FCC ID RZ51521DTT-C1
Medical Station
by ONYX Healthcare lnc.
Grantee Code: RZ5 Product Code: 1521DTTC1
Latest application date: 2015-05-05
FCC ID Device Details
| FCC ID | RZ51521DTT-C1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | RZ5 |
| Product Code | 1521DTTC1 |
| Applicant Business | ONYX Healthcare lnc. 🇹🇼 |
| Related Domains | |
| Equipment Class | Medical Station |
| Test Firm | A Test Lab Techno Corp. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2015-05-05 |
| 2402-2480 MHz | Original Equipment | 2015-05-05 |
| 5180-5240 MHz | Original Equipment | 2015-05-05 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2015-05-05 | PDF 498.5 KB |
| Internal photo | Internal Photos | 2015-05-05 | PDF 3 MB |
| External photo | External Photos | 2015-05-05 | PDF 332.1 KB |
| ID label/Location info | ID Label/Location Info | 2015-05-05 | PDF 464.8 KB |
| Test setup photo | Test Setup Photos | 2015-05-05 | PDF 173.1 KB |
| Test setup photo | Test Setup Photos | 2015-05-05 | PDF 173 KB |
| Test setup photo_Part 15E DFS | Test Setup Photos | 2015-05-05 | PDF 513.4 KB |
| Test setup photo_Part 15E U-NII | Test Setup Photos | 2015-05-05 | PDF 638.5 KB |
| Test report_P15C BT | Test Report | 2015-05-05 | PDF 748.7 KB |
| Test report_P15C WLAN + LE | Test Report | 2015-05-05 | PDF 1.6 MB |
| Test report_Part 15E DFS | Test Report | 2015-05-05 | PDF 1.6 MB |
| Test report_Part 15E UNII | Test Report | 2015-05-05 | PDF 2.3 MB |
| DTS-UNII Declaration letter | Cover Letter(s) | 2015-05-05 | PDF 230 KB |
| Declaration of Conformity (FCC subpart 18) | Cover Letter(s) | 2015-05-05 | PDF 235.8 KB |
| Declaration of authorization | Cover Letter(s) | 2015-05-05 | PDF 199.5 KB |
| Models listing Description | Cover Letter(s) | 2015-05-05 | PDF 167.3 KB |
| confidentiality | Cover Letter(s) | 2015-05-05 | PDF 775.9 KB |
| RF Exposure | RF Exposure Info | 2015-05-05 | PDF 494 KB |
| Block diagram Metadata only | Block Diagram | PDF 81.4 KB | |
| Schematics Metadata only | Schematics | PDF 1.3 MB | |
| Schematics_AW-NB110H Metadata only | Schematics | PDF 336.5 KB | |
| Operational description and Antenna Spec Metadata only | Operational Description | PDF 86.6 KB | |
| Software Security Description Metadata only | Operational Description | PDF 102.8 KB |
Application Information
| Application ID | vdWFCVXMjoSWFBPIwg8P2Q== |
|---|---|
| Final Action Date | 2015-05-05 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0022396329 |
| Model | 1521DTT-C1 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Medical Station |
| Responsible Party | Andrew Wang, Manager, andrewwang@onyx-healthcare.com |
| Technical Contact | Murphy Wang, A Test Lab Techno Corp., murphy@atl-lab.com.tw |
| Non-Technical Contact | Riva Chen, A Test Lab Techno Corp., riva.chen@atl-lab.com.tw |
| Test Firm | Fly LU, A Test Lab Techno Corp., fly@atl-lab.com.tw |
| TCB Email | certification@telefication.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| vdWFCVXMjoSWFBPIwg8P2Q== | 2015-05-05 | Original Equipment |
| prSX0vuEPbY8hiqQyqlH8Q== | 2015-05-05 | Original Equipment |
| UPXdNAnTT2VMwdX2bo1XQw== | 2015-05-05 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application vdWFCVXMjoSWFBPIwg8P2Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 05/05/2015 Application Dated: 05/05/2015 |
| ONYX Healthcare lnc. |
| 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., |
| New Taipei City, 231 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ51521DTT-C1 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Medical Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.226 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.001 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application vdWFCVXMjoSWFBPIwg8P2Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., New Taipei City, 231 Taiwan |
Date of Grant: 05/05/2015 Application Dated: 05/05/2015 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ51521DTT-C1 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Medical Station |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.226 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.001 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 05/05/2015 Application Dated: 05/05/2015 |
| ONYX Healthcare lnc. |
| 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., |
| New Taipei City, 231 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ51521DTT-C1 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Medical Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC MO | 15E | 5180.0 - 5240.0 | 0.023 | ||
| 38 CC MO ND | 15E | 5260.0 - 5320.0 | 0.023 | ||
| 38 CC MO ND | 15E | 5500.0 - 5700.0 | 0.017 | ||
| 38 CC MO | 15E | 5745.0 - 5825.0 | 0.018 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. This device has a 20/40 MHz bandwidth mode. DFS operation is slave without radar detection. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application UPXdNAnTT2VMwdX2bo1XQw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., New Taipei City, 231 Taiwan |
Date of Grant: 05/05/2015 Application Dated: 05/05/2015 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ51521DTT-C1 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Medical Station |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC MO | 15E | 5180.0 - 5240.0 | 0.023 | ||
| 38 CC MO ND | 15E | 5260.0 - 5320.0 | 0.023 | ||
| 38 CC MO ND | 15E | 5500.0 - 5700.0 | 0.017 | ||
| 38 CC MO | 15E | 5745.0 - 5825.0 | 0.018 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. This device has a 20/40 MHz bandwidth mode. DFS operation is slave without radar detection. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 05/05/2015 Application Dated: 05/05/2015 |
| ONYX Healthcare lnc. |
| 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., |
| New Taipei City, 231 Taiwan |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ51521DTT-C1 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Medical Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.003 |
| Output power listed is conducted. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application prSX0vuEPbY8hiqQyqlH8Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ONYX Healthcare lnc. 2F,No.135,Lane235,Pao chiao Rd.,XINDIAN DIST., New Taipei City, 231 Taiwan |
Date of Grant: 05/05/2015 Application Dated: 05/05/2015 |
| Attention: Andrew Wang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | RZ51521DTT-C1 |
| Name of Grantee: | ONYX Healthcare lnc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Medical Station |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.003 |
| Output power listed is conducted. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |