FCC ID SDBM400V00
Base Station Transceiver
by Sensus Metering Systems Inc.
Grantee Code: SDB Product Code: M400V00
Latest application date: 2013-04-12
FCC ID Device Details
| FCC ID | SDBM400V00 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | SDB |
| Product Code | M400V00 |
| Applicant Business | Sensus Metering Systems Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | Base Station Transceiver |
| Test Firm | Advanced Compliance Solutions, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 930-931 MHz | Original Equipment | 2013-04-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos | External Photos | 2013-04-12 | PDF 773 KB |
| Label Information | ID Label/Location Info | 2013-04-12 | PDF 78.2 KB |
| Test Setup Photos | Test Setup Photos | 2013-04-12 | PDF 234.5 KB |
| Test Report | Test Report | 2013-04-12 | PDF 1.4 MB |
| Agency Agreement | Cover Letter(s) | 2013-04-12 | PDF 65.8 KB |
| Confidentiality Request | Cover Letter(s) | 2013-04-12 | PDF 34.4 KB |
| FCC Cover Letter | Cover Letter(s) | 2013-04-12 | PDF 21 KB |
| NDA Letter | Cover Letter(s) | 2013-04-12 | PDF 179.4 KB |
| RF Exposure | RF Exposure Info | 2013-04-12 | PDF 38.3 KB |
Application Information
| Application ID | bkC3i/A2KxTZcIxXaKatyQ== |
|---|---|
| Final Action Date | 2013-04-12 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0003180007 |
| Model | M400V00 |
| Frequency Range | 930-931 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Base Station Transceiver |
| Responsible Party | Richard Daniel, Director, Engineering NPI and Project Management, Richard.Daniel@sensus.com |
| Agent | Sam Sam Sam, Advanced Compliance Solutions, Inc. |
| Test Firm | Sam Wismer, Advanced Compliance Solutions, Inc., swismer@acstestlab.com |
| TCB Email | jwoods@acstestlab.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. Device is limited to fixed applications only. The transmitter must be installed to provide a separation distance of at least 152 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| bkC3i/A2KxTZcIxXaKatyQ== | 2013-04-12 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 930-931 MHz | 10.52 | 1ppm | 8K75F1D | 24D |
| 930-931 MHz | 10.52 | 1ppm | 17K5F1D | 24D |
| 940-941 MHz | 10.52 | 1ppm | 5K90F1D | 24D |
| 940-941 MHz | 10.52 | 1ppm | 11K8F1D | 24D |
| 940-941 MHz | 10.52 | 1ppm | 8K75F1D | 24D |
| 940-941 MHz | 10.52 | 1ppm | 17K5F1D | 24D |
| 941-941.5 MHz | 10.52 | 1.5ppm | 11K8F1D | 101C |
| 941-941.5 MHz | 10.52 | 1.5ppm | 8K75F1D | 101C |
| 941-941.5 MHz | 10.52 | 1.5ppm | 17K5F1D | 101C |
| 941-941.5 MHz | 10.52 | 1.5ppm | 5K90F1D | 101C |
| 952-953 MHz | 10.52 | 1.5ppm | 5K90F1D | 101C |
| 952-953 MHz | 10.52 | 1.5ppm | 11K8F1D | 101C |
| 952-953 MHz | 10.52 | 1.5ppm | 8K75F1D | 101C |
| 952-953 MHz | 10.52 | 1.5ppm | 17K5F1D | 101C |
| 959.85-960 MHz | 10.52 | 1.5ppm | 5K90F1D | 101C |
| 959.85-960 MHz | 10.52 | 1.5ppm | 11K8F1D | 101C |
| 959.85-960 MHz | 10.52 | 1.5ppm | 8K75F1D | 101C |
| 959.85-960 MHz | 10.52 | 1.5ppm | 17K5F1D | 101C |
Grants
TCB Grant - Application bkC3i/A2KxTZcIxXaKatyQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Advanced Compliance Solutions, Inc. 5015 B.U. Bowman Drive Buford, GA 30518 |
Date of Grant: 04/12/2013 Application Dated: 04/12/2013 |
| Sensus Metering Systems Inc. |
| 639 Davis Drive |
| Morrisville, NC 27560 |
| Attention: Richard Daniel , Director, Engineering NPI and Project Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SDBM400V00 |
| Name of Grantee: | Sensus Metering Systems Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Base Station Transceiver |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 930.0 - 931.0 | 10.52 | 1.0 PM | 5K90F1D | |
| 24D | 930.0 - 931.0 | 10.52 | 1.0 PM | 11K8F1D | |
| 24D | 930.0 - 931.0 | 10.52 | 1.0 PM | 8K75F1D | |
| 24D | 930.0 - 931.0 | 10.52 | 1.0 PM | 17K5F1D | |
| 24D | 940.0 - 941.0 | 10.52 | 1.0 PM | 5K90F1D | |
| 24D | 940.0 - 941.0 | 10.52 | 1.0 PM | 11K8F1D | |
| 24D | 940.0 - 941.0 | 10.52 | 1.0 PM | 8K75F1D | |
| 24D | 940.0 - 941.0 | 10.52 | 1.0 PM | 17K5F1D | |
| 101C | 941.0 - 941.5 | 10.52 | 1.5 PM | 5K90F1D | |
| 101C | 941.0 - 941.5 | 10.52 | 1.5 PM | 11K8F1D | |
| 101C | 941.0 - 941.5 | 10.52 | 1.5 PM | 8K75F1D | |
| 101C | 941.0 - 941.5 | 10.52 | 1.5 PM | 17K5F1D | |
| 101C | 952.0 - 953.0 | 10.52 | 1.5 PM | 5K90F1D | |
| 101C | 952.0 - 953.0 | 10.52 | 1.5 PM | 11K8F1D | |
| 101C | 952.0 - 953.0 | 10.52 | 1.5 PM | 8K75F1D | |
| 101C | 952.0 - 953.0 | 10.52 | 1.5 PM | 17K5F1D | |
| 101C | 959.85 - 960.0 | 10.52 | 1.5 PM | 5K90F1D | |
| 101C | 959.85 - 960.0 | 10.52 | 1.5 PM | 11K8F1D | |
| 101C | 959.85 - 960.0 | 10.52 | 1.5 PM | 8K75F1D | |
| 101C | 959.85 - 960.0 | 10.52 | 1.5 PM | 17K5F1D |
| Power listed is conducted. Device is limited to fixed applications only. The transmitter must be installed to provide a separation distance of at least 152 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
EAS Grant - Application bkC3i/A2KxTZcIxXaKatyQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Sensus Metering Systems Inc. 639 Davis Drive Morrisville, NC 27560 United States |
Date of Grant: 04/12/2013 Application Dated: 04/12/2013 |
| Attention: Richard Daniel , Director, Engineering NPI and Project Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SDBM400V00 |
| Name of Grantee: | Sensus Metering Systems Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Base Station Transceiver |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 930.0 - 931.0 | 10.52 | 1.0 PM | 5K90F1D | |
| 24D | 930.0 - 931.0 | 10.52 | 1.0 PM | 11K8F1D | |
| 24D | 930.0 - 931.0 | 10.52 | 1.0 PM | 8K75F1D | |
| 24D | 930.0 - 931.0 | 10.52 | 1.0 PM | 17K5F1D | |
| 24D | 940.0 - 941.0 | 10.52 | 1.0 PM | 5K90F1D | |
| 24D | 940.0 - 941.0 | 10.52 | 1.0 PM | 11K8F1D | |
| 24D | 940.0 - 941.0 | 10.52 | 1.0 PM | 8K75F1D | |
| 24D | 940.0 - 941.0 | 10.52 | 1.0 PM | 17K5F1D | |
| 101C | 941.0 - 941.5 | 10.52 | 1.5 PM | 5K90F1D | |
| 101C | 941.0 - 941.5 | 10.52 | 1.5 PM | 11K8F1D | |
| 101C | 941.0 - 941.5 | 10.52 | 1.5 PM | 8K75F1D | |
| 101C | 941.0 - 941.5 | 10.52 | 1.5 PM | 17K5F1D | |
| 101C | 952.0 - 953.0 | 10.52 | 1.5 PM | 5K90F1D | |
| 101C | 952.0 - 953.0 | 10.52 | 1.5 PM | 11K8F1D | |
| 101C | 952.0 - 953.0 | 10.52 | 1.5 PM | 8K75F1D | |
| 101C | 952.0 - 953.0 | 10.52 | 1.5 PM | 17K5F1D | |
| 101C | 959.85 - 960.0 | 10.52 | 1.5 PM | 5K90F1D | |
| 101C | 959.85 - 960.0 | 10.52 | 1.5 PM | 11K8F1D | |
| 101C | 959.85 - 960.0 | 10.52 | 1.5 PM | 8K75F1D | |
| 101C | 959.85 - 960.0 | 10.52 | 1.5 PM | 17K5F1D |
| Power listed is conducted. Device is limited to fixed applications only. The transmitter must be installed to provide a separation distance of at least 152 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| Mail To: |