FCC ID SDBGFL2CI

Utility Meter Transceiver

by Sensus Metering Systems Inc.

Grantee Code: SDB   Product Code: GFL2CI
Latest application date: 2011-10-11

FCC ID Device Details

FCC IDSDBGFL2CI
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSDB
Product CodeGFL2CI
Applicant BusinessSensus Metering Systems Inc. 🇺🇸
Related Domains sensus.com
Equipment ClassUtility Meter Transceiver
Test FirmAdvanced Compliance Solutions, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
896.019-901 MHzOriginal Equipment2011-10-11

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2011-10-11PDF 17.5 KB
Label InformationID Label/Location Info2011-10-11PDF 115.4 KB
Test Setup PhotosTest Setup Photos2011-10-11PDF 576.4 KB
Test Report 1 of 2Test Report2011-10-11PDF 1.1 MB
Test Report 2 of 2Test Report2011-10-11PDF 127.1 KB
Agency AgreementCover Letter(s)2011-10-11PDF 59.6 KB
Confidentiality RequestCover Letter(s)2011-10-11PDF 37 KB
FCC Cover LetterCover Letter(s)2011-10-11PDF 17 KB
Modular Approval LetterCover Letter(s)2011-10-11PDF 46.5 KB
NDA LetterCover Letter(s)2011-10-11PDF 1.6 MB
RF ExposureRF Exposure Info2011-10-11PDF 25.6 KB

Application Information

Application IDv7sCqR7G0AL7z6YFpt0RmA==
Final Action Date2011-10-11
Application PurposeOriginal Equipment
Applicant FRN0003180007
ModelGFL2CI
Frequency Range896.019-901 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionUtility Meter Transceiver
Responsible PartyRichard Daniel, Director, Engineering NPI and Project Management, Richard.Daniel@sensus.com , 919-424-8912
AgentSam Sam Sam, Advanced Compliance Solutions, Inc., swismer@acstestlab.com , 770-831-8048
Test FirmRandy Abernathy, Advanced Compliance Solutions, Inc., rabernathy@acstestlab.com , 770-831-8048
TCB Emailjwoods@acstestlab.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsModular Approval. Power listed is conducted. Device must operate with a source-based, time-averaged duty cycle not to exceed 4.5%, controlled by firmware or software. This Modular Approval is limited to installation for mobile and fixed applications only. This grant is valid only when the device is installed by the grantee or contractors employed by the grantee who are instructed to ensure that the end-user has no manual instructions to remove or install the device. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
v7sCqR7G0AL7z6YFpt0RmA==2011-10-11Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
896.019-901 MHz0.71.5ppm4K80F2D9
896.019-901 MHz0.71.5ppm9K60F2D9
896.019-901 MHz0.71.5ppm1K10F2D9
901-902 MHz0.71ppm4K80F2D24D
928.85-929 MHz0.71.5ppm9K60F2D101C
928.85-929 MHz0.71.5ppm1K10F2D101C
928.85-929 MHz0.71.5ppm4K80F2D101C
930-931 MHz0.71ppm5K90F1D24D
930-931 MHz0.71ppm11K8F1D24D
932-932.5 MHz0.71.5ppm9K60F2D101C
932-932.5 MHz0.71.5ppm1K10F2D101C
932-932.5 MHz0.71.5ppm4K80F2D101C
935-940 MHz0.71.5ppm5K90F1D9
940-941 MHz0.71ppm5K90F1D24D
940-941 MHz0.71ppm11K8F1D24D
941-941.5 MHz0.71.5ppm5K90F1D101C
941-941.5 MHz0.71.5ppm11K8F1D101C
959.85-959.95 MHz0.71.5ppm5K90F1D101C
959.85-959.95 MHz0.71.5ppm11K8F1D101C

Grants

TCB Grant - Application v7sCqR7G0AL7z6YFpt0RmA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 10/11/2011

Application Dated: 10/10/2011
Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
 
Attention: Richard Daniel , Director, Engineering NPI and Project Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBGFL2CI
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Utility Meter Transceiver
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 0.7 1.0  PM 9K60F2D
24D 901.0  -  902.0 0.7 1.0  PM 1K10F2D
24D 901.0  -  902.0 0.7 1.0  PM 4K80F2D
24D 930.0  -  931.0 0.7 1.0  PM 5K90F1D
24D 930.0  -  931.0 0.7 1.0  PM 11K8F1D
24D 940.0  -  941.0 0.7 1.0  PM 5K90F1D
24D 940.0  -  941.0 0.7 1.0  PM 11K8F1D
90 896.01875  -  901.0 0.7 1.5  PM 9K60F2D
90 896.01875  -  901.0 0.7 1.5  PM 1K10F2D
90 896.01875  -  901.0 0.7 1.5  PM 4K80F2D
90 935.0  -  940.0 0.7 1.5  PM 5K90F1D
101C 928.85  -  929.0 0.7 1.5  PM 9K60F2D
101C 928.85  -  929.0 0.7 1.5  PM 1K10F2D
101C 928.85  -  929.0 0.7 1.5  PM 4K80F2D
101C 932.0  -  932.5 0.7 1.5  PM 9K60F2D
101C 932.0  -  932.5 0.7 1.5  PM 1K10F2D
101C 932.0  -  932.5 0.7 1.5  PM 4K80F2D
101C 941.0  -  941.5 0.7 1.5  PM 5K90F1D
101C 941.0  -  941.5 0.7 1.5  PM 11K8F1D
101C 959.85  -  959.95 0.7 1.5  PM 5K90F1D
101C 959.85  -  959.95 0.7 1.5  PM 11K8F1D

Modular Approval. Power listed is conducted. Device must operate with a source-based, time-averaged duty cycle not to exceed 4.5%, controlled by firmware or software. This Modular Approval is limited to installation for mobile and fixed applications only. This grant is valid only when the device is installed by the grantee or contractors employed by the grantee who are instructed to ensure that the end-user has no manual instructions to remove or install the device. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

EAS Grant - Application v7sCqR7G0AL7z6YFpt0RmA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
United States
  Date of Grant: 10/11/2011

Application Dated: 10/10/2011
 
Attention: Richard Daniel , Director, Engineering NPI and Project Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBGFL2CI
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Utility Meter Transceiver
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 0.7 1.0  PM 9K60F2D
24D 901.0  -  902.0 0.7 1.0  PM 1K10F2D
24D 901.0  -  902.0 0.7 1.0  PM 4K80F2D
24D 930.0  -  931.0 0.7 1.0  PM 5K90F1D
24D 930.0  -  931.0 0.7 1.0  PM 11K8F1D
24D 940.0  -  941.0 0.7 1.0  PM 5K90F1D
24D 940.0  -  941.0 0.7 1.0  PM 11K8F1D
90 896.01875  -  901.0 0.7 1.5  PM 9K60F2D
90 896.01875  -  901.0 0.7 1.5  PM 1K10F2D
90 896.01875  -  901.0 0.7 1.5  PM 4K80F2D
90 935.0  -  940.0 0.7 1.5  PM 5K90F1D
101C 928.85  -  929.0 0.7 1.5  PM 9K60F2D
101C 928.85  -  929.0 0.7 1.5  PM 1K10F2D
101C 928.85  -  929.0 0.7 1.5  PM 4K80F2D
101C 932.0  -  932.5 0.7 1.5  PM 9K60F2D
101C 932.0  -  932.5 0.7 1.5  PM 1K10F2D
101C 932.0  -  932.5 0.7 1.5  PM 4K80F2D
101C 941.0  -  941.5 0.7 1.5  PM 5K90F1D
101C 941.0  -  941.5 0.7 1.5  PM 11K8F1D
101C 959.85  -  959.95 0.7 1.5  PM 5K90F1D
101C 959.85  -  959.95 0.7 1.5  PM 11K8F1D

Modular Approval. Power listed is conducted. Device must operate with a source-based, time-averaged duty cycle not to exceed 4.5%, controlled by firmware or software. This Modular Approval is limited to installation for mobile and fixed applications only. This grant is valid only when the device is installed by the grantee or contractors employed by the grantee who are instructed to ensure that the end-user has no manual instructions to remove or install the device. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.



Mail To: