FCC ID SDBM420V00

Base Station Transceiver

by Sensus Metering Systems Inc.

Grantee Code: SDB   Product Code: M420V00
Latest application date: 2023-01-06

FCC ID Device Details

FCC IDSDBM420V00
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSDB
Product CodeM420V00
Applicant BusinessSensus Metering Systems Inc. 🇺🇸
Related Domains xylem.com
Equipment ClassBase Station Transceiver
Test FirmTUV SUD America Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
959.85-960 MHzOriginal Equipment2023-01-06

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2023-01-06PDF 176.6 KB
External PhotosExternal Photos2023-01-06PDF 891.7 KB
Label InformationID Label/Location Info2023-01-06PDF 170.7 KB
Test Setup PhotosTest Setup Photos2023-01-06PDF 4 MB
Test ReportTest Report2023-01-06PDF 3.4 MB
Agency Agreement LetterCover Letter(s)2023-01-06PDF 608.8 KB
Confidentiality RequestCover Letter(s)2023-01-06PDF 26 KB
NDA AgreementCover Letter(s)2023-01-06PDF 42.4 KB
RF ExposureRF Exposure Info2023-01-06PDF 48.3 KB
Internal Photos Metadata onlyInternal PhotosPDF 1.8 MB
Block Diagram Metadata onlyBlock DiagramPDF 455.6 KB
Schematics Metadata onlySchematicsPDF 4 MB
Operational Description Metadata onlyOperational DescriptionPDF 2.5 MB
Parts List Metadata onlyParts List/Tune Up InfoPDF 112.9 KB
Tune Up Procedure 1 of 2 Metadata onlyParts List/Tune Up InfoPDF 536.2 KB
Tune Up Procedure 2 of 2 Metadata onlyParts List/Tune Up InfoPDF 478.6 KB

Application Information

Application IDA3BJfTupwg6s7tc47NKZEg==
Final Action Date2023-01-06
Application PurposeOriginal Equipment
Applicant FRN0003180007
ModelM420V00
Frequency Range959.85-960 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionBase Station Transceiver
Responsible PartyRocio Echeverria, VP, Water & Energy Measurement Product Group, rocio.echeverria@xylem.com , 847-983-5508
AgentKirby Kirby Kirby, TUV SUD America
Test FirmWilliam Elliott, TUV SUD America Inc., William.Elliott@tuvsud.com , 813-284-2736
TCB Emailjeff.woods@tuvsud.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. Device is limited to fixed applications only. The transmitter must be installed to provide a separation distance of at least 371cm (with 12.15 dBi antenna) or 931cm (with 20.15 dBi antenna) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
A3BJfTupwg6s7tc47NKZEg==2023-01-06Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
930-931 MHz57.81ppm8K75F1D24D
930-931 MHz57.81ppm17K5F1D24D
940-941 MHz65.91ppm5K90F1D24D
940-941 MHz65.91ppm11K8F1D24D
940-941 MHz65.91ppm8K75F1D24D
940-941 MHz65.91ppm17K5F1D24D
941-941.5 MHz64.11ppm11K8F1D101C
941-941.5 MHz64.11ppm8K75F1D101C
941-941.5 MHz64.11ppm17K5F1D101C
941-941.5 MHz64.11ppm5K90F1D101C
952-953 MHz62.51ppm5K90F1D101C
952-953 MHz62.51ppm11K8F1D101C
952-953 MHz62.51ppm8K75F1D101C
952-953 MHz62.51ppm17K5F1D101C
959.85-960 MHz63.51ppm5K90F1D101C
959.85-960 MHz63.51ppm11K8F1D101C
959.85-960 MHz63.51ppm8K75F1D101C
959.85-960 MHz63.51ppm17K5F1D101C

Grants

TCB Grant - Application A3BJfTupwg6s7tc47NKZEg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD America Inc.
401 Edgewater Place Suite #500
Wakefield, MA 01880
Date of Grant: 01/06/2023

Application Dated: 01/06/2023
Sensus Metering Systems Inc.
637 Davis Drive
Morrisville, NC 27560
 
Attention: Rocio Echeverria , VP, Water & Energy Measurement Product Group

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBM420V00
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Base Station Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 930.0  -  931.0 57.8 1.0  PM 5K90F1D
24D 930.0  -  931.0 57.8 1.0  PM 11K8F1D
24D 930.0  -  931.0 57.8 1.0  PM 8K75F1D
24D 930.0  -  931.0 57.8 1.0  PM 17K5F1D
24D 940.0  -  941.0 65.9 1.0  PM 5K90F1D
24D 940.0  -  941.0 65.9 1.0  PM 11K8F1D
24D 940.0  -  941.0 65.9 1.0  PM 8K75F1D
24D 940.0  -  941.0 65.9 1.0  PM 17K5F1D
101C 941.0  -  941.5 64.1 1.0  PM 5K90F1D
101C 941.0  -  941.5 64.1 1.0  PM 11K8F1D
101C 941.0  -  941.5 64.1 1.0  PM 8K75F1D
101C 941.0  -  941.5 64.1 1.0  PM 17K5F1D
101C 952.0  -  953.0 62.5 1.0  PM 5K90F1D
101C 952.0  -  953.0 62.5 1.0  PM 11K8F1D
101C 952.0  -  953.0 62.5 1.0  PM 8K75F1D
101C 952.0  -  953.0 62.5 1.0  PM 17K5F1D
101C 959.85  -  960.0 63.5 1.0  PM 5K90F1D
101C 959.85  -  960.0 63.5 1.0  PM 11K8F1D
101C 959.85  -  960.0 63.5 1.0  PM 8K75F1D
101C 959.85  -  960.0 63.5 1.0  PM 17K5F1D

Power listed is conducted. Device is limited to fixed applications only. The transmitter must be installed to provide a separation distance of at least 371cm (with 12.15 dBi antenna) or 931cm (with 20.15 dBi antenna) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

EAS Grant - Application A3BJfTupwg6s7tc47NKZEg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensus Metering Systems Inc.
637 Davis Drive
Morrisville, NC 27560
United States
  Date of Grant: 01/06/2023

Application Dated: 01/06/2023
 
Attention: Rocio Echeverria , VP, Water & Energy Measurement Product Group

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBM420V00
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Base Station Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 930.0  -  931.0 57.8 1.0  PM 5K90F1D
24D 930.0  -  931.0 57.8 1.0  PM 11K8F1D
24D 930.0  -  931.0 57.8 1.0  PM 8K75F1D
24D 930.0  -  931.0 57.8 1.0  PM 17K5F1D
24D 940.0  -  941.0 65.9 1.0  PM 5K90F1D
24D 940.0  -  941.0 65.9 1.0  PM 11K8F1D
24D 940.0  -  941.0 65.9 1.0  PM 8K75F1D
24D 940.0  -  941.0 65.9 1.0  PM 17K5F1D
101C 941.0  -  941.5 64.1 1.0  PM 5K90F1D
101C 941.0  -  941.5 64.1 1.0  PM 11K8F1D
101C 941.0  -  941.5 64.1 1.0  PM 8K75F1D
101C 941.0  -  941.5 64.1 1.0  PM 17K5F1D
101C 952.0  -  953.0 62.5 1.0  PM 5K90F1D
101C 952.0  -  953.0 62.5 1.0  PM 11K8F1D
101C 952.0  -  953.0 62.5 1.0  PM 8K75F1D
101C 952.0  -  953.0 62.5 1.0  PM 17K5F1D
101C 959.85  -  960.0 63.5 1.0  PM 5K90F1D
101C 959.85  -  960.0 63.5 1.0  PM 11K8F1D
101C 959.85  -  960.0 63.5 1.0  PM 8K75F1D
101C 959.85  -  960.0 63.5 1.0  PM 17K5F1D

Power listed is conducted. Device is limited to fixed applications only. The transmitter must be installed to provide a separation distance of at least 371cm (with 12.15 dBi antenna) or 931cm (with 20.15 dBi antenna) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.



Mail To: