FCC ID S8L-OBEMICRO1
OneBase Micro Cabinet Cell Extender OBE-1900-2411
by Andrew Corporation, Base Station Subsystems Group
Grantee Code: S8L Product Code: OBEMICRO1
Latest application date: 2008-03-31
FCC ID Device Details
| FCC ID | S8L-OBEMICRO1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | S8L |
| Product Code | OBEMICRO1 |
| Applicant Business | Andrew Corporation, Base Station Subsystems Group 🇺🇸 |
| Related Domains | |
| Equipment Class | OneBase Micro Cabinet Cell Extender OBE-1900-2411 |
| Test Firm | Advanced Compliance Laboratory |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1930-1990 MHz | Original Equipment | 2008-03-31 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2008-03-31 | PDF 2 MB |
| External Photos | External Photos | 2008-03-31 | PDF 268.2 KB |
| ID Label | ID Label/Location Info | 2008-03-31 | PDF 185.6 KB |
| Setup Photos | Test Setup Photos | 2008-03-31 | PDF 249.8 KB |
| Test Report | Test Report | 2008-03-31 | PDF 908.8 KB |
| Authorization Letter | Cover Letter(s) | 2008-03-31 | PDF 57 KB |
| Request for Confidentiality | Cover Letter(s) | 2008-03-31 | PDF 34.1 KB |
| TCB Q and A | Cover Letter(s) | 2008-03-31 | PDF 60.2 KB |
| MPE | RF Exposure Info | 2008-03-31 | PDF 172.8 KB |
Application Information
| Application ID | 9W8yY1bl9vyPvhkBSgtnWQ== |
|---|---|
| Final Action Date | 2008-03-31 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0013321245 |
| Model | -OBEMICRO1 |
| Frequency Range | 1930-1990 MHz |
| Equipment Class | AMP - Amplifier |
| Device Description | OneBase Micro Cabinet Cell Extender OBE-1900-2411 |
| Responsible Party | Gerald Reynolds, Director, Quality, gerry.reynolds@commscope.com |
| Technical Contact | Wei Li, Advanced Compliance Lab, weili@ac-lab.com |
| Non-Technical Contact | Wei Li, Advanced Compliance Lab, weili@ac-lab.com |
| Test Firm | Wei Li, Advanced Compliance Laboratory, weili3@aol.com |
| TCB Email | mike.kuo@ccsemc.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | The output level from power amplifiers is dependent upon the level of the input drive signal. Power output listed is maximum conducted composite total of all operating channels. Maximum power per carrier is 40W for CDMA and WCDMA and 25W for GSM & EDGE. Emissions listed correspond to CDMA2000, WCDMA, GSM and EDGE operation. The antenna(s) used for this transmitter must be fixed mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 9W8yY1bl9vyPvhkBSgtnWQ== | 2008-03-31 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 9W8yY1bl9vyPvhkBSgtnWQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 03/31/2008 Application Dated: 03/31/2008 |
| Andrew Corporation, Base Station Subsystems Group |
| 2601 Telecom Pkwy |
| Richardson, TX 75082-3521 |
| Attention: Gerald Reynolds , Director, Quality |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | S8L-OBEMICRO1 |
| Name of Grantee: | Andrew Corporation, Base Station Subsystems Group |
| Equipment Class: | Amplifier |
| Notes: | OneBase Micro Cabinet Cell Extender OBE-1900-2411 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1930.0 - 1990.0 | 116.0 | Amp | GXW | |
| 24E | 1930.0 - 1990.0 | 116.0 | Amp | G7W | |
| 24E | 1930.0 - 1990.0 | 116.0 | Amp | F9W |
| The output level from power amplifiers is dependent upon the level of the input drive signal. Power output listed is maximum conducted composite total of all operating channels. Maximum power per carrier is 40W for CDMA and WCDMA and 25W for GSM & EDGE. Emissions listed correspond to CDMA2000, WCDMA, GSM and EDGE operation. The antenna(s) used for this transmitter must be fixed mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). |
EAS Grant - Application 9W8yY1bl9vyPvhkBSgtnWQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Andrew Corporation, Base Station Subsystems Group 2601 Telecom Pkwy Richardson, TX 75082-3521 United States |
Date of Grant: 03/31/2008 Application Dated: 03/31/2008 |
| Attention: Gerald Reynolds , Director, Quality |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | S8L-OBEMICRO1 |
| Name of Grantee: | Andrew Corporation, Base Station Subsystems Group |
| Equipment Class: | Amplifier |
| Notes: | OneBase Micro Cabinet Cell Extender OBE-1900-2411 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1930.0 - 1990.0 | 116.0 | Amp | GXW | |
| 24E | 1930.0 - 1990.0 | 116.0 | Amp | G7W | |
| 24E | 1930.0 - 1990.0 | 116.0 | Amp | F9W |
| The output level from power amplifiers is dependent upon the level of the input drive signal. Power output listed is maximum conducted composite total of all operating channels. Maximum power per carrier is 40W for CDMA and WCDMA and 25W for GSM & EDGE. Emissions listed correspond to CDMA2000, WCDMA, GSM and EDGE operation. The antenna(s) used for this transmitter must be fixed mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). |
| Mail To: |