FCC ID RZ5-VM300

Intel Wi-Fi 6E AX210

by ONYX Healthcare lnc.

Grantee Code: RZ5   Product Code: VM300
Latest application date: 2025-06-30

FCC ID Device Details

FCC IDRZ5-VM300
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeRZ5
Product CodeVM300
Applicant BusinessONYX Healthcare lnc. 🇹🇼
Related Domains onyx-healthcare.com
Equipment ClassIntel Wi-Fi 6E AX210
Test FirmIntel Corporation S.A.S.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 05/07/20212025-06-30
5955-6415 MHzChange in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 11/21/20232025-06-30
5180-5240 MHzChange in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 09/11/20232025-06-30
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 05/07/20212025-06-30
5955-7115 MHzChange in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 10/06/20212025-06-30

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2025-12-27PDF 98.7 KB
Label SampleID Label/Location Info2025-06-30PDF 86.4 KB
Label Sample and LocationID Label/Location Info2025-06-30PDF 86.4 KB
Att Statements 2.911(d)(5)(7)Attestation Statements2025-06-30PDF 306.2 KB
Att Statements 2.911(d)(5)(i)Attestation Statements2025-06-30PDF 256.5 KB
Att Statements 2.911(d)(5)(ii)Attestation Statements2025-06-30PDF 169.3 KB
Authorization LetterCover Letter(s)2025-06-30PDF 168 KB
Change in ID - New ApplicantCover Letter(s)2025-06-30PDF 338.7 KB
Change in ID Letter - OG App DIPOLECover Letter(s)2025-06-30PDF 171 KB
Change in ID Letter - OG App PIFACover Letter(s)2025-06-30PDF 132.4 KB
Confidentiality LetterCover Letter(s)2025-06-30PDF 711.2 KB
OpDes Software Security Metadata onlySDR Software/Security Info.PDF 1.1 MB

Application Information

Application IDt7cDWmXeV8fB/rvJVPVXMw==
Final Action Date2025-06-30
Application PurposeChange in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 05/07/2021
Applicant FRN0035827807
ModelVM300
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionIntel Wi-Fi 6E AX210
Responsible PartyAndrew Wang, Manager, andrewwang@onyx-healthcare.com , 886-2-8919-2188
Test FirmNawfal ASRIH, Intel Corporation S.A.S., nawfal.asrih@intel.com , 003349300962
TCB Emailtei@timcoengr.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date12/27/2025
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsPower Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported Body and Simultaneous SAR values are 0.02W/kg and 1.57W/kg respectively. This module approved for mobile use with Antenna type: Dipole. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 13mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance.

Applications

Application IDDatePurpose
t7cDWmXeV8fB/rvJVPVXMw==2025-06-30Change in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 05/07/2021
nK3OS7uotKfHKkE1WQWnfg==2025-06-30Change in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 11/21/2023
lmsljdPZmGBfbq9C0YFyow==2025-06-30Change in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 09/11/2023
hn9fsgazAPjhHblVVgJwvA==2025-06-30Change in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 10/19/2020
S2fAHXkkfsjpEDJdcqH1Cw==2025-06-30Change in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 05/07/2021
CwG6bUtxev7GJnk8ZLTsGg==2025-06-30Change in identification of presently authorized equipment. Original FCC ID: PD9AX210NG Grant Date: 10/06/2021

Equipment Authorization

FrequencyOutputGrant Notes
2402-2480 MHz0.01CC
2402-2480 MHz0.0140000CC
2412-2472 MHz0.792CC, MO
2422-2462 MHz0.602CC, MO
5190-5230 MHz0.199CC, MO
5210 MHz0.089CC, MO
5250 MHz0.061CC, MO
5260-5320 MHz0.165CC, MO, ND
5270-5310 MHz0.153CC, MO, ND
5290 MHz0.084CC, MO, ND
5500-5700 MHz0.245CC, MO, ND
5530-5690 MHz0.228CC, MO, ND
5710 MHz0.249CC, MO, ND
5720 MHz0.134CC, MO, ND
5745-5825 MHz0.262CC, MO
5755-5795 MHz0.27CC, MO
5775 MHz0.195CC, MO
5815 MHz0.226CC, MO
5835-5875 MHz0.692CC, MO
5845-5885 MHz0.332CC, MO
5855 MHz0.733CC, MO
5955-7115 MHz0.003CC, EP, MO
5955-7115 MHz0.012CC, EP, MO
5965-7085 MHz0.024CC, EP, MO
5965-6405 MHz0.717CC, EP, MO
5965-7085 MHz0.007CC, EP, MO
5985-7025 MHz0.049CC, EP, MO
5985-6385 MHz0.733CC, EP, MO
5985-7025 MHz0.013CC, EP, MO
6025-6985 MHz0.094CC, EP, MO
6025-6345 MHz0.338CC, EP, MO
6025-6985 MHz0.026CC, EP, MO
6535-6855 MHz0.577CC, EP, MO
6565-6845 MHz0.783CC, EP, MO
6625-6785 MHz0.745CC, EP, MO
6665 MHz0.331CC, EP, MO

Grants

TCB Grant - Application t7cDWmXeV8fB/rvJVPVXMw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 06/30/2025

Application Dated: 06/30/2025
ONYX Healthcare lnc.
4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist.,
New Taipei City, 231028
Taiwan
 
Attention: Andrew Wang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RZ5-VM300
Name of Grantee:  ONYX Healthcare lnc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Intel Wi-Fi 6E AX210
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.014  

Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported Body and Simultaneous SAR values are 0.02W/kg and 1.57W/kg respectively.

This module approved for mobile use with Antenna type: Dipole. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 13mm minimum test separation distance.

SAR testing was performed to demonstrate RF compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application S2fAHXkkfsjpEDJdcqH1Cw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 06/30/2025

Application Dated: 06/30/2025
ONYX Healthcare lnc.
4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist.,
New Taipei City, 231028
Taiwan
 
Attention: Andrew Wang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RZ5-VM300
Name of Grantee:  ONYX Healthcare lnc.
Equipment Class: Digital Transmission System
Notes: Intel Wi-Fi 6E AX210
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.01  
CC MO 15C 2412.0  -  2472.0 0.792  
CC MO 15C 2422.0  -  2462.0 0.602  

Power Output listed is conducted. Modular Approval. Power output has been reduced at the upper bandedge channels as shown in filings under this FCC ID. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multitransmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.59W/kg and 1.57 W/kg respectively.

This module approved for mobile use with Antenna type: Dipole. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 13mm minimum test separation distance.

SAR testing was performed to demonstrate RF compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application nK3OS7uotKfHKkE1WQWnfg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 06/30/2025

Application Dated: 06/30/2025
ONYX Healthcare lnc.
4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist.,
New Taipei City, 231028
Taiwan
 
Attention: Andrew Wang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RZ5-VM300
Name of Grantee:  ONYX Healthcare lnc.
Equipment Class: 15E 6 GHz Low Power Dual Client
Notes: Intel Wi-Fi 6E AX210
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC EP MO 15E 5955.0  -  6415.0 0.576  
CC EP MO 15E 5965.0  -  6405.0 0.717  
CC EP MO 15E 5985.0  -  6385.0 0.733  
CC EP MO 15E 6025.0  -  6345.0 0.338  
CC EP MO 15E 6535.0  -  6855.0 0.577  
CC EP MO 15E 6565.0  -  6845.0 0.783  
CC EP MO 15E 6625.0  -  6785.0 0.745  
CC EP MO 15E 6665.0  -  6665.0 0.331  
CC EP MO 15E 5955.0  -  7115.0 0.012  
CC EP MO 15E 5965.0  -  7085.0 0.024  
CC EP MO 15E 5985.0  -  7025.0 0.049  
CC EP MO 15E 6025.0  -  6985.0 0.094  

Power Output listed is EIRP. The first five rows reported above are for LPI mode and the remaining rows are for Standard mode. Modular Approval filing. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device supports 20, 40, 80,160, and 320 MHz BW modes.

This filing meets MPE requirements of KDB 447498 and can be used in mobile configurations for the following reference antenna: Intel WRF reference antenna (4.30 to 5.59 dBi).


CC: This device is certified pursuant to two different Part 15 rules sections.
EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application lmsljdPZmGBfbq9C0YFyow==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 06/30/2025

Application Dated: 06/30/2025
ONYX Healthcare lnc.
4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist.,
New Taipei City, 231028
Taiwan
 
Attention: Andrew Wang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RZ5-VM300
Name of Grantee:  ONYX Healthcare lnc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Intel Wi-Fi 6E AX210
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.166  
CC MO 15E 5190.0  -  5230.0 0.199  
CC MO 15E 5210.0  -  5210.0 0.089  
CC MO 15E 5250.0  -  5250.0 0.061  
CC MO ND 15E 5260.0  -  5320.0 0.165  
CC MO ND 15E 5270.0  -  5310.0 0.153  
CC MO ND 15E 5290.0  -  5290.0 0.084  
CC MO ND 15E 5500.0  -  5700.0 0.245  
CC MO ND 15E 5530.0  -  5690.0 0.228  
CC MO ND 15E 5710.0  -  5710.0 0.249  
CC MO ND 15E 5720.0  -  5720.0 0.134  
CC MO 15E 5745.0  -  5825.0 0.262  
CC MO 15E 5755.0  -  5795.0 0.27  
CC MO 15E 5775.0  -  5775.0 0.195  
CC MO 15E 5845.0  -  5885.0 0.332  
CC MO 15E 5835.0  -  5875.0 0.692  
CC MO 15E 5855.0  -  5855.0 0.733  
CC MO 15E 5815.0  -  5815.0 0.226  

Modular Approval. Power Output listed is conducted for UNII-1 to UNII-3 and EIRP for UNII-4 bands. UNII-4 Band is for indoor operation only. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter has 20MHz, 40MHz, 80MHz, 160 MHz bandwidth modes as described in this filing. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.78W/kg and 1.57W/kg respectively.

This module approved for mobile use with antenna type for the UNII-4 Band. (Antenna type: Dipole Antenna Wieson Part no ARY121-0009-002-H0).

This module approved for mobile use with Antenna type: Dipole. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 13mm minimum test separation distance.

SAR testing was performed to demonstrate RF compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application hn9fsgazAPjhHblVVgJwvA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 06/30/2025

Application Dated: 06/30/2025
ONYX Healthcare lnc.
4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist.,
New Taipei City, 231028
Taiwan
 
Attention: Andrew Wang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RZ5-VM300
Name of Grantee:  ONYX Healthcare lnc.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Intel Wi-Fi 6E AX210
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15B  - 


TCB Grant - Application CwG6bUtxev7GJnk8ZLTsGg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 06/30/2025

Application Dated: 06/30/2025
ONYX Healthcare lnc.
4F,No.135,Ln.235,Baoqiao Rd., Xindian Dist.,
New Taipei City, 231028
Taiwan
 
Attention: Andrew Wang , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RZ5-VM300
Name of Grantee:  ONYX Healthcare lnc.
Equipment Class: 15E 6 GHz Low Power Indoor Client
Notes: Intel Wi-Fi 6E AX210
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC EP MO 15E 5955.0  -  7115.0 0.003  
CC EP MO 15E 5965.0  -  7085.0 0.007  
CC EP MO 15E 5985.0  -  7025.0 0.013  
CC EP MO 15E 6025.0  -  6985.0 0.026  

Power Output listed is Conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. The highest reported Body and Simultaneous SAR values are 0.29 W/kg and 0.58 W/kg respectively.

This module approved for mobile use with Antenna type: Dipole. This module is approved in portable/mobile configurations with antenna Intel Antenna, Type PIFA at 13mm minimum test separation distance.

Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device supports 20, 40, 80 and 160 MHz BW modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.