FCC ID SDBM420V00
Base Station Transceiver
by Sensus Metering Systems Inc.
Grantee Code: SDB Product Code: M420V00
Latest application date: 2023-01-06
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 959.85-960 MHz | Original Equipment | 2023-01-06 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Manual | Users Manual | 2023-01-06 | PDF 176.6 KB |
| External Photos | External Photos | 2023-01-06 | PDF 891.7 KB |
| Label Information | ID Label/Location Info | 2023-01-06 | PDF 170.7 KB |
| Test Setup Photos | Test Setup Photos | 2023-01-06 | PDF 4 MB |
| Test Report | Test Report | 2023-01-06 | PDF 3.4 MB |
| Agency Agreement Letter | Cover Letter(s) | 2023-01-06 | PDF 608.8 KB |
| Confidentiality Request | Cover Letter(s) | 2023-01-06 | PDF 26 KB |
| NDA Agreement | Cover Letter(s) | 2023-01-06 | PDF 42.4 KB |
| RF Exposure | RF Exposure Info | 2023-01-06 | PDF 48.3 KB |
| Internal Photos Metadata only | Internal Photos | PDF 1.8 MB | |
| Block Diagram Metadata only | Block Diagram | PDF 455.6 KB | |
| Schematics Metadata only | Schematics | PDF 4 MB | |
| Operational Description Metadata only | Operational Description | PDF 2.5 MB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 112.9 KB | |
| Tune Up Procedure 1 of 2 Metadata only | Parts List/Tune Up Info | PDF 536.2 KB | |
| Tune Up Procedure 2 of 2 Metadata only | Parts List/Tune Up Info | PDF 478.6 KB |
Application Information
| Application ID | A3BJfTupwg6s7tc47NKZEg== |
|---|---|
| Final Action Date | 2023-01-06 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0003180007 |
| Model | M420V00 |
| Frequency Range | 959.85-960 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Base Station Transceiver |
| Responsible Party | Rocio Echeverria, VP, Water & Energy Measurement Product Group, rocio.echeverria@xylem.com |
| Agent | Kirby Kirby Kirby, TUV SUD America |
| Test Firm | William Elliott, TUV SUD America Inc., William.Elliott@tuvsud.com |
| TCB Email | jeff.woods@tuvsud.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. Device is limited to fixed applications only. The transmitter must be installed to provide a separation distance of at least 371cm (with 12.15 dBi antenna) or 931cm (with 20.15 dBi antenna) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| A3BJfTupwg6s7tc47NKZEg== | 2023-01-06 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 930-931 MHz | 57.8 | 1ppm | 8K75F1D | 24D |
| 930-931 MHz | 57.8 | 1ppm | 17K5F1D | 24D |
| 940-941 MHz | 65.9 | 1ppm | 5K90F1D | 24D |
| 940-941 MHz | 65.9 | 1ppm | 11K8F1D | 24D |
| 940-941 MHz | 65.9 | 1ppm | 8K75F1D | 24D |
| 940-941 MHz | 65.9 | 1ppm | 17K5F1D | 24D |
| 941-941.5 MHz | 64.1 | 1ppm | 11K8F1D | 101C |
| 941-941.5 MHz | 64.1 | 1ppm | 8K75F1D | 101C |
| 941-941.5 MHz | 64.1 | 1ppm | 17K5F1D | 101C |
| 941-941.5 MHz | 64.1 | 1ppm | 5K90F1D | 101C |
| 952-953 MHz | 62.5 | 1ppm | 5K90F1D | 101C |
| 952-953 MHz | 62.5 | 1ppm | 11K8F1D | 101C |
| 952-953 MHz | 62.5 | 1ppm | 8K75F1D | 101C |
| 952-953 MHz | 62.5 | 1ppm | 17K5F1D | 101C |
| 959.85-960 MHz | 63.5 | 1ppm | 5K90F1D | 101C |
| 959.85-960 MHz | 63.5 | 1ppm | 11K8F1D | 101C |
| 959.85-960 MHz | 63.5 | 1ppm | 8K75F1D | 101C |
| 959.85-960 MHz | 63.5 | 1ppm | 17K5F1D | 101C |
Grants
TCB Grant - Application A3BJfTupwg6s7tc47NKZEg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD America Inc. 401 Edgewater Place Suite #500 Wakefield, MA 01880 |
Date of Grant: 01/06/2023 Application Dated: 01/06/2023 |
| Sensus Metering Systems Inc. |
| 637 Davis Drive |
| Morrisville, NC 27560 |
| Attention: Rocio Echeverria , VP, Water & Energy Measurement Product Group |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SDBM420V00 |
| Name of Grantee: | Sensus Metering Systems Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Base Station Transceiver |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 930.0 - 931.0 | 57.8 | 1.0 PM | 5K90F1D | |
| 24D | 930.0 - 931.0 | 57.8 | 1.0 PM | 11K8F1D | |
| 24D | 930.0 - 931.0 | 57.8 | 1.0 PM | 8K75F1D | |
| 24D | 930.0 - 931.0 | 57.8 | 1.0 PM | 17K5F1D | |
| 24D | 940.0 - 941.0 | 65.9 | 1.0 PM | 5K90F1D | |
| 24D | 940.0 - 941.0 | 65.9 | 1.0 PM | 11K8F1D | |
| 24D | 940.0 - 941.0 | 65.9 | 1.0 PM | 8K75F1D | |
| 24D | 940.0 - 941.0 | 65.9 | 1.0 PM | 17K5F1D | |
| 101C | 941.0 - 941.5 | 64.1 | 1.0 PM | 5K90F1D | |
| 101C | 941.0 - 941.5 | 64.1 | 1.0 PM | 11K8F1D | |
| 101C | 941.0 - 941.5 | 64.1 | 1.0 PM | 8K75F1D | |
| 101C | 941.0 - 941.5 | 64.1 | 1.0 PM | 17K5F1D | |
| 101C | 952.0 - 953.0 | 62.5 | 1.0 PM | 5K90F1D | |
| 101C | 952.0 - 953.0 | 62.5 | 1.0 PM | 11K8F1D | |
| 101C | 952.0 - 953.0 | 62.5 | 1.0 PM | 8K75F1D | |
| 101C | 952.0 - 953.0 | 62.5 | 1.0 PM | 17K5F1D | |
| 101C | 959.85 - 960.0 | 63.5 | 1.0 PM | 5K90F1D | |
| 101C | 959.85 - 960.0 | 63.5 | 1.0 PM | 11K8F1D | |
| 101C | 959.85 - 960.0 | 63.5 | 1.0 PM | 8K75F1D | |
| 101C | 959.85 - 960.0 | 63.5 | 1.0 PM | 17K5F1D |
| Power listed is conducted. Device is limited to fixed applications only. The transmitter must be installed to provide a separation distance of at least 371cm (with 12.15 dBi antenna) or 931cm (with 20.15 dBi antenna) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
EAS Grant - Application A3BJfTupwg6s7tc47NKZEg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Sensus Metering Systems Inc. 637 Davis Drive Morrisville, NC 27560 United States |
Date of Grant: 01/06/2023 Application Dated: 01/06/2023 |
| Attention: Rocio Echeverria , VP, Water & Energy Measurement Product Group |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SDBM420V00 |
| Name of Grantee: | Sensus Metering Systems Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Base Station Transceiver |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 930.0 - 931.0 | 57.8 | 1.0 PM | 5K90F1D | |
| 24D | 930.0 - 931.0 | 57.8 | 1.0 PM | 11K8F1D | |
| 24D | 930.0 - 931.0 | 57.8 | 1.0 PM | 8K75F1D | |
| 24D | 930.0 - 931.0 | 57.8 | 1.0 PM | 17K5F1D | |
| 24D | 940.0 - 941.0 | 65.9 | 1.0 PM | 5K90F1D | |
| 24D | 940.0 - 941.0 | 65.9 | 1.0 PM | 11K8F1D | |
| 24D | 940.0 - 941.0 | 65.9 | 1.0 PM | 8K75F1D | |
| 24D | 940.0 - 941.0 | 65.9 | 1.0 PM | 17K5F1D | |
| 101C | 941.0 - 941.5 | 64.1 | 1.0 PM | 5K90F1D | |
| 101C | 941.0 - 941.5 | 64.1 | 1.0 PM | 11K8F1D | |
| 101C | 941.0 - 941.5 | 64.1 | 1.0 PM | 8K75F1D | |
| 101C | 941.0 - 941.5 | 64.1 | 1.0 PM | 17K5F1D | |
| 101C | 952.0 - 953.0 | 62.5 | 1.0 PM | 5K90F1D | |
| 101C | 952.0 - 953.0 | 62.5 | 1.0 PM | 11K8F1D | |
| 101C | 952.0 - 953.0 | 62.5 | 1.0 PM | 8K75F1D | |
| 101C | 952.0 - 953.0 | 62.5 | 1.0 PM | 17K5F1D | |
| 101C | 959.85 - 960.0 | 63.5 | 1.0 PM | 5K90F1D | |
| 101C | 959.85 - 960.0 | 63.5 | 1.0 PM | 11K8F1D | |
| 101C | 959.85 - 960.0 | 63.5 | 1.0 PM | 8K75F1D | |
| 101C | 959.85 - 960.0 | 63.5 | 1.0 PM | 17K5F1D |
| Power listed is conducted. Device is limited to fixed applications only. The transmitter must be installed to provide a separation distance of at least 371cm (with 12.15 dBi antenna) or 931cm (with 20.15 dBi antenna) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| Mail To: |