FCC ID S6C102552
Secure Methadone Delivery Technology Device
by G W Pharmaceuticals plc
Grantee Code: S6C Product Code: 102552
Latest application date: 2005-09-22
FCC ID Device Details
| FCC ID | S6C102552 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | S6C |
| Product Code | 102552 |
| Applicant Business | G W Pharmaceuticals plc 🇬🇧 |
| Related Domains | |
| Equipment Class | Secure Methadone Delivery Technology Device |
| Test Firm | RFI Global Services Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Original Equipment | 2005-09-22 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Guide part A | Users Manual | 2005-09-22 | PDF 2 MB |
| User Guide part B | Users Manual | 2005-09-22 | PDF 1.9 MB |
| User Guide part C | Users Manual | 2005-09-22 | PDF 2.4 MB |
| User Guide part D | Users Manual | 2005-09-22 | PDF 1.8 MB |
| Internal Photographs | Internal Photos | 2005-09-22 | PDF 1.2 MB |
| External Photographs | External Photos | 2005-09-22 | PDF 316.1 KB |
| ID Label | ID Label/Location Info | 2005-09-22 | PDF 1.8 MB |
| Test Report | Test Report | 2005-09-22 | PDF 812.3 KB |
| Confidentiality Request | Cover Letter(s) | 2005-09-22 | PDF 45.3 KB |
| MPE Calculation | RF Exposure Info | 2005-09-22 | PDF 32.2 KB |
| Block Diagram pt1 Metadata only | Block Diagram | PDF 61.4 KB | |
| Block Diagram pt2 Metadata only | Block Diagram | PDF 273.4 KB | |
| Schematic Diagram pt1 Metadata only | Schematics | PDF 118.8 KB | |
| Schematic Diagram pt2 Metadata only | Schematics | PDF 567.4 KB | |
| Operational Description pt1 Metadata only | Operational Description | PDF 368.6 KB | |
| Operational Description pt2 Metadata only | Operational Description | PDF 265.2 KB | |
| Parts List pt1 Metadata only | Parts List/Tune Up Info | PDF 37.5 KB | |
| Parts List pt2 Metadata only | Parts List/Tune Up Info | PDF 65.6 KB | |
| Tune Up Information Metadata only | Parts List/Tune Up Info | PDF 135.5 KB |
Application Information
| Application ID | lQfQOY+TVUCfDTjCfG7hdA== |
|---|---|
| Final Action Date | 2005-09-22 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0013105721 |
| Model | 102552 |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Secure Methadone Delivery Technology Device |
| Responsible Party | Rajiv Dave, Mr, rbd@gwpharm.com |
| Technical Contact | Rajiv Dave, G W Pharmaceuticals plc, rbd@gwpharm.com |
| Non-Technical Contact | Rajiv Dave, G W Pharmaceuticals plc, rbd@gwpharm.com |
| Test Firm | Allan Hume, RFI Global Services Ltd., alan.hume@rfi-global.com |
| TCB Email | nick.cobb@rfi-global.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output Power is ERP for part 22 (GSM850) and EIRP for part 24 (GSM1900). The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation nstructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| lQfQOY+TVUCfDTjCfG7hdA== | 2005-09-22 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application lQfQOY+TVUCfDTjCfG7hdA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL International (UK) Ltd Unit 1 - 3 Horizon Kingsland Business Park Wade Road Basingstoke, RG24 8AH United Kingdom |
Date of Grant: 09/22/2005 Application Dated: 09/22/2005 |
| G W Pharmaceuticals plc |
| Porton Down Science Park |
| Salisbury, Wiltshire, SP4 0JQ United Kingdom |
| Attention: Rajiv Dave , Mr |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | S6C102552 |
| Name of Grantee: | G W Pharmaceuticals plc |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Secure Methadone Delivery Technology Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 0.34 | 1.0 PM | 236KGXW | |
| 22H | 824.2 - 848.8 | 0.03 | 1.0 PM | 237KGXW |
| Output Power is ERP for part 22 (GSM850) and EIRP for part 24 (GSM1900). The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation nstructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application lQfQOY+TVUCfDTjCfG7hdA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
G W Pharmaceuticals plc Porton Down Science Park Salisbury, Wiltshire, SP4 0JQ United Kingdom |
Date of Grant: 09/22/2005 Application Dated: 09/22/2005 |
| Attention: Rajiv Dave , Mr |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | S6C102552 |
| Name of Grantee: | G W Pharmaceuticals plc |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Secure Methadone Delivery Technology Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 0.34 | 1.0 PM | 236KGXW | |
| 22H | 824.2 - 848.8 | 0.03 | 1.0 PM | 237KGXW |
| Output Power is ERP for part 22 (GSM850) and EIRP for part 24 (GSM1900). The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation nstructions and transmitter operating conditions for satisfying RF exposure compliance. |