FCC ID SDBTXCVRBB01

GENERIC TRANSCEIVER MODULE

by Sensus Metering Systems Inc.

Grantee Code: SDB   Product Code: TXCVRBB01
Latest application date: 2009-09-17

FCC ID Device Details

FCC IDSDBTXCVRBB01
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSDB
Product CodeTXCVRBB01
Applicant BusinessSensus Metering Systems Inc. 🇺🇸
Related Domains sensus.com
Equipment ClassGENERIC TRANSCEIVER MODULE
Test FirmAdvanced Compliance Solutions, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
896.038-901 MHzClass II permissive change or modification of presently authorized equipment2009-09-17
896.038-901 MHzClass II permissive change or modification of presently authorized equipment2008-04-09
896.038-901 MHzOriginal Equipment2007-07-13

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2009-09-17PDF 1.2 MB
EXTERNAL PHOTOSExternal Photos2007-07-13PDF 17.1 KB
LABEL INFORMATIONID Label/Location Info2007-07-13PDF 52.8 KB
TEST SETUP PHOTOSTest Setup Photos2008-04-09PDF 635.9 KB
TEST SETUP PHOTOSTest Report2007-07-13PDF 658 KB
TEST REPORTTest Report2008-04-09PDF 79.4 KB
TEST REPORT LDTest Report2007-07-13PDF 813.9 KB
Agency AgreementCover Letter(s)2009-09-17PDF 59.7 KB
FCC Confidentiality RequestCover Letter(s)2009-09-17PDF 18 KB
FCC Cover LetterCover Letter(s)2009-09-17PDF 17.3 KB
AGENCY AGREEMENTCover Letter(s)2008-04-09PDF 248.3 KB
CONFIDENTIAL LETTERCover Letter(s)2008-04-09PDF 26.8 KB
COVER LETTERCover Letter(s)2008-04-09PDF 19.3 KB
AGENCY AGREEMENTCover Letter(s)2007-07-13PDF 24 KB
CONFIDNETIALITYCover Letter(s)2007-07-13PDF 31.5 KB
RF ExposureRF Exposure Info2009-09-17PDF 29.4 KB
RF EXPOSURERF Exposure Info2007-07-13PDF 32.6 KB

Application Information

Application ID2yIws6kcLJ2yOwRNnnsTSQ==
Final Action Date2009-09-17
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0003180007
ModelTXCVRBB01
Frequency Range896.038-901 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionGENERIC TRANSCEIVER MODULE
Responsible PartyRichard Daniel, Director, Engineering NPI and Project Management, Richard.Daniel@sensus.com , 919-424-8912
AgentSam Sam Sam, Advanced Compliance Solutions, Inc., swismer@acstestlab.com , 770 831 8048
Test FirmSam Wismer, Advanced Compliance Solutions, Inc., swismer@acstestlab.com , 770-831-8048
TCB Emailjwoods@acstestlab.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceNo
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsModular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). Class II Change to address co-location in a Sensus FlexNet Remote Portal (FRP) host device with either FCC ID: AU792U04A22760 or FCC ID: O9EQ2687 in a fixed operating environment.

Applications

Application IDDatePurpose
2yIws6kcLJ2yOwRNnnsTSQ==2009-09-17Class II permissive change or modification of presently authorized equipment
CwrfhORaBN6Jofb7K79D1A==2008-04-09Class II permissive change or modification of presently authorized equipment
jgozDcQ2GUVCfpCp15dfvw==2007-07-13Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
896.038-901 MHz11.5ppm9K60F2D9
896.038-901 MHz11.5ppm1K10F2D9
896.038-901 MHz11.5ppm4K80F2D9
901-902 MHz11ppm1K10F2D24D
901-902 MHz11ppm4K80F2D24D
928.85-929 MHz11.5ppm9K60F2D101C
928.85-929 MHz11.5ppm1K10F2D101C
928.85-929 MHz11.5ppm4K80F2D101C
930-931 MHz11ppm5K90F1D24D
932-932.5 MHz11.5ppm9K60F2D101C
932-932.5 MHz11.5ppm1K10F2D101C
932-932.5 MHz11.5ppm4K80F2D101C
935-940 MHz11.5ppm5K90F1D9
940-941 MHz11ppm5K90F1D24D
941-941.5 MHz11.5ppm5K90F1D101C
959.85-960 MHz11.5ppm5K90F1D101C

Grants

TCB Grant - Application jgozDcQ2GUVCfpCp15dfvw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 07/13/2007

Application Dated: 07/12/2007
Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
 
Attention: Richard Daniel , Director, Engineering NPI and Project Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBTXCVRBB01
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: GENERIC TRANSCEIVER MODULE
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 1.0 1.0  PM 9K60F2D
24D 901.0  -  902.0 1.0 1.0  PM 1K10F2D
24D 901.0  -  902.0 1.0 1.0  PM 4K80F2D
24D 930.0  -  931.0 1.0 1.0  PM 5K90F1D
24D 940.0  -  941.0 1.0 1.0  PM 5K90F1D
90 896.0375  -  901.0 1.0 1.5  PM 9K60F2D
90 896.0375  -  901.0 1.0 1.5  PM 1K10F2D
90 896.0375  -  901.0 1.0 1.5  PM 4K80F2D
90 935.0  -  940.0 1.0 1.5  PM 5K90F1D
101C 928.85  -  929.0 1.0 1.5  PM 9K60F2D
101C 928.85  -  929.0 1.0 1.5  PM 1K10F2D
101C 928.85  -  929.0 1.0 1.5  PM 4K80F2D
101C 932.0  -  932.5 1.0 1.5  PM 9K60F2D
101C 932.0  -  932.5 1.0 1.5  PM 1K10F2D
101C 932.0  -  932.5 1.0 1.5  PM 4K80F2D
101C 941.0  -  941.5 1.0 1.5  PM 5K90F1D
101C 959.85  -  960.0 1.0 1.5  PM 5K90F1D

Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.

For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).


EAS Grant - Application jgozDcQ2GUVCfpCp15dfvw==

TYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
United States
  Date of Grant: 07/13/2007

Application Dated: 07/12/2007
 
Attention: Richard Daniel , Director, Engineering NPI and Project Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBTXCVRBB01
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: GENERIC TRANSCEIVER MODULE
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 1.0 1.0  PM 9K60F2D
24D 901.0  -  902.0 1.0 1.0  PM 1K10F2D
24D 901.0  -  902.0 1.0 1.0  PM 4K80F2D
24D 930.0  -  931.0 1.0 1.0  PM 5K90F1D
24D 940.0  -  941.0 1.0 1.0  PM 5K90F1D
90 896.0375  -  901.0 1.0 1.5  PM 9K60F2D
90 896.0375  -  901.0 1.0 1.5  PM 1K10F2D
90 896.0375  -  901.0 1.0 1.5  PM 4K80F2D
90 935.0  -  940.0 1.0 1.5  PM 5K90F1D
101C 928.85  -  929.0 1.0 1.5  PM 9K60F2D
101C 928.85  -  929.0 1.0 1.5  PM 1K10F2D
101C 928.85  -  929.0 1.0 1.5  PM 4K80F2D
101C 932.0  -  932.5 1.0 1.5  PM 9K60F2D
101C 932.0  -  932.5 1.0 1.5  PM 1K10F2D
101C 932.0  -  932.5 1.0 1.5  PM 4K80F2D
101C 941.0  -  941.5 1.0 1.5  PM 5K90F1D
101C 959.85  -  960.0 1.0 1.5  PM 5K90F1D

Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of 2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.

For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).



Mail To:


EA769670

TCB Grant - Application CwrfhORaBN6Jofb7K79D1A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 04/09/2008

Application Dated: 04/08/2008
Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
 
Attention: Richard Daniel , Director, Engineering NPI and Project Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBTXCVRBB01
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: GENERIC TRANSCEIVER MODULE
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 1.0 1.0  PM 9K60F2D
24D 901.0  -  902.0 1.0 1.0  PM 1K10F2D
24D 901.0  -  902.0 1.0 1.0  PM 4K80F2D
24D 930.0  -  931.0 1.0 1.0  PM 5K90F1D
24D 940.0  -  941.0 1.0 1.0  PM 5K90F1D
90 896.0375  -  901.0 1.0 1.5  PM 9K60F2D
90 896.0375  -  901.0 1.0 1.5  PM 1K10F2D
90 896.0375  -  901.0 1.0 1.5  PM 4K80F2D
90 935.0  -  940.0 1.0 1.5  PM 5K90F1D
101C 928.85  -  929.0 1.0 1.5  PM 9K60F2D
101C 928.85  -  929.0 1.0 1.5  PM 1K10F2D
101C 928.85  -  929.0 1.0 1.5  PM 4K80F2D
101C 932.0  -  932.5 1.0 1.5  PM 9K60F2D
101C 932.0  -  932.5 1.0 1.5  PM 1K10F2D
101C 932.0  -  932.5 1.0 1.5  PM 4K80F2D
101C 941.0  -  941.5 1.0 1.5  PM 5K90F1D
101C 959.85  -  960.0 1.0 1.5  PM 5K90F1D

Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).


EAS Grant - Application CwrfhORaBN6Jofb7K79D1A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
United States
  Date of Grant: 04/09/2008

Application Dated: 04/08/2008
 
Attention: Richard Daniel , Director, Engineering NPI and Project Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBTXCVRBB01
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: GENERIC TRANSCEIVER MODULE
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 1.0 1.0  PM 9K60F2D
24D 901.0  -  902.0 1.0 1.0  PM 1K10F2D
24D 901.0  -  902.0 1.0 1.0  PM 4K80F2D
24D 930.0  -  931.0 1.0 1.0  PM 5K90F1D
24D 940.0  -  941.0 1.0 1.0  PM 5K90F1D
90 896.0375  -  901.0 1.0 1.5  PM 9K60F2D
90 896.0375  -  901.0 1.0 1.5  PM 1K10F2D
90 896.0375  -  901.0 1.0 1.5  PM 4K80F2D
90 935.0  -  940.0 1.0 1.5  PM 5K90F1D
101C 928.85  -  929.0 1.0 1.5  PM 9K60F2D
101C 928.85  -  929.0 1.0 1.5  PM 1K10F2D
101C 928.85  -  929.0 1.0 1.5  PM 4K80F2D
101C 932.0  -  932.5 1.0 1.5  PM 9K60F2D
101C 932.0  -  932.5 1.0 1.5  PM 1K10F2D
101C 932.0  -  932.5 1.0 1.5  PM 4K80F2D
101C 941.0  -  941.5 1.0 1.5  PM 5K90F1D
101C 959.85  -  960.0 1.0 1.5  PM 5K90F1D

Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).



TCB Grant - Application 2yIws6kcLJ2yOwRNnnsTSQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 09/17/2009

Application Dated: 09/10/2009
Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
 
Attention: Richard Daniel , Director, Engineering NPI and Project Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBTXCVRBB01
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: GENERIC TRANSCEIVER MODULE
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 1.0 1.0  PM 9K60F2D
24D 901.0  -  902.0 1.0 1.0  PM 1K10F2D
24D 901.0  -  902.0 1.0 1.0  PM 4K80F2D
24D 930.0  -  931.0 1.0 1.0  PM 5K90F1D
24D 940.0  -  941.0 1.0 1.0  PM 5K90F1D
90 896.0375  -  901.0 1.0 1.5  PM 9K60F2D
90 896.0375  -  901.0 1.0 1.5  PM 1K10F2D
90 896.0375  -  901.0 1.0 1.5  PM 4K80F2D
90 935.0  -  940.0 1.0 1.5  PM 5K90F1D
101C 928.85  -  929.0 1.0 1.5  PM 9K60F2D
101C 928.85  -  929.0 1.0 1.5  PM 1K10F2D
101C 928.85  -  929.0 1.0 1.5  PM 4K80F2D
101C 932.0  -  932.5 1.0 1.5  PM 9K60F2D
101C 932.0  -  932.5 1.0 1.5  PM 1K10F2D
101C 932.0  -  932.5 1.0 1.5  PM 4K80F2D
101C 941.0  -  941.5 1.0 1.5  PM 5K90F1D
101C 959.85  -  960.0 1.0 1.5  PM 5K90F1D

Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.

For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Class II Change to address co-location in a Sensus FlexNet Remote Portal (FRP) host device with either FCC ID: AU792U04A22760 or FCC ID: O9EQ2687 in a fixed operating environment.


EAS Grant - Application 2yIws6kcLJ2yOwRNnnsTSQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensus Metering Systems Inc.
639 Davis Drive
Morrisville, NC 27560
United States
  Date of Grant: 09/17/2009

Application Dated: 09/10/2009
 
Attention: Richard Daniel , Director, Engineering NPI and Project Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBTXCVRBB01
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: GENERIC TRANSCEIVER MODULE
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 1.0 1.0  PM 9K60F2D
24D 901.0  -  902.0 1.0 1.0  PM 1K10F2D
24D 901.0  -  902.0 1.0 1.0  PM 4K80F2D
24D 930.0  -  931.0 1.0 1.0  PM 5K90F1D
24D 940.0  -  941.0 1.0 1.0  PM 5K90F1D
90 896.0375  -  901.0 1.0 1.5  PM 9K60F2D
90 896.0375  -  901.0 1.0 1.5  PM 1K10F2D
90 896.0375  -  901.0 1.0 1.5  PM 4K80F2D
90 935.0  -  940.0 1.0 1.5  PM 5K90F1D
101C 928.85  -  929.0 1.0 1.5  PM 9K60F2D
101C 928.85  -  929.0 1.0 1.5  PM 1K10F2D
101C 928.85  -  929.0 1.0 1.5  PM 4K80F2D
101C 932.0  -  932.5 1.0 1.5  PM 9K60F2D
101C 932.0  -  932.5 1.0 1.5  PM 1K10F2D
101C 932.0  -  932.5 1.0 1.5  PM 4K80F2D
101C 941.0  -  941.5 1.0 1.5  PM 5K90F1D
101C 959.85  -  960.0 1.0 1.5  PM 5K90F1D

Modular Approval. Power listed is conducted. This Modular Approval is limited to OEM installation for mobile and fixed applications only. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

For use in RF exposure mobile conditions: The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.

For use in RF exposure fixed conditions: The antenna(s) used for this transmitter must not exceed 11dBi and must be fixed-mounted on outdoor permanent structures providing a separation distance of at least 43 cm from all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Class II Change to address co-location in a Sensus FlexNet Remote Portal (FRP) host device with either FCC ID: AU792U04A22760 or FCC ID: O9EQ2687 in a fixed operating environment.



Mail To: