FCC ID SK9AMI-5

CENTRON OpenWay Electricity Meter

by Itron, Inc.

Grantee Code: SK9   Product Code: AMI5
Latest application date: 2009-03-23

FCC ID Device Details

FCC IDSK9AMI-5
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSK9
Product CodeAMI5
Applicant BusinessItron, Inc. 🇺🇸
Related Domains itron.com
Equipment ClassCENTRON OpenWay Electricity Meter
Test FirmAdvanced Compliance Solutions, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.25-927.75 MHzOriginal Equipment2009-03-23
2405-2475 MHzOriginal Equipment2009-03-23

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2009-03-23PDF 258.4 KB
Label InformationID Label/Location Info2009-03-23PDF 123.5 KB
Test Setup PhotosTest Setup Photos2009-03-23PDF 382.9 KB
Test ReportTest Report2009-03-23PDF 416.7 KB
Test ReportTest Report2009-03-23PDF 382.1 KB
Agency AgreementCover Letter(s)2009-03-23PDF 34.2 KB
FCC Confidentiality RequestCover Letter(s)2009-03-23PDF 19.3 KB
FCC Cover LetterCover Letter(s)2009-03-23PDF 17.7 KB
RF ExposureRF Exposure Info2009-03-23PDF 30.4 KB

Application Information

Application IDcU0dDdW9JowxgUJUOycP3g==
Final Action Date2009-03-23
Application PurposeOriginal Equipment
Applicant FRN0006329973
ModelAMI-5
Frequency Range902.25-927.75 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionCENTRON OpenWay Electricity Meter
Responsible PartyLee Littlejohn, Compliance Engineer, Lee.Littlejohn@itron.com , 864-638-4761
AgentKirby Kirby Kirby, Advanced Compliance Solutions, Inc., kmunroe@acstestlab.com , 770 831 8048
Test FirmSam Wismer, Advanced Compliance Solutions, Inc., swismer@acstestlab.com , 770-831-8048
TCB Emailjwoods@acstestlab.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsPower listed is conducted. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except as evaluated in this filing. End-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Grantee must ensure that the end-user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.

Applications

Application IDDatePurpose
cU0dDdW9JowxgUJUOycP3g==2009-03-23Original Equipment
Jsfag+hbZhytmQoa4qnYBA==2009-03-23Original Equipment

Equipment Authorization

FrequencyOutputRules
902.25-927.75 MHz0.141000015C
2405-2475 MHz0.050000015C

Grants

TCB Grant - Application Jsfag+hbZhytmQoa4qnYBA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 03/23/2009

Application Dated: 03/20/2009
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-5
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON OpenWay Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.05  

Power listed is conducted. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except as evaluated in this filing. End-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Grantee must ensure that the end-user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. Device must transmit with a source-based-time-averaging duty factor not exceeding 27%.

EAS Grant - Application Jsfag+hbZhytmQoa4qnYBA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 03/23/2009

Application Dated: 03/20/2009
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-5
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Digital Transmission System
Notes: CENTRON OpenWay Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2475.0 0.05  

Power listed is conducted. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except as evaluated in this filing. End-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Grantee must ensure that the end-user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations. Device must transmit with a source-based-time-averaging duty factor not exceeding 27%.



TCB Grant - Application cU0dDdW9JowxgUJUOycP3g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Advanced Compliance Solutions, Inc.
5015 B.U. Bowman Drive
Buford, GA 30518
Date of Grant: 03/23/2009

Application Dated: 03/20/2009
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-5
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON OpenWay Electricity Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.141  

Power listed is conducted. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except as evaluated in this filing. End-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Grantee must ensure that the end-user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.

EAS Grant - Application cU0dDdW9JowxgUJUOycP3g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696
United States
  Date of Grant: 03/23/2009

Application Dated: 03/20/2009
 
Attention: Lee Littlejohn , Compliance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SK9AMI-5
Name of Grantee:  Itron Electricity Metering, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: CENTRON OpenWay Electricity Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.25  -  927.75 0.141  

Power listed is conducted. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except as evaluated in this filing. End-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Grantee must ensure that the end-user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.



Mail To: