FCC ID RZV8136

Fixed GSM Phone

by SAGEM SA

Grantee Code: RZV   Product Code: 8136
Latest application date: 2005-05-04

FCC ID Device Details

FCC IDRZV8136
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeRZV
Product Code8136
Applicant BusinessSAGEM SA 🇫🇷
Related Domains sagem.com
Equipment ClassFixed GSM Phone
Test FirmEurofins Product Service GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2005-05-04

Exhibits

DocumentTypeAvailableFile
manualUsers Manual2005-05-04PDF 1.5 MB
PhotosInternal Photos2005-05-04PDF 1.1 MB
PhotosExternal Photos2005-05-04PDF 182.9 KB
LocID Label/Location Info2005-05-04PDF 348 KB
SmplID Label/Location Info2005-05-04PDF 111.8 KB
AntennaSpecOperational Description2005-05-04PDF 66.3 KB
PhotosTest Setup Photos2005-05-04PDF 379.4 KB
TestRpt1Test Report2005-05-04PDF 311.7 KB
TestRpt2Test Report2005-05-04PDF 1.6 MB
ConfiReqCover Letter(s)2005-05-04PDF 59.4 KB
PoACover Letter(s)2005-05-04PDF 17.6 KB
SARRF Exposure Info2005-05-04PDF 2.8 MB
Tune Up InfoParts List/Tune Up Info2005-05-04PDF 112.3 KB
BlkDia Metadata onlyBlock DiagramPDF 4.9 KB
Schem Metadata onlySchematicsPDF 619.6 KB
OpDes Metadata onlyOperational DescriptionPDF 211.7 KB
PartLst Metadata onlyParts List/Tune Up InfoPDF 188.4 KB

Application Information

Application IDVb1ehlsTL7Jfj/O61iaGlA==
Final Action Date2005-05-04
Application PurposeOriginal Equipment
Applicant FRN0010691251
Model8136
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionFixed GSM Phone
Responsible PartyMichel Stutzmann, Product Manager, michel.stutzmann@sagem.com , +33 1 4070
AgentClaus Claus Claus, SAGEM / Dr. Neuhaus Telekommunikation GmbH, claus.pauluhn@neuhaus.de , +49 (40)55304-5580
Test FirmRobert Kschiwan-Kaspar, Eurofins Product Service GmbH, rkk@eurofins.de , 49-33631-888-000
TCB Emailtzb@ets-bzt.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted for for Part 24. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not exceed a gain of 3dBi. Device has been tested for SAR compliance. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value is – Body 0.219 W/kg. This device contains 900/1800 MHz GSM functions that are not subject to this FCC filing. This filing is only applicable for PCS 1900 MHz operations.

Applications

Application IDDatePurpose
Vb1ehlsTL7Jfj/O61iaGlA==2005-05-04Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1850.2-1909.8 MHz1.090000038.0000000000Hz250KGXW24E

Grants

TCB Grant - Application Vb1ehlsTL7Jfj/O61iaGlA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 05/04/2005

Application Dated: 05/04/2005
SAGEM SA
27, Rue Leblanc
Paris, 75512
France
 
Attention: Michel Stutzmann , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RZV8136
Name of Grantee:  SAGEM SA
Equipment Class: PCS Licensed Transmitter
Notes: Fixed GSM Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 1.09 38.0  Hz 250KGXW

Power output listed is conducted for for Part 24. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not exceed a gain of 3dBi. Device has been tested for SAR compliance. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value is – Body 0.219 W/kg. This device contains 900/1800 MHz GSM functions that are not subject to this FCC filing. This filing is only applicable for PCS 1900 MHz operations.

EAS Grant - Application Vb1ehlsTL7Jfj/O61iaGlA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SAGEM SA
27, Rue Leblanc
Paris, 75512
France
  Date of Grant: 05/04/2005

Application Dated: 05/04/2005
 
Attention: Michel Stutzmann , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  RZV8136
Name of Grantee:  SAGEM SA
Equipment Class: PCS Licensed Transmitter
Notes: Fixed GSM Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 1.09 38.0  Hz 250KGXW

Power output listed is conducted for for Part 24. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not exceed a gain of 3dBi. Device has been tested for SAR compliance. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value is – Body 0.219 W/kg. This device contains 900/1800 MHz GSM functions that are not subject to this FCC filing. This filing is only applicable for PCS 1900 MHz operations.



Mail To: