FCC ID SDBM400BV02

Basestation

by Sensus Metering Systems Inc.

Grantee Code: SDB   Product Code: M400BV02
Latest application date: 2013-05-19

FCC ID Device Details

FCC IDSDBM400BV02
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSDB
Product CodeM400BV02
Applicant BusinessSensus Metering Systems Inc. 🇺🇸
Related Domains sensus.com
Equipment ClassBasestation
Test FirmAdvanced Compliance Solutions, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
941-941.5 MHzOriginal Equipment2013-05-19

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2013-05-19PDF 388.3 KB
Label InformationID Label/Location Info2013-05-19PDF 47.5 KB
Test Setup PhotosTest Setup Photos2013-05-19PDF 283.5 KB
Test ReportTest Report2013-05-19PDF 261.5 KB
Agency AgreementCover Letter(s)2013-05-19PDF 65.3 KB
Confidentiality REquestCover Letter(s)2013-05-19PDF 34.3 KB
FCC Cover LetterCover Letter(s)2013-05-19PDF 18.1 KB
NDA LetterCover Letter(s)2013-05-19PDF 220.7 KB
RF ExposureRF Exposure Info2013-05-19PDF 27.6 KB

Application Information

Application IDWNPF1hiq5uJnDXtiAlfITQ==
Final Action Date2013-05-19
Application PurposeOriginal Equipment
Applicant FRN0003180007
ModelM400BV02
Frequency Range941-941.5 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionBasestation
Responsible PartyRichard Daniel, Director, Engineering NPI and Project Management, Richard.Daniel@sensus.com , 919-424-8912
AgentSam Sam Sam, Advanced Compliance Solutions, Inc.
Test FirmSam Wismer, Advanced Compliance Solutions, Inc., swismer@acstestlab.com , 561-961-5585
TCB Emailjwoods@acstestlab.com
TCB ScopeB4: Microwave Radio Services equipment in 47 CFR Parts 27, 74, 101
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. Device is limited to fixed applications only and must be professionally installed. The transmitter must be installed to provide a separation distance of at least 120 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
WNPF1hiq5uJnDXtiAlfITQ==2013-05-19Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
941-941.5 MHz6.68341.5ppm5K90F1D101
941-941.5 MHz6.68341.5ppm11K8F1D101
941-941.5 MHz6.68341.5ppm8K75F1D101
941-941.5 MHz6.68341.5ppm17K5F1D101

Grants

TCB Grant - Application WNPF1hiq5uJnDXtiAlfITQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 05/19/2013

Application Dated: 05/17/2013
Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
 
Attention: Richard Daniel , Director, Engineering NPI and Project Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBM400BV02
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Basestation
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
101 941.0  -  941.5 6.6834 1.5  PM 5K90F1D
101 941.0  -  941.5 6.6834 1.5  PM 11K8F1D
101 941.0  -  941.5 6.6834 1.5  PM 8K75F1D
101 941.0  -  941.5 6.6834 1.5  PM 17K5F1D

Power listed is conducted. Device is limited to fixed applications only and must be professionally installed. The transmitter must be installed to provide a separation distance of at least 120 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

EAS Grant - Application WNPF1hiq5uJnDXtiAlfITQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
United States
  Date of Grant: 05/19/2013

Application Dated: 05/17/2013
 
Attention: Richard Daniel , Director, Engineering NPI and Project Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBM400BV02
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Basestation
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
101 941.0  -  941.5 6.6834 1.5  PM 5K90F1D
101 941.0  -  941.5 6.6834 1.5  PM 11K8F1D
101 941.0  -  941.5 6.6834 1.5  PM 8K75F1D
101 941.0  -  941.5 6.6834 1.5  PM 17K5F1D

Power listed is conducted. Device is limited to fixed applications only and must be professionally installed. The transmitter must be installed to provide a separation distance of at least 120 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.



Mail To: