FCC ID SDBAMDS1000TR-1

ELECTRICITY METER TRANSCEIVER

by Sensus Metering Systems Inc.

Grantee Code: SDB   Product Code: AMDS1000TR1
Latest application date: 2005-04-28

FCC ID Device Details

FCC IDSDBAMDS1000TR-1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSDB
Product CodeAMDS1000TR1
Applicant BusinessSensus Metering Systems Inc. 🇺🇸
Related Domains xylem.com
Equipment ClassELECTRICITY METER TRANSCEIVER
Test FirmAdvanced Compliance Solutions, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
896.05-901 MHzOriginal Equipment2005-04-28

Exhibits

DocumentTypeAvailableFile
USERS MANUALUsers Manual2005-04-28PDF 58.9 KB
INTERNAL PHOTOSInternal Photos2005-04-28PDF 436.9 KB
EXTERNAL PHOTOSExternal Photos2005-04-28PDF 97 KB
ID LABELID Label/Location Info2005-04-28PDF 186 KB
TEST REPORTTest Report2005-04-28PDF 388 KB
CONFIDENTIALITY LETTERCover Letter(s)2005-04-28PDF 19.8 KB
RF EXPOSURERF Exposure Info2005-04-28PDF 31.2 KB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 32.7 KB
SCHEMATICS Metadata onlySchematicsPDF 122.9 KB
OPERATIONAL DESCRIPTION Metadata onlyOperational DescriptionPDF 508.9 KB
PARTS LIST Metadata onlyParts List/Tune Up InfoPDF 2.6 MB
TUNE UP Metadata onlyParts List/Tune Up InfoPDF 148.5 KB

Application Information

Application IDqI5yidZmK9a3tudRlUSSTw==
Final Action Date2005-04-28
Application PurposeOriginal Equipment
Applicant FRN0003180007
ModelAMDS1000TR-1
Frequency Range896.05-901 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionELECTRICITY METER TRANSCEIVER
Responsible PartyMilton Ray Britt, Sr. Director, Global System Test, ray.britt@xylem.com , 919-317-6335
Test FirmDouglas Massey, Advanced Compliance Solutions, Inc., dmassey@acstestlab.com , 770-831-8048
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. The antenna gain must not exceed 0dBi. The antenna(s)used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF esposure compliance.

Applications

Application IDDatePurpose
qI5yidZmK9a3tudRlUSSTw==2005-04-28Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
896.05-901 MHz11.5ppm9K60F2D9
896.05-901 MHz11.5ppm1K10F2D9
896.05-901 MHz11.5ppm4K80F2D9
901-902 MHz11ppm1K10F2D24D
901-902 MHz11ppm4K80F2D24D
930-931 MHz11ppm5K90F1D24D
932-932.5 MHz11.5ppm9K60F2D101C
932-932.5 MHz11.5ppm1K10F2D101C
932-932.5 MHz11.5ppm4K80F2D101C
935-940 MHz11.5ppm5K90F1D9
940-941 MHz11ppm5K90F1D24D
941-941.5 MHz11.5ppm5K90F1D101C

Grants

TCB Grant - Application qI5yidZmK9a3tudRlUSSTw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 04/28/2005

Application Dated: 04/28/2005
Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
 
Attention: Milton Britt , Sr. Director, Global System Test

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBAMDS1000TR-1
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: ELECTRICITY METER TRANSCEIVER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 1.0 1.0  PM 9K60F2D
24D 901.0  -  902.0 1.0 1.0  PM 1K10F2D
24D 901.0  -  902.0 1.0 1.0  PM 4K80F2D
24D 930.0  -  931.0 1.0 1.0  PM 5K90F1D
24D 940.0  -  941.0 1.0 1.0  PM 5K90F1D
90 896.05  -  901.0 1.0 1.5  PM 9K60F2D
90 896.05  -  901.0 1.0 1.5  PM 1K10F2D
90 896.05  -  901.0 1.0 1.5  PM 4K80F2D
90 935.0  -  940.0 1.0 1.5  PM 5K90F1D
101C 932.0  -  932.5 1.0 1.5  PM 9K60F2D
101C 932.0  -  932.5 1.0 1.5  PM 1K10F2D
101C 932.0  -  932.5 1.0 1.5  PM 4K80F2D
101C 941.0  -  941.5 1.0 1.5  PM 5K90F1D

Power listed is conducted. The antenna gain must not exceed 0dBi. The antenna(s)used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF esposure compliance.

EAS Grant - Application qI5yidZmK9a3tudRlUSSTw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
United States
  Date of Grant: 04/28/2005

Application Dated: 04/28/2005
 
Attention: Milton Britt , Sr. Director, Global System Test

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBAMDS1000TR-1
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: ELECTRICITY METER TRANSCEIVER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 1.0 1.0  PM 9K60F2D
24D 901.0  -  902.0 1.0 1.0  PM 1K10F2D
24D 901.0  -  902.0 1.0 1.0  PM 4K80F2D
24D 930.0  -  931.0 1.0 1.0  PM 5K90F1D
24D 940.0  -  941.0 1.0 1.0  PM 5K90F1D
90 896.05  -  901.0 1.0 1.5  PM 9K60F2D
90 896.05  -  901.0 1.0 1.5  PM 1K10F2D
90 896.05  -  901.0 1.0 1.5  PM 4K80F2D
90 935.0  -  940.0 1.0 1.5  PM 5K90F1D
101C 932.0  -  932.5 1.0 1.5  PM 9K60F2D
101C 932.0  -  932.5 1.0 1.5  PM 1K10F2D
101C 932.0  -  932.5 1.0 1.5  PM 4K80F2D
101C 941.0  -  941.5 1.0 1.5  PM 5K90F1D

Power listed is conducted. The antenna gain must not exceed 0dBi. The antenna(s)used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with installation instructions and transmitter operating conditions for satisfying RF esposure compliance.



Mail To: