FCC ID S3FAP-100

Fixed WLL Telephone (CDMA)

by AIJI System Co., Ltd.

Grantee Code: S3F   Product Code: AP100
Latest application date: 2005-04-08

FCC ID Device Details

FCC IDS3FAP-100
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeS3F
Product CodeAP100
Applicant BusinessAIJI System Co., Ltd. 🇰🇷
Related Domains aijisystem.com
Equipment ClassFixed WLL Telephone (CDMA)
Test FirmHCT Co., LTD

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.7-848.31 MHzOriginal Equipment2005-04-08

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2005-04-08PDF 2 MB
Internal PhotosInternal Photos2005-04-08PDF 1.1 MB
External PhotosExternal Photos2005-04-08PDF 678.6 KB
FCC ID Label and LocationID Label/Location Info2005-04-08PDF 216.4 KB
SAR Test Setup PhotosRF Exposure Info2005-04-08PDF 289.2 KB
Test Setup PhotosTest Setup Photos2005-04-08PDF 233 KB
Test ReportTest Report2005-04-08PDF 582.7 KB
Attestation StatementsAttestation Statements2005-04-08PDF 93.1 KB
Cover LetterCover Letter(s)2005-04-08PDF 122.1 KB
Dipole ValidationRF Exposure Info2005-04-08PDF 1.6 MB
Probe CalibrationRF Exposure Info2005-04-08PDF 1.1 MB
SAR PlotsRF Exposure Info2005-04-08PDF 1.2 MB
SAR ReportRF Exposure Info2005-04-08PDF 908.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 53.3 KB
Schematics Metadata onlySchematicsPDF 171 KB
Operational Description Metadata onlyOperational DescriptionPDF 168.1 KB
Parts List and Tune Procedure Metadata onlyParts List/Tune Up InfoPDF 235.4 KB

Application Information

Application IDi3/xae3mKKfDIjxbwLlcRA==
Final Action Date2005-04-08
Application PurposeOriginal Equipment
Applicant FRN0012937140
ModelAP-100
Frequency Range824.7-848.31 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionFixed WLL Telephone (CDMA)
Responsible PartySang Ok Lee, Director, solee031@aijisystem.com , 82 31 231 9961
AgentRandy Randy Randy, PCTEST Engineering Lab., Inc., randy@pctestlab.com , 410-290-6652
Technical ContactRandy Ortanez, PCTEST Engineering Lab., Inc., randy@pctestlab.com , 410-290-6652
Test FirmSang Lee, HCT Co., LTD, sjlee@HCT.co.kr , 82-31-645-6420
TCB Emailrandy@pctestlab.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is ERP. Device has been tested for SAR compliance. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value is – Body 1.15 W/kg.

Applications

Application IDDatePurpose
i3/xae3mKKfDIjxbwLlcRA==2005-04-08Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.7-848.31 MHz0.37600002.5000000000ppm1M27F9W22H

Grants

TCB Grant - Application i3/xae3mKKfDIjxbwLlcRA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PCTEST Engineering Laboratory, LLC
7185 Oakland Mills Road
Columbia, MD 21046
Date of Grant: 04/08/2005

Application Dated: 04/08/2005
AIJI System Co., Ltd.
Samho-Park-Tower Bldg.2F ,1120-10, Ingye-Dong,
Paldal-Gu, Suwon-City, Gyeonggi-Do, Korea
Suwon-City, 442-835
South Korea
 
Attention: Sang Ok Lee , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  S3FAP-100
Name of Grantee:  AIJI System Co., Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Fixed WLL Telephone (CDMA)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.376 2.5  PM 1M27F9W

Output is ERP. Device has been tested for SAR compliance. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value is – Body 1.15 W/kg.

EAS Grant - Application i3/xae3mKKfDIjxbwLlcRA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

AIJI System Co., Ltd.
Samho-Park-Tower Bldg.2F ,1120-10, Ingye-Dong, Paldal-Gu, Suwon-City, Gyeonggi-Do, Korea
Suwon-City, 442-835
South Korea
  Date of Grant: 04/08/2005

Application Dated: 04/08/2005
 
Attention: Sang Ok Lee , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  S3FAP-100
Name of Grantee:  AIJI System Co., Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Fixed WLL Telephone (CDMA)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.376 2.5  PM 1M27F9W

Output is ERP. Device has been tested for SAR compliance. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value is – Body 1.15 W/kg.



Mail To: