FCC ID SDBWFL3

Remote Telemetry Module

by Sensus Metering Systems Inc.

Grantee Code: SDB   Product Code: WFL3
Latest application date: 2026-03-04

FCC ID Device Details

FCC IDSDBWFL3
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSDB
Product CodeWFL3
Applicant BusinessSensus Metering Systems Inc. 🇺🇸
Related Domains xylem.com
Equipment ClassRemote Telemetry Module
Test FirmIntertek Testing Services NA Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.75-914.75 MHzOriginal Equipment2026-03-04
959.85-960 MHzOriginal Equipment2026-03-04

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2026-03-04PDF 1.1 MB
External PhotosExternal Photos2026-03-04PDF 263.4 KB
Label InformationID Label/Location Info2026-03-04PDF 138.1 KB
Test Setup PhotosTest Setup Photos2026-03-04PDF 910.6 KB
Antenna InformationTest Report2026-03-04PDF 1.3 MB
Test ReportTest Report2026-03-04PDF 1.2 MB
Test Report 1 of 2Test Report2026-03-04PDF 3.9 MB
Test Report 2 of 2Test Report2026-03-04PDF 3.9 MB
2.911(d)(5)(i)-(ii) Covered EquipmentAttestation Statements2026-03-04PDF 197.7 KB
2.911(d)(7) Agent of ServiceAttestation Statements2026-03-04PDF 244.7 KB
Agency AgreementCover Letter(s)2026-03-04PDF 317 KB
Confidentiality RequestCover Letter(s)2026-03-04PDF 302 KB
FCC Cover LetterCover Letter(s)2026-03-04PDF 108.8 KB
NDA AgreementCover Letter(s)2026-03-04PDF 42.4 KB
RF ExposureRF Exposure Info2026-03-04PDF 518.1 KB
Internal Photos Metadata onlyInternal PhotosPDF 258.2 KB
Block Diagram Metadata onlyBlock DiagramPDF 428 KB
Schematics 3Wire Metadata onlySchematicsPDF 2.8 MB
Schematics TouchCouple Metadata onlySchematicsPDF 2.8 MB
Operational Description Metadata onlyOperational DescriptionPDF 1.5 MB
Parts List 3Wire Metadata onlyParts List/Tune Up InfoPDF 36.1 KB
Parts List TouchCouple Metadata onlyParts List/Tune Up InfoPDF 36.9 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 3.4 MB

Application Information

Application IDh8yZNwwKyZnud1KcM651lQ==
Final Action Date2026-03-04
Application PurposeOriginal Equipment
Applicant FRN0003180007
ModelWFL3
Frequency Range902.75-914.75 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionRemote Telemetry Module
Responsible PartyRay Britt, ray.britt@xylem.com , 919-665-7878
Non-Technical ContactRay Britt, Sensus a Xylem Brand, ray.britt@xylem.com , 9196657878
Test FirmJeff Hiday, Intertek Testing Services NA Inc., jeff.hiday@intertek.com , 678-775-2415
TCB Emailjeff.woods@tuvsud.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
h8yZNwwKyZnud1KcM651lQ==2026-03-04Original Equipment
eX1HAqeQOMMdcUAxTGaXyA==2026-03-04Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
902.75-914.75 MHz0.08415C
901-902 MHz0.9591.0 PM9K60F2D24D
901-902 MHz9.9591.0 PM4K80F2D24D
901-902 MHz0.9591.0 PM1K10F2D24D
901-902 MHz0.9591.0 PM5K00F1D24D
901-902 MHz0.9591.0 PM5K60F1D24D
901-902 MHz0.9591.0 PM5K90F1D24D
901-902 MHz0.9591.0 PM10K0F1D24D
901-902 MHz0.9591.0 PM11K3F1D24D
901-902 MHz0.9591.0 PM11K9F1D24D
901-902 MHz0.9591.0 PM1K30F1D24D
930-931 MHz0.9621.0 PM5K90F1D24D
930-931 MHz0.9621.0 PM11K8F1D24D
940-941 MHz0.9421.0 PM5K90F1D24D
940-941 MHz0.9421.0 PM11K8F1D24D
928.85-929 MHz0.9641.0 PM9K60F2D101C
928.85-929 MHz0.9641.0 PM4K80F2D101C
928.85-929 MHz0.9641.0 PM1K10F2D101C
928.85-929 MHz0.9641.0 PM5K00F1D101C
928.85-929 MHz0.9641.0 PM5K60F1D101C
928.85-929 MHz0.9641.0 PM5K90F1D101C
928.85-929 MHz0.9641.0 PM10K0F1D101C
928.85-929 MHz0.9641.0 PM11K3F1D101C
928.85-929 MHz0.9641.0 PM11K9F1D101C
928.85-929 MHz0.9641.0 PM1K30F1D101C
932-932.5 MHz0.9621.0 PM9K60F2D101C
932-932.5 MHz0.9621.0 PM4K80F2D101C
932-932.5 MHz0.9621.0 PM1K10F2D101C
932-932.5 MHz0.9621.0 PM5K00F1D101C
932-932.5 MHz0.9621.0 PM5K60F1D101C
932-932.5 MHz0.9621.0 PM5K90F1D101C
932-932.5 MHz0.9621.0 PM10K0F1D101C
932-932.5 MHz0.9621.0 PM11K3F1D101C
932-932.5 MHz0.9621.0 PM11K9F1D101C
932-932.5 MHz0.9621.0 PM1K30F1D101C
941-941.5 MHz0.9351.0 PM5K90F1D101C
941-941.5 MHz0.9351.0 PM11K8F1D101C
952-953 MHz0.9161.0 PM5K90F1D101C
952-953 MHz0.9161.0 PM11K8F1D101C
959.85-960 MHz0.9061.0 PM5K90F1D101C
959.85-960 MHz0.9061.0 PM11K8F1D101C

Grants

TCB Grant - Application h8yZNwwKyZnud1KcM651lQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD America Inc.
401 Edgewater Place Suite #500
Wakefield, MA 01880
Date of Grant: 03/04/2026

Application Dated: 03/02/2026
Sensus Metering Systems Inc.
637 Davis Drive
Morrisville, NC 27560
 
Attention: Ray Britt , Senior Director, Global System Test

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBWFL3
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: Digital Transmission System
Notes: Remote Telemetry Module
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.75  -  914.75 0.084  

Power listed is average conducted. This grant is valid only when the device is installed by the grantee or contractors employed by the grantee who are instructed to ensure that the end-user has no manual instructions to remove or install the device. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Co-located with FCC ID: SDBSNUSCM1.

TCB Grant - Application eX1HAqeQOMMdcUAxTGaXyA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD America Inc.
401 Edgewater Place Suite #500
Wakefield, MA 01880
Date of Grant: 03/04/2026

Application Dated: 03/02/2026
Sensus Metering Systems Inc.
637 Davis Drive
Morrisville, NC 27560
 
Attention: Ray Britt , Senior Director, Global System Test

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SDBWFL3
Name of Grantee:  Sensus Metering Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Remote Telemetry Module
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24D 901.0  -  902.0 0.959 1.0  PM 9K60F2D
24D 901.0  -  902.0 9.959 1.0  PM 4K80F2D
24D 901.0  -  902.0 0.959 1.0  PM 1K10F2D
24D 901.0  -  902.0 0.959 1.0  PM 5K00F1D
24D 901.0  -  902.0 0.959 1.0  PM 5K60F1D
24D 901.0  -  902.0 0.959 1.0  PM 5K90F1D
24D 901.0  -  902.0 0.959 1.0  PM 10K0F1D
24D 901.0  -  902.0 0.959 1.0  PM 11K3F1D
24D 901.0  -  902.0 0.959 1.0  PM 11K9F1D
24D 901.0  -  902.0 0.959 1.0  PM 1K30F1D
24D 930.0  -  931.0 0.962 1.0  PM 5K90F1D
24D 930.0  -  931.0 0.962 1.0  PM 11K8F1D
24D 940.0  -  941.0 0.942 1.0  PM 5K90F1D
24D 940.0  -  941.0 0.942 1.0  PM 11K8F1D
101C 928.85  -  929.0 0.964 1.0  PM 9K60F2D
101C 928.85  -  929.0 0.964 1.0  PM 4K80F2D
101C 928.85  -  929.0 0.964 1.0  PM 1K10F2D
101C 928.85  -  929.0 0.964 1.0  PM 5K00F1D
101C 928.85  -  929.0 0.964 1.0  PM 5K60F1D
101C 928.85  -  929.0 0.964 1.0  PM 5K90F1D
101C 928.85  -  929.0 0.964 1.0  PM 10K0F1D
101C 928.85  -  929.0 0.964 1.0  PM 11K3F1D
101C 928.85  -  929.0 0.964 1.0  PM 11K9F1D
101C 928.85  -  929.0 0.964 1.0  PM 1K30F1D
101C 932.0  -  932.5 0.962 1.0  PM 9K60F2D
101C 932.0  -  932.5 0.962 1.0  PM 4K80F2D
101C 932.0  -  932.5 0.962 1.0  PM 1K10F2D
101C 932.0  -  932.5 0.962 1.0  PM 5K00F1D
101C 932.0  -  932.5 0.962 1.0  PM 5K60F1D
101C 932.0  -  932.5 0.962 1.0  PM 5K90F1D
101C 932.0  -  932.5 0.962 1.0  PM 10K0F1D
101C 932.0  -  932.5 0.962 1.0  PM 11K3F1D
101C 932.0  -  932.5 0.962 1.0  PM 11K9F1D
101C 932.0  -  932.5 0.962 1.0  PM 1K30F1D
101C 941.0  -  941.5 0.935 1.0  PM 5K90F1D
101C 941.0  -  941.5 0.935 1.0  PM 11K8F1D
101C 952.0  -  953.0 0.916 1.0  PM 5K90F1D
101C 952.0  -  953.0 0.916 1.0  PM 11K8F1D
101C 959.85  -  960.0 0.906 1.0  PM 5K90F1D
101C 959.85  -  960.0 0.906 1.0  PM 11K8F1D

Power listed is average conducted. This grant is valid only when the device is installed by the grantee or contractors employed by the grantee who are instructed to ensure that the end-user has no manual instructions to remove or install the device. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Co-located with FCC ID: SDBSNUSCM1.