FCC ID RZ5-MEDPC-6200-A
Fanless Medical Grade Box PC
by ONYX Healthcare lnc.
Grantee Code: RZ5 Product Code: MEDPC6200A
Latest application date: 2017-12-13
FCC ID Device Details
| FCC ID | RZ5-MEDPC-6200-A |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | RZ5 |
| Product Code | MEDPC6200A |
| Applicant Business | ONYX Healthcare lnc. 🇹🇼 |
| Related Domains | |
| Equipment Class | Fanless Medical Grade Box PC |
| Test Firm | DEKRA TESTING AND CERTIFICATION CO., LTD. LinKou |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2017-12-13 |
| 2402-2480 MHz | Original Equipment | 2017-12-13 |
| 2402-2480 MHz | Original Equipment | 2017-12-13 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2017-12-13 | PDF 623.5 KB |
| Internal Photos | Internal Photos | 2017-12-13 | PDF 5.1 MB |
| External Photos | External Photos | 2017-12-13 | PDF 521.9 KB |
| Label and Label Location | ID Label/Location Info | 2017-12-13 | PDF 83.4 KB |
| Test Setup Photos | Test Setup Photos | 2017-12-13 | PDF 663.9 KB |
| Test setup Photos | Test Setup Photos | 2017-12-13 | PDF 663.9 KB |
| TEst report | Test Report | 2017-12-13 | PDF 2.3 MB |
| Test Report | Test Report | 2017-12-13 | PDF 2.8 MB |
| Test report | Test Report | 2017-12-13 | PDF 2.1 MB |
| Cover Letters | Cover Letter(s) | 2017-12-13 | PDF 236.7 KB |
| RF Exposure info | RF Exposure Info | 2017-12-13 | PDF 110.5 KB |
| Block Diagram Metadata only | Block Diagram | PDF 1.4 MB | |
| Schematics Metadata only | Schematics | PDF 1.4 MB | |
| Operational Description Metadata only | Operational Description | PDF 369.6 KB |
Application Information
| Application ID | WvSdd0sj2NBh37WCPsgDOQ== |
|---|---|
| Final Action Date | 2017-12-13 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0022396329 |
| Model | MEDPC-6200-A |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Fanless Medical Grade Box PC |
| Responsible Party | Andrew Wang, Manager, andrewwang@onyx-healthcare.com |
| Test Firm | Mirenda Liao, DEKRA TESTING AND CERTIFICATION CO., LTD. LinKou, mirenda.liao@dekra.com |
| TCB Email | Stuart.Beck@nemko.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is combined conducted. This device has 20 MHz and 40MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 06-96 as a Client only without Radar Detection. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| WvSdd0sj2NBh37WCPsgDOQ== | 2017-12-13 | Original Equipment |
| Ibu2udqz+Sc9c1Qh2R/rnw== | 2017-12-13 | Original Equipment |
| 020/0JWgEpcqXrkrWWo1cQ== | 2017-12-13 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application WvSdd0sj2NBh37WCPsgDOQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 12/13/2017 Application Dated: 12/11/2017 |
| ONYX Healthcare lnc. |
| 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., |
| New Taipei City, 231 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-6200-A |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Fanless Medical Grade Box PC |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15E | 5180.0 - 5240.0 | 0.1047 | |||
| ND | 15E | 5260.0 - 5320.0 | 0.0927 | ||
| ND | 15E | 5500.0 - 5700.0 | 0.0495 | ||
| 15E | 5745.0 - 5825.0 | 0.0497 |
| Power listed is combined conducted. This device has 20 MHz and 40MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 06-96 as a Client only without Radar Detection. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application WvSdd0sj2NBh37WCPsgDOQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., New Taipei City, 231 Taiwan |
Date of Grant: 12/13/2017 Application Dated: 12/11/2017 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-6200-A |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Fanless Medical Grade Box PC |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15E | 5180.0 - 5240.0 | 0.1047 | |||
| ND | 15E | 5260.0 - 5320.0 | 0.0927 | ||
| ND | 15E | 5500.0 - 5700.0 | 0.0495 | ||
| 15E | 5745.0 - 5825.0 | 0.0497 |
| Power listed is combined conducted. This device has 20 MHz and 40MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 06-96 as a Client only without Radar Detection. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 12/13/2017 Application Dated: 12/08/2017 |
| ONYX Healthcare lnc. |
| 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., |
| New Taipei City, 231 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-6200-A |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Fanless Medical Grade Box PC |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0047 | |||
| 15C | 2412.0 - 2462.0 | 0.2275 | |||
| 15C | 2422.0 - 2452.0 | 0.2023 |
| Output power listed is conducted. This device has 20 MHz and 40MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provided separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application Ibu2udqz+Sc9c1Qh2R/rnw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., New Taipei City, 231 Taiwan |
Date of Grant: 12/13/2017 Application Dated: 12/08/2017 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-6200-A |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Fanless Medical Grade Box PC |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0047 | |||
| 15C | 2412.0 - 2462.0 | 0.2275 | |||
| 15C | 2422.0 - 2452.0 | 0.2023 |
| Output power listed is conducted. This device has 20 MHz and 40MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provided separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 12/13/2017 Application Dated: 12/08/2017 |
| ONYX Healthcare lnc. |
| 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., |
| New Taipei City, 231 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-6200-A |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Fanless Medical Grade Box PC |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.006 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provided separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance |
EAS Grant - Application 020/0JWgEpcqXrkrWWo1cQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., New Taipei City, 231 Taiwan |
Date of Grant: 12/13/2017 Application Dated: 12/08/2017 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ5-MEDPC-6200-A |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Fanless Medical Grade Box PC |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.006 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provided separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance |
| Mail To: |