FCC ID SIZ003

Fire Fighter Telemetry Repeater Unit

by Draeger Safety Ltd

Grantee Code: SIZ   Product Code: 003
Latest application date: 2005-08-23

FCC ID Device Details

FCC IDSIZ003
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSIZ
Product Code003
Applicant BusinessDraeger Safety Ltd 🇬🇧
Related Domains draeger.com
Equipment ClassFire Fighter Telemetry Repeater Unit
Test FirmRFI Global Services Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-470 MHzOriginal Equipment2005-08-23

Exhibits

DocumentTypeAvailableFile
User GuideUsers Manual2005-08-23PDF 94.4 KB
Internal PhotographsInternal Photos2005-08-23PDF 493 KB
External PhotographsExternal Photos2005-08-23PDF 68.7 KB
ID LabelID Label/Location Info2005-08-23PDF 59.1 KB
Test ReportTest Report2005-08-23PDF 710.8 KB
Confidentiality RequestCover Letter(s)2005-08-23PDF 42.8 KB
Block Diagram Metadata onlyBlock DiagramPDF 67.8 KB
Schematic Diagrams Metadata onlySchematicsPDF 452 KB
Operational Description Metadata onlyOperational DescriptionPDF 46.1 KB
Parts List Tune Up Information Metadata onlyParts List/Tune Up InfoPDF 447.3 KB

Application Information

Application IDnAjeEnqGHPv3Nk2i9Z4fFg==
Final Action Date2005-08-23
Application PurposeOriginal Equipment
Applicant FRN0010659621
Model003
Frequency Range450-470 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionFire Fighter Telemetry Repeater Unit
Responsible PartyMarcus Berney-Smith, marcus.berney-smith@draeger.com , 01670 561350
Test FirmAllan Hume, RFI Global Services Ltd., alan.hume@rfi-global.com , 44-1256-855439
TCB Emailnick.cobb@rfi-global.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsMobile transmitter. Power is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. All qualified end users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the occupational/controlled MPE exposure limits. Users must be provided with training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
nAjeEnqGHPv3Nk2i9Z4fFg==2005-08-23Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
450-470 MHz0.66000002.2000000000ppm4K06F7D90

Grants

TCB Grant - Application nAjeEnqGHPv3Nk2i9Z4fFg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL International (UK) Ltd
Unit 1 - 3 Horizon Kingsland Business Park Wade Road
Basingstoke, RG24 8AH
United Kingdom
Date of Grant: 08/23/2005

Application Dated: 08/23/2005
Draeger Safety Ltd
Kitty Brewster Est
Blyth
Blyth, Northumberland, NE244RG
United Kingdom
 
Attention: Marcus Berney-Smith

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SIZ003
Name of Grantee:  Draeger Safety Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Fire Fighter Telemetry Repeater Unit
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 450.0  -  470.0 0.66 2.2  PM 4K06F7D

Mobile transmitter. Power is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. All qualified end users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the occupational/controlled MPE exposure limits. Users must be provided with training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application nAjeEnqGHPv3Nk2i9Z4fFg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Draeger Safety Ltd
Kitty Brewster Est Blyth
Blyth, Northumberland, NE244RG
United Kingdom
  Date of Grant: 08/23/2005

Application Dated: 08/23/2005
 
Attention: Marcus Berney-Smith

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SIZ003
Name of Grantee:  Draeger Safety Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Fire Fighter Telemetry Repeater Unit
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 450.0  -  470.0 0.66 2.2  PM 4K06F7D

Mobile transmitter. Power is ERP. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. All qualified end users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the occupational/controlled MPE exposure limits. Users must be provided with training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: