FCC ID SARHISENSEC199A

CDMA 1X Mobile Phone

by Hisense Communication Co., Ltd.

Grantee Code: SAR   Product Code: HISENSEC199A
Latest application date: 2009-04-07

FCC ID Device Details

FCC IDSARHISENSEC199A
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSAR
Product CodeHISENSEC199A
Applicant BusinessHisense Communication Co., Ltd. 🇨🇳
Related Domains cdma.hisense.com
Equipment ClassCDMA 1X Mobile Phone
Test FirmBay Area Compliance Laboratory

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.7-848.31 MHzOriginal Equipment2009-04-07

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2009-04-07PDF 197.1 KB
Internal PhotosInternal Photos2009-04-07PDF 798.5 KB
External PhotosExternal Photos2009-04-07PDF 574.2 KB
FCC ID Label InfoID Label/Location Info2009-04-07PDF 52.3 KB
Test Setup PhotosTest Setup Photos2009-04-07PDF 165.4 KB
Test ReportTest Report2009-04-07PDF 338.5 KB
Test Report SARRF Exposure Info2009-04-07PDF 3.2 MB
DoC Attestation LetterAttestation Statements2009-04-07PDF 370.1 KB
Authorization LetterCover Letter(s)2009-04-07PDF 1.3 MB
Confidentiality Request LetterCover Letter(s)2009-04-07PDF 1.2 MB

Application Information

Application ID4db179bBalenojOamyGY3A==
Final Action Date2009-04-07
Application PurposeOriginal Equipment
Applicant FRN0011142353
ModelHISENSEC199A
Frequency Range824.7-848.31 MHz
Equipment ClassTNE - Licensed Non-Broadcast Transmitter Held to Ear
Device DescriptionCDMA 1X Mobile Phone
Responsible PartyHaining Wang, wanghaining@cdma.hisense.com , 865326761747
Test FirmJohn Chan, Bay Area Compliance Laboratory, bacl.regulatory@baclcorp.com , 408-732-9162
TCB Emailatory@baclcorp.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the end users’ body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance SAR. The highest reported SAR values are: Part 22H - Head: 1.02 W/kg, Body-worn: 0.514 W/kg.

Applications

Application IDDatePurpose
4db179bBalenojOamyGY3A==2009-04-07Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.7-848.31 MHz0.28000002.5000000000ppm1M28F9W22H

Grants

TCB Grant - Application 4db179bBalenojOamyGY3A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 04/07/2009

Application Dated: 04/07/2009
Hisense Communication Co., Ltd.
Hisense Infor. Industrial Park
Economic Technology Dev. District
Qingdao, 266510
China
 
Attention: Haining Wang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SARHISENSEC199A
Name of Grantee:  Hisense Communication Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Ear
Notes: CDMA 1X Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.28 2.5  PM 1M28F9W

Output power listed is ERP. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the end users’ body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance SAR. The highest reported SAR values are: Part 22H - Head: 1.02 W/kg, Body-worn: 0.514 W/kg.

EAS Grant - Application 4db179bBalenojOamyGY3A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hisense Communication Co., Ltd.
Hisense Infor. Industrial Park Economic Technology Dev. District
Qingdao, 266510
China
  Date of Grant: 04/07/2009

Application Dated: 04/07/2009
 
Attention: Haining Wang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SARHISENSEC199A
Name of Grantee:  Hisense Communication Co., Ltd.
Equipment Class: Licensed Non-Broadcast Transmitter Held to Ear
Notes: CDMA 1X Mobile Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.28 2.5  PM 1M28F9W

Output power listed is ERP. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the end users’ body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance SAR. The highest reported SAR values are: Part 22H - Head: 1.02 W/kg, Body-worn: 0.514 W/kg.