FCC ID SIZ001

Fire Fighter Telemetry Entry Control Board

by Draeger Safety Ltd

Grantee Code: SIZ   Product Code: 001
Latest application date: 2005-05-17

FCC ID Device Details

FCC IDSIZ001
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSIZ
Product Code001
Applicant BusinessDraeger Safety Ltd 🇬🇧
Related Domains draeger.com
Equipment ClassFire Fighter Telemetry Entry Control Board
Test FirmRFI Global Services Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-470 MHzOriginal Equipment2005-05-17
0.125 MHzOriginal Equipment2005-05-17

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2005-05-17PDF 606.1 KB
Internal PhotographsInternal Photos2005-05-17PDF 536 KB
External PhotographsExternal Photos2005-05-17PDF 141.8 KB
Label LayoutID Label/Location Info2005-05-17PDF 25.1 KB
Test Setup PhotographsTest Setup Photos2005-05-17PDF 202.6 KB
Test ReportTest Report2005-05-17PDF 1.6 MB
Confidentiality LetterCover Letter(s)2005-05-17PDF 43.6 KB
Request to correct Grant errorsCover Letter(s)2005-05-17PDF 36.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 68.1 KB
Schematics Metadata onlySchematicsPDF 2 MB
Operational Description Metadata onlyOperational DescriptionPDF 53 KB
Parts List and Tune up information Metadata onlyParts List/Tune Up InfoPDF 973.1 KB

Application Information

Application IDSoOPOOSqhJjlYIw9nbLVcA==
Final Action Date2005-05-17
Application PurposeOriginal Equipment
Applicant FRN0010659621
Model001
Frequency Range450-470 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionFire Fighter Telemetry Entry Control Board
Responsible PartyMarcus Berney-Smith, marcus.berney-smith@draeger.com , 01670 561350
Test FirmAllan Hume, RFI Global Services Ltd., alan.hume@rfi-global.com , 44-1256-855439
TCB Emailnick.cobb@rfi-global.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsMobile transmitter. Power is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. All qualified end users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the occupational/controlled MPE exposure limits. Users must be provided with training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
SoOPOOSqhJjlYIw9nbLVcA==2005-05-17Original Equipment
Cx5mOXxuGS+gVGdxz3ZjMg==2005-05-17Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
0.125 MHz15C
450-470 MHz0.79400001.3000000000ppm3K76F7D90

Grants

TCB Grant - Application SoOPOOSqhJjlYIw9nbLVcA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL International (UK) Ltd
Unit 1 - 3 Horizon Kingsland Business Park Wade Road
Basingstoke, RG24 8AH
United Kingdom
Date of Grant: 05/17/2005

Application Dated: 05/17/2005
Draeger Safety Ltd
Kitty Brewster Est
Blyth
Blyth, Northumberland, NE244RG
United Kingdom
 
Attention: Marcus Berney-Smith

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SIZ001
Name of Grantee:  Draeger Safety Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Fire Fighter Telemetry Entry Control Board
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 450.0  -  470.0 0.794 1.3  PM 3K76F7D

Mobile transmitter. Power is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. All qualified end users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the occupational/controlled MPE exposure limits. Users must be provided with training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application SoOPOOSqhJjlYIw9nbLVcA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Draeger Safety Ltd
Kitty Brewster Est Blyth
Blyth, Northumberland, NE244RG
United Kingdom
  Date of Grant: 05/17/2005

Application Dated: 05/17/2005
 
Attention: Marcus Berney-Smith

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SIZ001
Name of Grantee:  Draeger Safety Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Fire Fighter Telemetry Entry Control Board
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 450.0  -  470.0 0.794 1.3  PM 3K76F7D

Mobile transmitter. Power is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. All qualified end users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the occupational/controlled MPE exposure limits. Users must be provided with training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance.



TCB Grant - Application Cx5mOXxuGS+gVGdxz3ZjMg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL International (UK) Ltd
Unit 1 - 3 Horizon Kingsland Business Park Wade Road
Basingstoke, RG24 8AH
United Kingdom
Date of Grant: 05/17/2005

Application Dated: 05/17/2005
Draeger Safety Ltd
Kitty Brewster Est
Blyth
Blyth, Northumberland, NE244RG
United Kingdom
 
Attention: Marcus Berney-Smith

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SIZ001
Name of Grantee:  Draeger Safety Ltd
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Fire Fighter Telemetry Entry Control Board
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 0.125  -  0.125  

The antenna used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons.

EAS Grant - Application Cx5mOXxuGS+gVGdxz3ZjMg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Draeger Safety Ltd
Kitty Brewster Est Blyth
Blyth, Northumberland, NE244RG
United Kingdom
  Date of Grant: 05/17/2005

Application Dated: 05/17/2005
 
Attention: Marcus Berney-Smith

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SIZ001
Name of Grantee:  Draeger Safety Ltd
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Fire Fighter Telemetry Entry Control Board
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 0.125  -  0.125  

The antenna used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons.



Mail To: