FCC ID SDBCPTP100A

Cathodic Protection Test Point

by Sensus Metering Systems Inc.

Grantee Code: SDB   Product Code: CPTP100A
Latest application date: 2025-03-25

FCC ID Device Details

FCC IDSDBCPTP100A
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSDB
Product CodeCPTP100A
Applicant BusinessSensus Metering Systems Inc. 🇺🇸
Related Domains xylem.com
Equipment ClassCathodic Protection Test Point
Test FirmTUV SUD America Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
901-902 MHzOriginal Equipment2025-03-25

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2025-03-25PDF 743.3 KB
External PhotosExternal Photos2025-03-25PDF 676.6 KB
Label InformationID Label/Location Info2025-03-25PDF 241.9 KB
Test Setup PhotosTest Setup Photos2025-03-25PDF 1.5 MB
Test ReportTest Report2025-03-25PDF 3.1 MB
2.911(d)(5)(i)-(ii) Covered EquipmentAttestation Statements2025-03-25PDF 105.3 KB
2.911(d)(7) Agent of ServiceAttestation Statements2025-03-25PDF 171.2 KB
Agency AgreementCover Letter(s)2025-03-25PDF 178.3 KB
Confidentiality RequestCover Letter(s)2025-03-25PDF 207 KB
Cover LetterCover Letter(s)2025-03-25PDF 29.4 KB
NDA AgreementCover Letter(s)2025-03-25PDF 42.4 KB
RF ExposureRF Exposure Info2025-03-25PDF 124 KB
Internal Photos Metadata onlyInternal PhotosPDF 942.4 KB
Block Diagram Metadata onlyBlock DiagramPDF 112.1 KB
Schematics Metadata onlySchematicsPDF 2.8 MB
Operational Description Metadata onlyOperational DescriptionPDF 233.8 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 230.7 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 716.7 KB

Application Information

Application IDxG+8KCU1CJZb+9kVULM9Ag==
Final Action Date2025-03-25
Application PurposeOriginal Equipment
Applicant FRN0003180007
ModelCPTP100A
Frequency Range901-902 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionCathodic Protection Test Point
Responsible PartyRay Britt, Senior Director, Global System Test, ray.britt@xylem.com , 919-665-7878
AgentRossana Rossana Rossana, TUV SUD America
Test FirmWilliam Elliott, TUV SUD America Inc., William.Elliott@tuvsud.com , 813-284-2736
TCB Emailjeff.woods@tuvsud.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
xG+8KCU1CJZb+9kVULM9Ag==2025-03-25Original Equipment

Equipment Authorization

FrequencyOutputToleranceRules
901-902 MHz11ppm1
928.85-929 MHz0.9251ppm
930-931 MHz0.9181ppm
932-932.5 MHz0.9061ppm
940-941 MHz0.8711ppm
941-941.5 MHz0.8671ppm
959.85-960 MHz0.8051ppm

Grants

TCB Grant - Application xG+8KCU1CJZb+9kVULM9Ag==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD America Inc.
401 Edgewater Place Suite #500
Wakefield, MA 01880
Date of Grant: 03/25/2025

Application Dated: 03/25/2025
Sensus Metering Systems Inc.
637 Davis Drive
Morrisville, NC 27560
 
Attention: Ray Britt , Senior Director, Global System Test

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBCPTP100A
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Cathodic Protection Test Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 1.0 1.0  PM 9K60F2D
24D 901.0  -  902.0 1.0 1.0  PM 4K80F2D
24D 901.0  -  902.0 1.0 1.0  PM 1K10F2D
24D 930.0  -  931.0 0.918 1.0  PM 5K90F1D
24D 930.0  -  931.0 0.918 1.0  PM 11K8F1D
24D 940.0  -  941.0 0.871 1.0  PM 5K90F1D
24D 940.0  -  941.0 0.871 1.0  PM 11K8F1D
101C 928.85  -  929.0 0.925 1.0  PM 9K60F2D
101C 928.85  -  929.0 0.925 1.0  PM 4K80F2D
101C 928.85  -  929.0 0.925 1.0  PM 1K10F2D
101C 932.0  -  932.5 0.906 1.0  PM 9K60F2D
101C 932.0  -  932.5 0.906 1.0  PM 4K80F2D
101C 932.0  -  932.5 0.906 1.0  PM 1K10F2D
101C 941.0  -  941.5 0.867 1.0  PM 5K90F1D
101C 941.0  -  941.5 0.867 1.0  PM 11K8F1D
101C 959.85  -  960.0 0.805 1.0  PM 5K90F1D
101C 959.85  -  960.0 0.805 1.0  PM 11K8F1D

Power listed is conducted. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.