FCC ID RZ5-MEDPC-2100
Intel Dual Band Wireless-AC 9260
by ONYX Healthcare lnc.
Grantee Code: RZ5 Product Code: MEDPC2100
Latest application date: 2024-10-21
FCC ID Device Details
| FCC ID | RZ5-MEDPC-2100 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | RZ5 |
| Product Code | MEDPC2100 |
| Applicant Business | ONYX Healthcare lnc. 🇹🇼 |
| Related Domains | |
| Equipment Class | Intel Dual Band Wireless-AC 9260 |
| Test Firm | DEKRA TESTING AND CERTIFICATION CO., LTD. LinKou |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2024-10-21 |
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2024-10-21 |
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2024-10-21 |
| 2402-2480 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD99260NG Grant Date: 07/24/2017 | 2024-08-27 |
| 2422-2462 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD99260NG Grant Date: 07/24/2017 | 2024-08-27 |
| 5180-5240 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD99260NG Grant Date: 07/24/2017 | 2024-08-27 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2025-02-23 | PDF 5.1 MB |
| User Manual | Users Manual | 2024-10-21 | PDF 316.4 KB |
| Internal Photos | Internal Photos | 2024-10-21 | PDF 618.2 KB |
| External Photos | External Photos | 2025-02-23 | PDF 110.7 KB |
| External Photos | External Photos | 2024-10-21 | PDF 1.4 MB |
| Label Sample and Location | ID Label/Location Info | 2024-08-27 | PDF 74.4 KB |
| TSUP | Test Setup Photos | 2024-10-21 | PDF 842.7 KB |
| Antenna Specifications | Test Report | 2024-10-21 | PDF 1.5 MB |
| Test Report | Test Report | 2024-10-21 | PDF 1.8 MB |
| Test Report Appendices BT BR EDR | Test Report | 2024-10-21 | PDF 393.6 KB |
| Test Report Appendices BT LE | Test Report | 2024-10-21 | PDF 299.8 KB |
| Test Report Appendices WIFI 2.4G | Test Report | 2024-10-21 | PDF 3.6 MB |
| Test Report Appendices pt. 1 | Test Report | 2024-10-21 | PDF 4.5 MB |
| Test Report Appendices pt. 2 | Test Report | 2024-10-21 | PDF 4.1 MB |
| Test Report BT BR EDR | Test Report | 2024-10-21 | PDF 825.3 KB |
| Test Report BT LE | Test Report | 2024-10-21 | PDF 718.4 KB |
| Test Report wifi 2.4G | Test Report | 2024-10-21 | PDF 1.6 MB |
| Attestation Statement 2.911(d)(7) | Attestation Statements | 2024-10-21 | PDF 198.3 KB |
| Attestation Statement Part 2.911(d)(7) | Attestation Statements | 2024-10-21 | PDF 198.3 KB |
| Attstn Stmts Part 2.911(d)(5)(i) | Attestation Statements | 2024-10-21 | PDF 665.7 KB |
| Attstn Stmts Part 2.911(d)(5)(ii) | Attestation Statements | 2024-10-21 | PDF 665.5 KB |
| Attstn Stmts part 2.911(d)(5)(ii) | Attestation Statements | 2024-10-21 | PDF 665.5 KB |
| Attsttn Sttmnts 2.911(d)(5)(i) | Attestation Statements | 2024-10-21 | PDF 665.7 KB |
| Attestation Statements 2.911(d)(7) | Attestation Statements | 2024-08-27 | PDF 198.3 KB |
| Attstn Stmt Part 2.911(d)(5)(i) | Attestation Statements | 2024-08-27 | PDF 665.7 KB |
| Attstn Stmt part 2.911(d)(5)(i) | Attestation Statements | 2024-08-27 | PDF 665.7 KB |
| Attstn Stmt part 2.911(d)(5)(ii) | Attestation Statements | 2024-08-27 | PDF 665.5 KB |
| Authorization Letter | Cover Letter(s) | 2024-10-21 | PDF 504.3 KB |
| C2PC Letter | Cover Letter(s) | 2024-10-21 | PDF 161.7 KB |
| Change in ID (New Applicant) | Cover Letter(s) | 2024-08-27 | PDF 519.3 KB |
| Change in ID (Original Applicant) | Cover Letter(s) | 2024-08-27 | PDF 103.3 KB |
| Confidentiality Letter | Cover Letter(s) | 2024-08-27 | PDF 590.7 KB |
| RF Exposure MPE | RF Exposure Info | 2024-10-21 | PDF 199.1 KB |
Application Information
| Application ID | xrRcCWQ1b0o6xOqmvDjbag== |
|---|---|
| Final Action Date | 2024-10-21 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0035827807 |
| Model | MEDPC-2100 |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Intel Dual Band Wireless-AC 9260 |
| Responsible Party | Andrew Wang, Manager, andrewwang@onyx-healthcare.com |
| Test Firm | Mirenda Liao, DEKRA TESTING AND CERTIFICATION CO., LTD. LinKou, mirenda.liao@dekra.com |
| TCB Email | tei@timcoengr.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Single Modular Approval |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. This transmitter has 20MHz, 40MHz and 80MHz bandwidth modes as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.73W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14 mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. Class II Permissive Change: Adds a new type of antenna (dipole) to the portfolio. Reduces output power for 2.4 and 5 GHz Wi-Fi modes via software. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| xrRcCWQ1b0o6xOqmvDjbag== | 2024-10-21 | Class II permissive change or modification of presently authorized equipment |
| oQjcvuupYfxA5hFPoBYKOg== | 2024-10-21 | Class II permissive change or modification of presently authorized equipment |
| VoYktCMJujb7y3Rv1qMwxw== | 2024-10-21 | Class II permissive change or modification of presently authorized equipment |
| DfHKcSqD5RCO/aflI1BXdQ== | 2024-10-21 | Class II permissive change or modification of presently authorized equipment |
| k4O76WwOjSNNwDpJylyX5Q== | 2024-08-27 | Change in identification of presently authorized equipment. Original FCC ID: PD99260NG Grant Date: 07/24/2017 |
| YVRsKLfvuz+/H4TEnQfJSg== | 2024-08-27 | Change in identification of presently authorized equipment. Original FCC ID: PD99260NG Grant Date: 07/24/2017 |
| G8o6ffE0IxfYVEzyFDgQeQ== | 2024-08-27 | Change in identification of presently authorized equipment. Original FCC ID: PD99260NG Grant Date: 07/24/2017 |
| DHuYv8aL7T+hwVQS8glzfw== | 2024-08-27 | Change in identification of presently authorized equipment. Original FCC ID: PD99260NG Grant Date: 07/24/2017 |
Equipment Authorization
| Frequency | Output | Rules | Grant Notes |
|---|---|---|---|
| 2402-2480 MHz | 0.0140000 | 15C | CC |
| 2402-2480 MHz | 0.01 | 15C | CC |
| 2402-2480 MHz | 0.0130000 | 15C | CC |
| 2402-2480 MHz | 0.009 | 15C | CC |
| 2412-2472 MHz | 0.984 | 15C | CC, MO |
| 2412-2472 MHz | 0.914 | 15C | CC, MO |
| 2422-2462 MHz | 0.43 | 15C | CC, MO |
| 5180-5240 MHz | 0.182 | 15E | CC, MO |
| 5190-5230 MHz | 0.134 | 15E | CC, MO |
| 5210 MHz | 0.062 | 15E | CC, MO |
| 5260-5320 MHz | 0.21 | 15E | CC, MO, ND |
| 5260-5320 MHz | 0.229 | 15E | CC, MO, ND |
| 5270-5310 MHz | 0.11 | 15E | CC, MO, ND |
| 5290 MHz | 0.052 | 15E | CC, MO, ND |
| 5500-5720 MHz | 0.216 | 15E | CC, MO, ND |
| 5500-5700 MHz | 0.198 | 15E | CC, MO, ND |
| 5510-5670 MHz | 0.221 | 15E | CC, MO, ND |
| 5530-5690 MHz | 0.232 | 15E | CC, MO, ND |
| 5745-5825 MHz | 0.299 | 15E | CC, MO |
| 5745-5825 MHz | 0.296 | 15E | CC, MO |
| 5755-5795 MHz | 0.198 | 15E | CC, MO |
| 5775 MHz | 0.148 | 15E | CC, MO |
Grants
TCB Grant - Application YVRsKLfvuz+/H4TEnQfJSg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 08/27/2024 Application Dated: 08/23/2024 |
| ONYX Healthcare lnc. |
| 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15B | - |
EAS Grant - Application YVRsKLfvuz+/H4TEnQfJSg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., New Taipei City, 231028 Taiwan |
Date of Grant: 08/27/2024 Application Dated: 08/23/2024 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15B | - |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 10/21/2024 Application Dated: 10/17/2024 |
| ONYX Healthcare lnc. |
| 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.182 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.21 | ||
| CC MO ND | 15E | 5500.0 - 5720.0 | 0.216 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.296 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. This transmitter has 20MHz, 40MHz and 80MHz bandwidth modes as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.73W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14 mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. Class II Permissive Change: Adds a new type of antenna (dipole) to the portfolio. Reduces output power for 2.4 and 5 GHz Wi-Fi modes via software. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application xrRcCWQ1b0o6xOqmvDjbag==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., New Taipei City, 231028 Taiwan |
Date of Grant: 10/21/2024 Application Dated: 10/17/2024 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.182 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.21 | ||
| CC MO ND | 15E | 5500.0 - 5720.0 | 0.216 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.296 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. This transmitter has 20MHz, 40MHz and 80MHz bandwidth modes as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.73W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14 mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. Class II Permissive Change: Adds a new type of antenna (dipole) to the portfolio. Reduces output power for 2.4 and 5 GHz Wi-Fi modes via software. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 10/21/2024 Application Dated: 10/17/2024 |
| ONYX Healthcare lnc. |
| 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.013 |
| Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported Body and Simultaneous SAR values are 0.03W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. Class II Permissive Change: Adds a new type of antenna (dipole) to the portfolio. Reduces output power for 2.4 and 5 GHz Wi-Fi modes via software. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application VoYktCMJujb7y3Rv1qMwxw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., New Taipei City, 231028 Taiwan |
Date of Grant: 10/21/2024 Application Dated: 10/17/2024 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.013 |
| Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported Body and Simultaneous SAR values are 0.03W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. Class II Permissive Change: Adds a new type of antenna (dipole) to the portfolio. Reduces output power for 2.4 and 5 GHz Wi-Fi modes via software. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 10/21/2024 Application Dated: 10/17/2024 |
| ONYX Healthcare lnc. |
| 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15B | - |
| Class II Permissive Change: Adds a new type of antenna (dipole) to the portfolio. Reduces output power for 2.4 and 5 GHz Wi-Fi modes via software. |
EAS Grant - Application oQjcvuupYfxA5hFPoBYKOg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., New Taipei City, 231028 Taiwan |
Date of Grant: 10/21/2024 Application Dated: 10/17/2024 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15B | - |
| Class II Permissive Change: Adds a new type of antenna (dipole) to the portfolio. Reduces output power for 2.4 and 5 GHz Wi-Fi modes via software. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 08/27/2024 Application Dated: 08/23/2024 |
| ONYX Healthcare lnc. |
| 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.014 |
| Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported Body and Simultaneous SAR values are 0.03W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application k4O76WwOjSNNwDpJylyX5Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., New Taipei City, 231028 Taiwan |
Date of Grant: 08/27/2024 Application Dated: 08/23/2024 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.014 |
| Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported Body and Simultaneous SAR values are 0.03W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 08/27/2024 Application Dated: 08/23/2024 |
| ONYX Healthcare lnc. |
| 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.01 | ||
| CC MO | 15C | 2412.0 - 2472.0 | 0.984 | ||
| CC MO | 15C | 2422.0 - 2462.0 | 0.43 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.40W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application G8o6ffE0IxfYVEzyFDgQeQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., New Taipei City, 231028 Taiwan |
Date of Grant: 08/27/2024 Application Dated: 08/23/2024 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.01 | ||
| CC MO | 15C | 2412.0 - 2472.0 | 0.984 | ||
| CC MO | 15C | 2422.0 - 2462.0 | 0.43 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.40W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 08/27/2024 Application Dated: 08/23/2024 |
| ONYX Healthcare lnc. |
| 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.191 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.134 | ||
| CC MO | 15E | 5210.0 - 5210.0 | 0.062 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.229 | ||
| CC MO ND | 15E | 5270.0 - 5310.0 | 0.11 | ||
| CC MO ND | 15E | 5290.0 - 5290.0 | 0.052 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.198 | ||
| CC MO ND | 15E | 5510.0 - 5670.0 | 0.221 | ||
| CC MO ND | 15E | 5530.0 - 5690.0 | 0.232 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.299 | ||
| CC MO | 15E | 5755.0 - 5795.0 | 0.198 | ||
| CC MO | 15E | 5775.0 - 5775.0 | 0.148 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. This transmitter has 20MHz, 40MHz and 80MHz bandwidth modes as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.73W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application DHuYv8aL7T+hwVQS8glzfw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., New Taipei City, 231028 Taiwan |
Date of Grant: 08/27/2024 Application Dated: 08/23/2024 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.191 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.134 | ||
| CC MO | 15E | 5210.0 - 5210.0 | 0.062 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.229 | ||
| CC MO ND | 15E | 5270.0 - 5310.0 | 0.11 | ||
| CC MO ND | 15E | 5290.0 - 5290.0 | 0.052 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.198 | ||
| CC MO ND | 15E | 5510.0 - 5670.0 | 0.221 | ||
| CC MO ND | 15E | 5530.0 - 5690.0 | 0.232 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.299 | ||
| CC MO | 15E | 5755.0 - 5795.0 | 0.198 | ||
| CC MO | 15E | 5775.0 - 5775.0 | 0.148 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. This transmitter has 20MHz, 40MHz and 80MHz bandwidth modes as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.73W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 10/21/2024 Application Dated: 10/17/2024 |
| ONYX Healthcare lnc. |
| 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., |
| New Taipei City, 231028 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.009 | ||
| CC MO | 15C | 2412.0 - 2472.0 | 0.914 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.40W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14 mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. Class II Permissive Change: Adds a new type of antenna (dipole) to the portfolio. Reduces output power for 2.4 and 5 GHz Wi-Fi modes via software. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application DfHKcSqD5RCO/aflI1BXdQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 4F,No.135,Lane235,Baoqiao Rd., Xindian Dist., New Taipei City, 231028 Taiwan |
Date of Grant: 10/21/2024 Application Dated: 10/17/2024 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-2100 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Intel Dual Band Wireless-AC 9260 |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.009 | ||
| CC MO | 15C | 2412.0 - 2472.0 | 0.914 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.40W/kg and 1.41W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 14 mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. Class II Permissive Change: Adds a new type of antenna (dipole) to the portfolio. Reduces output power for 2.4 and 5 GHz Wi-Fi modes via software. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |