FCC ID SK9AMI-2A

CENTRON OpenWay Electricity Meter

by Itron, Inc.

Grantee Code: SK9   Product Code: AMI2A
Latest application date: 2009-04-24

FCC ID Device Details

FCC IDSK9AMI-2A
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSK9
Product CodeAMI2A
Applicant BusinessItron, Inc. 🇺🇸
Related Domains itron.com
Equipment ClassCENTRON OpenWay Electricity Meter
Test FirmAdvanced Compliance Solutions, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2405-2480 MHzClass II permissive change or modification of presently authorized equipment2009-04-24
2405-2475 MHzClass II permissive change or modification of presently authorized equipment2009-04-24
902.25-927.75 MHzClass II permissive change or modification of presently authorized equipment2009-04-24
902.25-927.75 MHzClass II permissive change or modification of presently authorized equipment2009-01-26
2405-2480 MHzClass II permissive change or modification of presently authorized equipment2009-01-23
2405-2475 MHzClass II permissive change or modification of presently authorized equipment2009-01-23
902.25-927.75 MHzClass II permissive change or modification of presently authorized equipment2008-10-03
902.25-927.75 MHzClass II permissive change or modification of presently authorized equipment2007-11-27
2405-2475 MHzClass II permissive change or modification of presently authorized equipment2007-11-26
2405-2480 MHzClass II permissive change or modification of presently authorized equipment2007-11-26
2405-2475 MHzOriginal Equipment2007-10-04
2405-2480 MHzOriginal Equipment2007-10-04
902.25-927.75 MHzOriginal Equipment2007-10-04

Exhibits

DocumentTypeAvailableFile
EXTERNAL PHOTOSExternal Photos2007-10-04PDF 530.9 KB
Label InformationID Label/Location Info2009-04-24PDF 588.2 KB
Label InformationID Label/Location Info2009-01-26PDF 311.4 KB
ID LABEL INFORMATIONID Label/Location Info2007-10-04PDF 117.2 KB
Test Setup PhotosTest Setup Photos2008-10-03PDF 255 KB
TEST SETUP PHOTOSTest Setup Photos2007-10-04PDF 412.2 KB
Test ReportTest Report2008-10-03PDF 340.5 KB
TEST REPORTTest Report2007-10-04PDF 290.7 KB
TEST REPORTTest Report2007-10-04PDF 322.4 KB
TEST REPORTTest Report2007-10-04PDF 147.7 KB
Agency AgreementCover Letter(s)2009-04-24PDF 27 KB
FCC Confidentiality RequestCover Letter(s)2009-04-24PDF 19 KB
FCC Cover LetterCover Letter(s)2009-04-24PDF 17.5 KB
Agency AgreementCover Letter(s)2009-01-26PDF 26.5 KB
Confidentiality RequestCover Letter(s)2009-01-26PDF 19 KB
FCC Cover LetterCover Letter(s)2009-01-26PDF 17.8 KB
Agency AgreementCover Letter(s)2008-10-03PDF 26 KB
Cover letterCover Letter(s)2008-10-03PDF 17.9 KB
CONFIDENTIALITY LETTERCover Letter(s)2007-11-27PDF 26 KB
COVER LETTERCover Letter(s)2007-11-27PDF 18.2 KB
CONFIDENTIALITY REQUESTCover Letter(s)2007-10-04PDF 26.2 KB
RF ExposureRF Exposure Info2009-04-24PDF 39 KB
RF ExposureRF Exposure Info2009-01-26PDF 39.1 KB
RF EXPOSURERF Exposure Info2007-11-27PDF 39.2 KB
RF EXPOSURERF Exposure Info2007-10-04PDF 39.2 KB

Application Information

Application IDdHx9XwMgggJFBqBueaHXZQ==
Final Action Date2009-04-24
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0006329973
ModelAMI-2A
Frequency Range2405-2480 MHz
Equipment ClassDXX - Part 15 Low Power Communication Device Transmitter
Device DescriptionCENTRON OpenWay Electricity Meter
Responsible PartyLee Littlejohn, Compliance Engineer, Lee.Littlejohn@itron.com , 864-638-4761
AgentKirby Kirby Kirby, Advanced Compliance Solutions, Inc., kmunroe@acstestlab.com , 770 831 8048
Test FirmSam Wismer, Advanced Compliance Solutions, Inc., swismer@acstestlab.com , 770-831-8048
TCB Emailjwoods@acstestlab.com
TCB ScopeA2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsThis device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. (Original grant notes 10/04/07). This class two change replaces the co-located device FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7NMC8790.

Applications

Application IDDatePurpose
dHx9XwMgggJFBqBueaHXZQ==2009-04-24Class II permissive change or modification of presently authorized equipment
E2wYSNAIbtJQLldZ2vI8nA==2009-04-24Class II permissive change or modification of presently authorized equipment
3DkAbdANtaF90hT2cPOoPw==2009-04-24Class II permissive change or modification of presently authorized equipment
D9jenpKxJq9nr6GjzuXfIQ==2009-01-26Class II permissive change or modification of presently authorized equipment
QBylgxjfMETAbL9Xtw74fw==2009-01-23Class II permissive change or modification of presently authorized equipment
O4/kj/idkmIc7hhEpnDWkw==2009-01-23Class II permissive change or modification of presently authorized equipment
kMf9J+ZEY7PE6oKb/UxxwA==2008-10-03Class II permissive change or modification of presently authorized equipment
HCvusuTIpI26U1bSOaTVEg==2007-11-27Class II permissive change or modification of presently authorized equipment
o2E5rn+6wSchdswXMxSfeQ==2007-11-26Class II permissive change or modification of presently authorized equipment
R1R6Kzm4EO3g+3/hJXfBnA==2007-11-26Class II permissive change or modification of presently authorized equipment
icMT//dT/wXENYbZFABKJg==2007-10-04Original Equipment
d465gzBZuGVQ86bGi+Y8nA==2007-10-04Original Equipment
c9Zlr1FYQYSPcKA5neWx+A==2007-10-04Original Equipment

Equipment Authorization

FrequencyOutputRules
902.25-927.75 MHz0.156000015C
2405-2480 MHz15C
2405-2475 MHz0.074000015C

Grants

TCB Grant - Application R1R6Kzm4EO3g+3/hJXfBnA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 11/26/2007

Application Dated: 11/21/2007
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: CENTRON OPENWAY ELECTRICITY METER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0  

This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %.

EAS Grant - Application R1R6Kzm4EO3g+3/hJXfBnA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 11/26/2007

Application Dated: 11/21/2007
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: CENTRON OPENWAY ELECTRICITY METER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0  

This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %.



TCB Grant - Application QBylgxjfMETAbL9Xtw74fw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 01/23/2009

Application Dated: 01/16/2009
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: CENTRON Openway Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0  

This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. (Original grant notes 10/04/07).

This class two change replaces the co-located device FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7N-MC5725.


EAS Grant - Application QBylgxjfMETAbL9Xtw74fw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 01/23/2009

Application Dated: 01/16/2009
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: CENTRON Openway Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0  

This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. (Original grant notes 10/04/07).

This class two change replaces the co-located device FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7N-MC5725.



TCB Grant - Application O4/kj/idkmIc7hhEpnDWkw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 01/23/2009

Application Dated: 01/16/2009
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON Openway Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.074  

Power listed is conducted. This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class two change replaces the co-located device FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7N-MC5725.


EAS Grant - Application O4/kj/idkmIc7hhEpnDWkw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 01/23/2009

Application Dated: 01/16/2009
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON Openway Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.074  

Power listed is conducted. This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class two change replaces the co-located device FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7N-MC5725.



TCB Grant - Application o2E5rn+6wSchdswXMxSfeQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 11/26/2007

Application Dated: 11/21/2007
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON OPENWAY ELECTRICITY METER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.074  

Power listed is conducted. This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class 2 permissive change adds co-location with specific antenna and transmitter FCCID: RTTAB-WLNB integrated into the Itron Electricity Metering Inc. electricity meter model CVSOR-A.


EAS Grant - Application o2E5rn+6wSchdswXMxSfeQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 11/26/2007

Application Dated: 11/21/2007
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON OPENWAY ELECTRICITY METER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.074  

Power listed is conducted. This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class 2 permissive change adds co-location with specific antenna and transmitter FCCID: RTTAB-WLNB integrated into the Itron Electricity Metering Inc. electricity meter model CVSOR-A.



TCB Grant - Application kMf9J+ZEY7PE6oKb/UxxwA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 10/03/2008

Application Dated: 10/03/2008
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON OpenWay Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.156  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class 2 permissive change adds co-location with specific antenna and transmitter FCCID: RTTAB-WLNB integrated into the Itron Electricity Metering Inc. electricity meter model CVSOR-A. (Grant notes 11/27/07)


EAS Grant - Application kMf9J+ZEY7PE6oKb/UxxwA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 10/03/2008

Application Dated: 10/03/2008
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON OpenWay Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.156  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class 2 permissive change adds co-location with specific antenna and transmitter FCCID: RTTAB-WLNB integrated into the Itron Electricity Metering Inc. electricity meter model CVSOR-A. (Grant notes 11/27/07)



TCB Grant - Application icMT//dT/wXENYbZFABKJg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 10/04/2007

Application Dated: 10/03/2007
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON OPEN WAY ELECTRICITY METER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.074  

Power listed is conducted. This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application icMT//dT/wXENYbZFABKJg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 10/04/2007

Application Dated: 10/03/2007
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON OPEN WAY ELECTRICITY METER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.074  

Power listed is conducted. This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.



TCB Grant - Application HCvusuTIpI26U1bSOaTVEg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 11/27/2007

Application Dated: 11/21/2007
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON OPENWAY ELECTRICITY METER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.156  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class 2 permissive change adds co-location with specific antenna and transmitter FCCID: RTTAB-WLNB integrated into the Itron Electricity Metering Inc. electricity meter model CVSOR-A.


EAS Grant - Application HCvusuTIpI26U1bSOaTVEg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 11/27/2007

Application Dated: 11/21/2007
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON OPENWAY ELECTRICITY METER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.156  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class 2 permissive change adds co-location with specific antenna and transmitter FCCID: RTTAB-WLNB integrated into the Itron Electricity Metering Inc. electricity meter model CVSOR-A.



TCB Grant - Application E2wYSNAIbtJQLldZ2vI8nA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 04/24/2009

Application Dated: 04/22/2009
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON OpenWay Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.074  

Power listed is conducted. This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class two change replaces the co-located device FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7NMC8790.


EAS Grant - Application E2wYSNAIbtJQLldZ2vI8nA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 04/24/2009

Application Dated: 04/22/2009
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON OpenWay Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.074  

Power listed is conducted. This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class two change replaces the co-located device FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7NMC8790.



TCB Grant - Application dHx9XwMgggJFBqBueaHXZQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 04/24/2009

Application Dated: 04/22/2009
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: CENTRON OpenWay Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0  

This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. (Original grant notes 10/04/07).

This class two change replaces the co-located device FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7NMC8790.


EAS Grant - Application dHx9XwMgggJFBqBueaHXZQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 04/24/2009

Application Dated: 04/22/2009
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: CENTRON OpenWay Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0  

This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %. (Original grant notes 10/04/07).

This class two change replaces the co-located device FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7NMC8790.



TCB Grant - Application D9jenpKxJq9nr6GjzuXfIQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 01/26/2009

Application Dated: 01/16/2009
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON Openway Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.156  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class 2 change replaces the co-located module FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7N-MC5725.


EAS Grant - Application D9jenpKxJq9nr6GjzuXfIQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 01/26/2009

Application Dated: 01/16/2009
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON Openway Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.156  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class 2 change replaces the co-located module FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7N-MC5725.



TCB Grant - Application d465gzBZuGVQ86bGi+Y8nA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 10/04/2007

Application Dated: 10/03/2007
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: CENTRON OPEN WAY ELECTRICITY METER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0  

This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %.

EAS Grant - Application d465gzBZuGVQ86bGi+Y8nA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 10/04/2007

Application Dated: 10/03/2007
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: CENTRON OPEN WAY ELECTRICITY METER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0  

This device must transmit with a source-based time-averaging duty factor not exceeding 1.4 %.



TCB Grant - Application c9Zlr1FYQYSPcKA5neWx+A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 10/04/2007

Application Dated: 10/03/2007
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON OPEN WAY ELECTRICITY METER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.156  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application c9Zlr1FYQYSPcKA5neWx+A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 10/04/2007

Application Dated: 10/03/2007
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON OPEN WAY ELECTRICITY METER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.156  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.



TCB Grant - Application 3DkAbdANtaF90hT2cPOoPw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 04/24/2009

Application Dated: 04/22/2009
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON OpenWay Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.156  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class 2 change replaces the co-located module FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7NMC8790.


EAS Grant - Application 3DkAbdANtaF90hT2cPOoPw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 04/24/2009

Application Dated: 04/22/2009
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-2A
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON OpenWay Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.156  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as evaluated in this composite filing with FCCID: MIVGSM0108. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. (Original grant notes 10/04/07).

This class 2 change replaces the co-located module FCC ID: MIVGSM0108 in the orginal filing with co-located module FCC ID: N7NMC8790.



Mail To: