FCC ID SCEAR3700
Repeater
by Powerwave Technologies
Grantee Code: SCE Product Code: AR3700
Latest application date: 2006-07-26
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1850-1910 MHz | Original Equipment | 2006-07-26 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2006-07-26 | PDF 1.9 MB |
| External photos | External Photos | 2006-07-26 | PDF 242.8 KB |
| Photo of enclosure lock | External Photos | 2006-07-26 | PDF 248.7 KB |
| Label and location | ID Label/Location Info | 2006-07-26 | PDF 93.5 KB |
| Operational description | Operational Description | 2006-07-26 | PDF 57.8 KB |
| Setup photos | Test Setup Photos | 2006-07-26 | PDF 228.1 KB |
| Test report | Test Report | 2006-07-26 | PDF 787.5 KB |
| Fiber not implemented | Attestation Statements | 2006-07-26 | PDF 18.4 KB |
| Confidentiality request | Cover Letter(s) | 2006-07-26 | PDF 23 KB |
| Correspondence | Cover Letter(s) | 2006-07-26 | PDF 37.7 KB |
| Passive filter specification | Cover Letter(s) | 2006-07-26 | PDF 81.2 KB |
| DC power to final RF stage | Parts List/Tune Up Info | 2006-07-26 | PDF 47.7 KB |
| Tune up information | Parts List/Tune Up Info | 2006-07-26 | PDF 145.1 KB |
| Internal photos Metadata only | Internal Photos | PDF 1.5 MB | |
| Block diagram Metadata only | Block Diagram | PDF 29.9 KB | |
| Schematics Metadata only | Schematics | PDF 1.9 MB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 118.9 KB |
Application Information
| Application ID | ks6MpRqR+vFpoZxFYtaXAw== |
|---|---|
| Final Action Date | 2006-07-26 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0010507739 |
| Model | AR3700 |
| Frequency Range | 1850-1910 MHz |
| Equipment Class | AMP - Amplifier |
| Device Description | Repeater |
| Responsible Party | Anders Hagberg, Product Manager, anders.hagberg@pwav.com |
| Technical Contact | Thomas Edin, Powerwave Technologies, thomas.edin@pwav.com |
| Non-Technical Contact | Thomas Edin, Powerwave Technologies, thomas.edin@pwav.com |
| Test Firm | Niklas Bostrom, Intertek SEMKO AB, niklas.bostrom@intertek.com |
| TCB Email | TCB_Admin@intertek.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output is conducted. User instructions must be followed to select output power, antenna gain and cable loss used for this amplifier with antenna(s) on fixed-mounted outdoor or indoor permanent structures. Fixed-mounted indoor installations must provide a separation distance from the antenna(s) of at least 20 cm from all persons during normal operation. The maximum radiated output at each antenna must satisfy the MPE Categorical Exclusion Requirements of §2.1091. For fixed-mounted outdoor applications, RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| ks6MpRqR+vFpoZxFYtaXAw== | 2006-07-26 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application ks6MpRqR+vFpoZxFYtaXAw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Intertek Testing Services NA, Inc. 70 Codman Hill Road Boxborough, MA 01719 |
Date of Grant: 07/26/2006 Application Dated: 07/26/2006 |
| Powerwave Technologies |
| Antennvagen 6 |
| 187 80 Taby, Sweden |
| Attention: Anders Hagberg , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SCEAR3700 |
| Name of Grantee: | Powerwave Technologies |
| Equipment Class: | Amplifier |
| Notes: | Repeater |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 24E | 1850.0 - 1910.0 | 2.0 | G7W | |
| BC | 24E | 1850.0 - 1910.0 | 2.0 | GXW | |
| BC | 24E | 1930.0 - 1990.0 | 2.0 | G7W | |
| BC | 24E | 1930.0 - 1990.0 | 2.0 | GXW |
| Output is conducted. User instructions must be followed to select output power, antenna gain and cable loss used for this amplifier with antenna(s) on fixed-mounted outdoor or indoor permanent structures. Fixed-mounted indoor installations must provide a separation distance from the antenna(s) of at least 20 cm from all persons during normal operation. The maximum radiated output at each antenna must satisfy the MPE Categorical Exclusion Requirements of §2.1091. For fixed-mounted outdoor applications, RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application ks6MpRqR+vFpoZxFYtaXAw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Powerwave Technologies Antennvagen 6 187 80 Taby, Sweden |
Date of Grant: 07/26/2006 Application Dated: 07/26/2006 |
| Attention: Anders Hagberg , Product Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SCEAR3700 |
| Name of Grantee: | Powerwave Technologies |
| Equipment Class: | Amplifier |
| Notes: | Repeater |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 24E | 1850.0 - 1910.0 | 2.0 | G7W | |
| BC | 24E | 1850.0 - 1910.0 | 2.0 | GXW | |
| BC | 24E | 1930.0 - 1990.0 | 2.0 | G7W | |
| BC | 24E | 1930.0 - 1990.0 | 2.0 | GXW |
| Output is conducted. User instructions must be followed to select output power, antenna gain and cable loss used for this amplifier with antenna(s) on fixed-mounted outdoor or indoor permanent structures. Fixed-mounted indoor installations must provide a separation distance from the antenna(s) of at least 20 cm from all persons during normal operation. The maximum radiated output at each antenna must satisfy the MPE Categorical Exclusion Requirements of §2.1091. For fixed-mounted outdoor applications, RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |