2402-2480 MHz | 0.0110000 | CC |
| 2402-2480 MHz | 0.009 | CC |
| 2412-2472 MHz | 0.979 | CC, MO |
| 2422-2462 MHz | 0.802 | CC, MO |
| 5190-5230 MHz | 0.249 | CC, MO |
| 5210 MHz | 0.082 | CC, MO |
| 5250 MHz | 0.067 | CC, MO |
| 5260-5320 MHz | 0.152 | CC, MO, ND |
| 5270-5310 MHz | 0.246 | CC, MO, ND |
| 5290 MHz | 0.081 | CC, MO, ND |
| 5500-5700 MHz | 0.249 | CC, MO, ND |
| 5530-5690 MHz | 0.246 | CC, MO, ND |
| 5710 MHz | 0.128 | CC, MO, ND |
| 5720 MHz | 0.114 | CC, MO, ND |
| 5745-5825 MHz | 0.259 | CC, MO |
| 5755-5795 MHz | 0.268 | CC, MO |
| 5775 MHz | 0.229 | CC, MO |
| 5815 MHz | 0.306 | CC, MO |
| 5835-5875 MHz | 0.706 | CC, MO |
| 5845-5885 MHz | 0.318 | CC, MO |
| 5855 MHz | 0.6 | CC, MO |
| 5955-7115 MHz | 0.003 | CC, EP, MO |
| 5965-7085 MHz | 0.006 | CC, EP, MO |
| 5985-7025 MHz | 0.011 | CC, EP, MO |
| 6025-6985 MHz | 0.021 | CC, EP, MO |
Grants
TCB Grant - Application QYw7UEM6fQIJ2vQXApRVCg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 06/18/2025 Application Dated: 06/18/2025 |
| ONYX Healthcare lnc. |
| 4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MD102N-AX211 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | Intel Wireless 6E AX211 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application PfG+5274Owtuzf0M3M5csw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 06/27/2025 Application Dated: 06/27/2025 |
| ONYX Healthcare lnc. |
| 4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MD102N-AX211 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Intel Wireless 6E AX211 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.009 | ||
| CC MO | 15C | 2412.0 - 2472.0 | 0.979 | ||
| CC MO | 15C | 2422.0 - 2462.0 | 0.802 |
| Class II Permissive Change. This change is : 1. Integrating the certified module into a new platform ((Product: Tablet PC, Brand: onyx, Model: ONYX-MD102N) The highest reported SAR for body-worn and simultaneous transmission exposure conditions are 1.15 W/kg and 0.96 W/kg, respectively. Power Output listed is conducted. Modular Approval. Power output has been reduced at the upper bandedge channels as shown in filings under this FCC ID. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. This filing meets MPE requirements of KDB 447498 and can be used in mobile configurations. Addition of new antenna, antenna type is different from the original application. Antenna type - Wieson Dipole ARY121-0009-002-H0, tested at 20cm. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
TCB Grant - Application JWmFBozAsKyy8VoL3kjPuA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 06/27/2025 Application Dated: 06/27/2025 |
| ONYX Healthcare lnc. |
| 4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MD102N-AX211 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Intel Wireless 6E AX211 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.011 |
| Class II Permissive Change. This change is : 1. Integrating the certified module into a new platform ((Product: Tablet PC, Brand: onyx, Model: ONYX-MD102N) The highest reported SAR for body-worn and simultaneous transmission exposure conditions are 0.18 W/kg and 1.35 W/kg, respectively. Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This filing meets MPE requirements of KDB447498 and can be used in mobile configurations. Addition of new antenna, antenna type is different from the original application. Antenna type - Wieson Dipole ARY121-0009-002-H0, tested at 20cm. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application j0Kj0OZeEg4x6Q4iq+E/FA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 06/18/2025 Application Dated: 06/18/2025 |
| ONYX Healthcare lnc. |
| 4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MD102N-AX211 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Intel Wireless 6E AX211 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.163 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.249 | ||
| CC MO | 15E | 5210.0 - 5210.0 | 0.082 | ||
| CC MO | 15E | 5250.0 - 5250.0 | 0.067 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.152 | ||
| CC MO ND | 15E | 5270.0 - 5310.0 | 0.246 | ||
| CC MO ND | 15E | 5290.0 - 5290.0 | 0.081 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.249 | ||
| CC MO ND | 15E | 5710.0 - 5710.0 | 0.128 | ||
| CC MO ND | 15E | 5720.0 - 5720.0 | 0.114 | ||
| CC MO ND | 15E | 5530.0 - 5690.0 | 0.246 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.259 | ||
| CC MO | 15E | 5755.0 - 5795.0 | 0.268 | ||
| CC MO | 15E | 5775.0 - 5775.0 | 0.229 | ||
| CC MO | 15E | 5845.0 - 5885.0 | 0.318 | ||
| CC MO | 15E | 5835.0 - 5875.0 | 0.706 | ||
| CC MO | 15E | 5855.0 - 5855.0 | 0.6 | ||
| CC MO | 15E | 5815.0 - 5815.0 | 0.306 |
| Modular Approval. Power Output listed is conducted for UNII-1 to UNII-3 and EIRP for UNII-4 bands. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter has 20MHz, 40MHz, 80MHz and 160MHz bandwidth modes as described in this filing. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. This filing meets MPE requirements of KDB 447498 and can be used in mobile configurations. Addition of a new antenna and antenna type for the UNII-4 Band. (Antenna type: Dipole Antenna Wieson Part no ARY121-0009-002-H0). |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
TCB Grant - Application hfhjOz6USXClUkACit0Fxw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 06/18/2025 Application Dated: 06/18/2025 |
| ONYX Healthcare lnc. |
| 4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MD102N-AX211 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Intel Wireless 6E AX211 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.011 |
| Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This filing meets MPE requirements of KDB 447498 and can be used in mobile configurations. Addition of new antenna, antenna type is different from the original application. Antenna type - Wieson Dipole ARY121-0009-002-H0, tested at 20cm. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application Bxxyc08+jj4kq4reGOhfnA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 06/27/2025 Application Dated: 06/27/2025 |
| ONYX Healthcare lnc. |
| 4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MD102N-AX211 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Intel Wireless 6E AX211 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.163 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.249 | ||
| CC MO | 15E | 5210.0 - 5210.0 | 0.082 | ||
| CC MO | 15E | 5250.0 - 5250.0 | 0.067 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.152 | ||
| CC MO ND | 15E | 5270.0 - 5310.0 | 0.246 | ||
| CC MO ND | 15E | 5290.0 - 5290.0 | 0.081 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.249 | ||
| CC MO ND | 15E | 5710.0 - 5710.0 | 0.128 | ||
| CC MO ND | 15E | 5720.0 - 5720.0 | 0.114 | ||
| CC MO ND | 15E | 5530.0 - 5690.0 | 0.246 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.259 | ||
| CC MO | 15E | 5755.0 - 5795.0 | 0.268 | ||
| CC MO | 15E | 5775.0 - 5775.0 | 0.229 | ||
| CC MO | 15E | 5845.0 - 5885.0 | 0.318 | ||
| CC MO | 15E | 5835.0 - 5875.0 | 0.706 | ||
| CC MO | 15E | 5855.0 - 5855.0 | 0.6 | ||
| CC MO | 15E | 5815.0 - 5815.0 | 0.306 |
| Class II Permissive Change. This change is : 1. Integrating the certified module into a new platform ((Product: Tablet PC, Brand: onyx, Model: ONYX-MD102N) The highest reported SAR for body-worn and simultaneous transmission exposure conditions are 1.17 W/kg and 1.34 W/kg, respectively. Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter has 20MHz, 40MHz, 80MHz bandwidth modes as described in this filing. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.63W/kg and 1.24W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. Addition of new antenna, antenna type is different from the original application. Antenna type - Wieson Dipole ARY121-0009-002-H0, tested at 20cm.Modular Approval. Power Output listed is conducted for UNII-1 to UNII-3 and EIRP for UNII-4 bands. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter has 20MHz, 40MHz, 80MHz and 160MHz bandwidth modes as described in this filing. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. This filing meets MPE requirements of KDB 447498 and can be used in mobile configurations. Addition of a new antenna and antenna type for the UNII-4 Band. (Antenna type: Dipole Antenna Wieson Part no ARY121-0009-002-H0). |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
TCB Grant - Application 3J/aeyavXi3eTc2XjckIlw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 06/18/2025 Application Dated: 06/18/2025 |
| ONYX Healthcare lnc. |
| 4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MD102N-AX211 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | 15E 6 GHz Low Power Indoor Client |
| Notes: | Intel Wireless 6E AX211 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC EP MO | 15E | 5955.0 - 7115.0 | 0.003 | ||
| CC EP MO | 15E | 5965.0 - 7085.0 | 0.006 | ||
| CC EP MO | 15E | 5985.0 - 7025.0 | 0.011 | ||
| CC EP MO | 15E | 6025.0 - 6985.0 | 0.021 |
| Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This filing meets MPE requirements of KDB447498 and can be used in mobile configurations. Addition of a new antenna, antenna type is different with the original application. Wieson P/N ARY121-0009-002-H0, (Antenna type: Dipole Antenna / 6XD Grant). Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device supports 20, 40, 80 and 160 MHz BW modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
TCB Grant - Application 1FQ8Qvr1BWAjNzbPoB4hIg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 06/27/2025 Application Dated: 06/27/2025 |
| ONYX Healthcare lnc. |
| 4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MD102N-AX211 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | 15E 6 GHz Low Power Indoor Client |
| Notes: | Intel Wireless 6E AX211 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC EP MO | 15E | 5955.0 - 7115.0 | 0.003 | ||
| CC EP MO | 15E | 5965.0 - 7085.0 | 0.006 | ||
| CC EP MO | 15E | 5985.0 - 7025.0 | 0.011 | ||
| CC EP MO | 15E | 6025.0 - 6985.0 | 0.021 |
| Class II Permissive Change. This change is : 1. Integrating the certified module into a new platform ((Product: Tablet PC, Brand: onyx, Model: ONYX-MD102N) The highest reported SAR for body-worn, simultaneous and power density transmission exposure conditions are 1.17 W/kg, 1.35 W/kg and 6.03 W/m2, respectively. Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This filing meets MPE requirements of KDB447498 and can be used in mobile configurations. Addition of a new antenna, antenna type is different with the original application. Wieson P/N ARY121-0009-002-H0, (Antenna type: Dipole Antenna / 6XD Grant). Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device supports 20, 40, 80 and 160 MHz BW modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
TCB Grant - Application 1cgUUtEvAGOSdIvMxvzalw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 06/18/2025 Application Dated: 06/18/2025 |
| ONYX Healthcare lnc. |
| 4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MD102N-AX211 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Intel Wireless 6E AX211 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.009 | ||
| CC MO | 15C | 2412.0 - 2472.0 | 0.979 | ||
| CC MO | 15C | 2422.0 - 2462.0 | 0.802 |
| Power Output listed is conducted. Modular Approval. Power output has been reduced at the upper bandedge channels as shown in filings under this FCC ID. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. This filing meets MPE requirements of KDB 447498 and can be used in mobile configurations. Addition of new antenna, antenna type is different from the original application. Antenna type - Wieson Dipole ARY121-0009-002-H0, tested at 20cm. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |