FCC ID SDBTXCVRBB01
GENERIC TRANSCEIVER MODULE
by Sensus Metering Systems Inc.
Grantee Code: SDB Product Code: TXCVRBB01
Latest application date: 2009-09-17
FCC ID Device Details
| FCC ID | SDBTXCVRBB01 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | SDB |
| Product Code | TXCVRBB01 |
| Applicant Business | Sensus Metering Systems Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | GENERIC TRANSCEIVER MODULE |
| Test Firm | Advanced Compliance Solutions, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 896.038-901 MHz | Class II permissive change or modification of presently authorized equipment | 2009-09-17 |
| 896.038-901 MHz | Class II permissive change or modification of presently authorized equipment | 2008-04-09 |
| 896.038-901 MHz | Original Equipment | 2007-07-13 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos | External Photos | 2009-09-17 | PDF 1.2 MB |
| EXTERNAL PHOTOS | External Photos | 2007-07-13 | PDF 17.1 KB |
| LABEL INFORMATION | ID Label/Location Info | 2007-07-13 | PDF 52.8 KB |
| TEST SETUP PHOTOS | Test Setup Photos | 2008-04-09 | PDF 635.9 KB |
| TEST SETUP PHOTOS | Test Report | 2007-07-13 | PDF 658 KB |
| TEST REPORT | Test Report | 2008-04-09 | PDF 79.4 KB |
| TEST REPORT LD | Test Report | 2007-07-13 | PDF 813.9 KB |
| Agency Agreement | Cover Letter(s) | 2009-09-17 | PDF 59.7 KB |
| FCC Confidentiality Request | Cover Letter(s) | 2009-09-17 | PDF 18 KB |
| FCC Cover Letter | Cover Letter(s) | 2009-09-17 | PDF 17.3 KB |
| AGENCY AGREEMENT | Cover Letter(s) | 2008-04-09 | PDF 248.3 KB |
| CONFIDENTIAL LETTER | Cover Letter(s) | 2008-04-09 | PDF 26.8 KB |
| COVER LETTER | Cover Letter(s) | 2008-04-09 | PDF 19.3 KB |
| AGENCY AGREEMENT | Cover Letter(s) | 2007-07-13 | PDF 24 KB |
| CONFIDNETIALITY | Cover Letter(s) | 2007-07-13 | PDF 31.5 KB |
| RF Exposure | RF Exposure Info | 2009-09-17 | PDF 29.4 KB |
| RF EXPOSURE | RF Exposure Info | 2007-07-13 | PDF 32.6 KB |
Application Information
| Application ID | 2yIws6kcLJ2yOwRNnnsTSQ== |
|---|---|
| Final Action Date | 2009-09-17 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0003180007 |
| Model | TXCVRBB01 |
| Frequency Range | 896.038-901 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | GENERIC TRANSCEIVER MODULE |
| Responsible Party | Richard Daniel, Director, Engineering NPI and Project Management, Richard.Daniel@sensus.com |
| Agent | Sam Sam Sam, Advanced Compliance Solutions, Inc., swismer@acstestlab.com |
| Test Firm | Sam Wismer, Advanced Compliance Solutions, Inc., swismer@acstestlab.com |
| TCB Email | jwoods@acstestlab.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Single Modular Approval |
| Composite Device | No |
| Composite Part | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). Class II Change to address co-location in a Sensus FlexNet Remote Portal (FRP) host device with either FCC ID: AU792U04A22760 or FCC ID: O9EQ2687 in a fixed operating environment. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 2yIws6kcLJ2yOwRNnnsTSQ== | 2009-09-17 | Class II permissive change or modification of presently authorized equipment |
| CwrfhORaBN6Jofb7K79D1A== | 2008-04-09 | Class II permissive change or modification of presently authorized equipment |
| jgozDcQ2GUVCfpCp15dfvw== | 2007-07-13 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 896.038-901 MHz | 1 | 1.5ppm | 9K60F2D | 9 |
| 896.038-901 MHz | 1 | 1.5ppm | 1K10F2D | 9 |
| 896.038-901 MHz | 1 | 1.5ppm | 4K80F2D | 9 |
| 901-902 MHz | 1 | 1ppm | 1K10F2D | 24D |
| 901-902 MHz | 1 | 1ppm | 4K80F2D | 24D |
| 928.85-929 MHz | 1 | 1.5ppm | 9K60F2D | 101C |
| 928.85-929 MHz | 1 | 1.5ppm | 1K10F2D | 101C |
| 928.85-929 MHz | 1 | 1.5ppm | 4K80F2D | 101C |
| 930-931 MHz | 1 | 1ppm | 5K90F1D | 24D |
| 932-932.5 MHz | 1 | 1.5ppm | 9K60F2D | 101C |
| 932-932.5 MHz | 1 | 1.5ppm | 1K10F2D | 101C |
| 932-932.5 MHz | 1 | 1.5ppm | 4K80F2D | 101C |
| 935-940 MHz | 1 | 1.5ppm | 5K90F1D | 9 |
| 940-941 MHz | 1 | 1ppm | 5K90F1D | 24D |
| 941-941.5 MHz | 1 | 1.5ppm | 5K90F1D | 101C |
| 959.85-960 MHz | 1 | 1.5ppm | 5K90F1D | 101C |
Grants
TCB Grant - Application jgozDcQ2GUVCfpCp15dfvw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| Timco Engineering, Inc. 849 NW State Road 45 <BR>P.O. Box 370, Newberry, FL 32669 | Date of Grant: 07/13/2007 Application Dated: 07/12/2007 |
| Sensus Metering Systems Inc. |
| 639 Davis Drive |
| Morrisville, NC 27560 |
| Attention: Richard Daniel , Director, Engineering NPI and Project Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SDBTXCVRBB01 |
| Name of Grantee: | Sensus Metering Systems Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | GENERIC TRANSCEIVER MODULE |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 9K60F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 1K10F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 4K80F2D | |
| 24D | 930.0 - 931.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 24D | 940.0 - 941.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 90 | 935.0 - 940.0 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 941.0 - 941.5 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 959.85 - 960.0 | 1.0 | 1.5 PM | 5K90F1D |
| Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
EAS Grant - Application jgozDcQ2GUVCfpCp15dfvw==
| COPY |
FEDERAL COMMUNICATIONS
COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Sensus Metering Systems Inc.
639 Davis Drive Morrisville, NC 27560 United States |
Date of Grant: 07/13/2007
Application Dated: 07/12/2007 |
| Attention: Richard Daniel , Director, Engineering NPI and Project Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SDBTXCVRBB01 |
| Name of Grantee: | Sensus Metering Systems Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | GENERIC TRANSCEIVER MODULE |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts |
Frequency
Range (MHZ) |
Output
Watts |
Frequency
Tolerance |
Emission
Designator |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 9K60F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 1K10F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 4K80F2D | |
| 24D | 930.0 - 931.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 24D | 940.0 - 941.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 90 | 935.0 - 940.0 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 941.0 - 941.5 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 959.85 - 960.0 | 1.0 | 1.5 PM | 5K90F1D |
|
Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of 2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).
|
| Mail To: |
|
EA769670 |
TCB Grant - Application CwrfhORaBN6Jofb7K79D1A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 <BR>P.O. Box 370, Newberry, FL 32669 |
Date of Grant: 04/09/2008 Application Dated: 04/08/2008 |
| Sensus Metering Systems Inc. |
| 639 Davis Drive |
| Morrisville, NC 27560 |
| Attention: Richard Daniel , Director, Engineering NPI and Project Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SDBTXCVRBB01 |
| Name of Grantee: | Sensus Metering Systems Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | GENERIC TRANSCEIVER MODULE |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 9K60F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 1K10F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 4K80F2D | |
| 24D | 930.0 - 931.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 24D | 940.0 - 941.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 90 | 935.0 - 940.0 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 941.0 - 941.5 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 959.85 - 960.0 | 1.0 | 1.5 PM | 5K90F1D |
| Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).
|
EAS Grant - Application CwrfhORaBN6Jofb7K79D1A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Sensus Metering Systems Inc. 639 Davis Drive Morrisville, NC 27560 United States |
Date of Grant: 04/09/2008 Application Dated: 04/08/2008 |
| Attention: Richard Daniel , Director, Engineering NPI and Project Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SDBTXCVRBB01 |
| Name of Grantee: | Sensus Metering Systems Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | GENERIC TRANSCEIVER MODULE |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 9K60F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 1K10F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 4K80F2D | |
| 24D | 930.0 - 931.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 24D | 940.0 - 941.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 90 | 935.0 - 940.0 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 941.0 - 941.5 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 959.85 - 960.0 | 1.0 | 1.5 PM | 5K90F1D |
| Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).
|
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Advanced Compliance Solutions, Inc. 5015 B.U. Bowman Drive Buford, GA 30518 |
Date of Grant: 09/17/2009 Application Dated: 09/10/2009 |
| Sensus Metering Systems Inc. |
| 639 Davis Drive |
| Morrisville, NC 27560 |
| Attention: Richard Daniel , Director, Engineering NPI and Project Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SDBTXCVRBB01 |
| Name of Grantee: | Sensus Metering Systems Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | GENERIC TRANSCEIVER MODULE |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 9K60F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 1K10F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 4K80F2D | |
| 24D | 930.0 - 931.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 24D | 940.0 - 941.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 90 | 935.0 - 940.0 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 941.0 - 941.5 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 959.85 - 960.0 | 1.0 | 1.5 PM | 5K90F1D |
| Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). Class II Change to address co-location in a Sensus FlexNet Remote Portal (FRP) host device with either FCC ID: AU792U04A22760 or FCC ID: O9EQ2687 in a fixed operating environment. |
EAS Grant - Application 2yIws6kcLJ2yOwRNnnsTSQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Sensus Metering Systems Inc. 639 Davis Drive Morrisville, NC 27560 United States |
Date of Grant: 09/17/2009 Application Dated: 09/10/2009 |
| Attention: Richard Daniel , Director, Engineering NPI and Project Management |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SDBTXCVRBB01 |
| Name of Grantee: | Sensus Metering Systems Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | GENERIC TRANSCEIVER MODULE |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 9K60F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 1K10F2D | |
| 24D | 901.0 - 902.0 | 1.0 | 1.0 PM | 4K80F2D | |
| 24D | 930.0 - 931.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 24D | 940.0 - 941.0 | 1.0 | 1.0 PM | 5K90F1D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 90 | 896.0375 - 901.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 90 | 935.0 - 940.0 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 928.85 - 929.0 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 9K60F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 1K10F2D | |
| 101C | 932.0 - 932.5 | 1.0 | 1.5 PM | 4K80F2D | |
| 101C | 941.0 - 941.5 | 1.0 | 1.5 PM | 5K90F1D | |
| 101C | 959.85 - 960.0 | 1.0 | 1.5 PM | 5K90F1D |
| Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). Class II Change to address co-location in a Sensus FlexNet Remote Portal (FRP) host device with either FCC ID: AU792U04A22760 or FCC ID: O9EQ2687 in a fixed operating environment. |
| Mail To: |