FCC ID SK9AMI-3

CENTRON II Electricity Meter

by Itron, Inc.

Grantee Code: SK9   Product Code: AMI3
Latest application date: 2011-07-29

FCC ID Device Details

FCC IDSK9AMI-3
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSK9
Product CodeAMI3
Applicant BusinessItron, Inc. 🇺🇸
Related Domains itron.com
Equipment ClassCENTRON II Electricity Meter
Test FirmAdvanced Compliance Solutions, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.25-927.75 MHzClass II permissive change or modification of presently authorized equipment2011-07-29
902.25-927.75 MHzClass II permissive change or modification of presently authorized equipment2010-01-13
902.25-927.75 MHzClass II permissive change or modification of presently authorized equipment2009-05-08
2405-2475 MHzClass II permissive change or modification of presently authorized equipment2009-05-08
902.25-927.75 MHzClass II permissive change or modification of presently authorized equipment2008-09-08
902.25-927.75 MHzOriginal Equipment2008-04-15
2405-2475 MHzOriginal Equipment2008-04-15

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2011-07-29PDF 1.3 MB
EXTERNAL PHOTOSExternal Photos2008-04-15PDF 403 KB
LABEL INFOID Label/Location Info2008-04-15PDF 142.4 KB
Test Setup PhotosTest Setup Photos2011-07-29PDF 1.3 MB
Test Setup PhotosTest Setup Photos2010-01-13PDF 468.8 KB
Test Setup PhotosTest Setup Photos2009-05-08PDF 287.9 KB
Test Setup PhotosTest Setup Photos2008-09-08PDF 384.2 KB
TEST SETUP PHOTOSTest Setup Photos2008-04-15PDF 189.8 KB
Test ReportTest Report2011-07-29PDF 81.2 KB
Test ReportTest Report2010-01-13PDF 292.8 KB
Test ReportTest Report2009-05-08PDF 75.5 KB
Test ReportTest Report2009-05-08PDF 81.8 KB
Test ReportTest Report2008-09-08PDF 314.7 KB
TEST REPORTTest Report2008-04-15PDF 251.6 KB
TEST REPORTTest Report2008-04-15PDF 280.6 KB
Agency AgreementCover Letter(s)2011-07-29PDF 27.6 KB
FCC Cover LetterCover Letter(s)2011-07-29PDF 17.3 KB
Agency AgreementCover Letter(s)2010-01-13PDF 27.6 KB
FCC Cover LetterCover Letter(s)2010-01-13PDF 17.3 KB
Agency AgreementCover Letter(s)2009-05-08PDF 26.9 KB
FCC Cover LetterCover Letter(s)2009-05-08PDF 19.6 KB
Agency AgreementCover Letter(s)2008-09-08PDF 26.6 KB
Cover LetterCover Letter(s)2008-09-08PDF 18 KB
AGENCY AGREEMENTCover Letter(s)2008-04-15PDF 28 KB
CONFIDENTIAL LETTERCover Letter(s)2008-04-15PDF 30.1 KB
RF EXPOSURERF Exposure Info2008-04-15PDF 30.6 KB

Application Information

Application IDc1SgHfEhEqkC6Czs0nS+EQ==
Final Action Date2011-07-29
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0006329973
ModelAMI-3
Frequency Range902.25-927.75 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionCENTRON II Electricity Meter
Responsible PartyLee Littlejohn, Compliance Engineer, Lee.Littlejohn@itron.com , 864-638-4761
AgentSam Sam Sam, Advanced Compliance Solutions, Inc., swismer@acstestlab.com , 770 831 8048
Test FirmRandy Abernathy, Advanced Compliance Solutions, Inc., rabernathy@acstestlab.com , 770-831-8048
TCB Emailjwoods@acstestlab.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Class II Change adds new antenna types as described in this filing.

Applications

Application IDDatePurpose
c1SgHfEhEqkC6Czs0nS+EQ==2011-07-29Class II permissive change or modification of presently authorized equipment
sjaNMmP0aXmCLTEs36G45Q==2010-01-13Class II permissive change or modification of presently authorized equipment
n3A+xZfeERe6ABLctNUHmg==2009-05-08Class II permissive change or modification of presently authorized equipment
JT17kDQJkFFW9DLTSNtWUA==2009-05-08Class II permissive change or modification of presently authorized equipment
gVgroXff8aB+2Pf8o161jQ==2008-09-08Class II permissive change or modification of presently authorized equipment
vK1yyiyeYflSMNW9SVMQpg==2008-04-15Original Equipment
5bpP5TyAjsAIjTE+G1FMMA==2008-04-15Original Equipment

Equipment Authorization

FrequencyOutputRules
902.25-927.75 MHz0.149000015C
2405-2475 MHz0.053000015C

Grants

TCB Grant - Application vK1yyiyeYflSMNW9SVMQpg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 04/15/2008

Application Dated: 04/11/2008
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON II ELECTRICITY METER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.149  

Power listed is conducted.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


EAS Grant - Application vK1yyiyeYflSMNW9SVMQpg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 04/15/2008

Application Dated: 04/11/2008
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON II ELECTRICITY METER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.149  

Power listed is conducted.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



TCB Grant - Application sjaNMmP0aXmCLTEs36G45Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 01/13/2010

Application Dated: 01/13/2010
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON II Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.149  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Class II Change adds an additional data rate as described in this filing.


EAS Grant - Application sjaNMmP0aXmCLTEs36G45Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 01/13/2010

Application Dated: 01/13/2010
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON II Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.149  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Class II Change adds an additional data rate as described in this filing.



TCB Grant - Application n3A+xZfeERe6ABLctNUHmg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 05/08/2009

Application Dated: 05/08/2009
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON II Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.149  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application n3A+xZfeERe6ABLctNUHmg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 05/08/2009

Application Dated: 05/08/2009
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON II Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.149  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



TCB Grant - Application JT17kDQJkFFW9DLTSNtWUA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 05/08/2009

Application Dated: 05/08/2009
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON II Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.053  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application JT17kDQJkFFW9DLTSNtWUA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 05/08/2009

Application Dated: 05/08/2009
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON II Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.053  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



TCB Grant - Application gVgroXff8aB+2Pf8o161jQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 09/08/2008

Application Dated: 09/08/2008
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON II Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.149  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application gVgroXff8aB+2Pf8o161jQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 09/08/2008

Application Dated: 09/08/2008
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON II Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.149  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



TCB Grant - Application c1SgHfEhEqkC6Czs0nS+EQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 07/29/2011

Application Dated: 07/29/2011
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON II Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.149  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Class II Change adds new antenna types as described in this filing.


EAS Grant - Application c1SgHfEhEqkC6Czs0nS+EQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 07/29/2011

Application Dated: 07/29/2011
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON II Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.149  

Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Class II Change adds new antenna types as described in this filing.



TCB Grant - Application 5bpP5TyAjsAIjTE+G1FMMA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 04/15/2008

Application Dated: 04/11/2008
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON II ELECTRICITY METER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.053  

Power listed is conducted.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


EAS Grant - Application 5bpP5TyAjsAIjTE+G1FMMA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 04/15/2008

Application Dated: 04/11/2008
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-3
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON II ELECTRICITY METER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.053  

Power listed is conducted.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: