FCC ID SLRHS5S

Vista

by iHealth Labs, Inc.

Grantee Code: SLR   Product Code: HS5S
Latest application date: 2015-06-03

FCC ID Device Details

FCC IDSLRHS5S
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSLR
Product CodeHS5S
Applicant BusinessiHealth Labs, Inc. 🇺🇸
Related Domains ihealthlabs.com sgs.com
Equipment ClassVista
Test FirmSGS-CSTC Standards Technical Services Co.,Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2015-06-03

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2015-06-03PDF 68.3 KB
HS5S_Internal Photos-FCCInternal Photos2015-06-03PDF 3 MB
HS5S_External Photos-FCCExternal Photos2015-06-03PDF 813.2 KB
Label & LocationID Label/Location Info2015-06-03PDF 1.3 MB
HS5S_Test Setup photos FCC Metadata onlyTest Setup Photos2015-06-03PDF 3.8 MB
HS5S_Test Setup photos FCC-Rev 1.0Test Setup Photos2015-06-03PDF 2.9 MB
SHEM150100013102V00--Report FCC Part 15.247 For WiFi-Rev 1.0Test Report2015-06-03PDF 2.6 MB
DeclarationCover Letter(s)2015-06-03PDF 16.3 KB
FCC-Confidentiality Request LetterCover Letter(s)2015-06-03PDF 36.1 KB
POA Letter for FCCCover Letter(s)2015-06-03PDF 112.8 KB
SZEM1503000939CR--Report FCC SAR--I-Rev1RF Exposure Info2015-06-03PDF 4.6 MB
SZEM1503000939CR--Report FCC SAR--II-Rev1RF Exposure Info2015-06-03PDF 4.1 MB
Block Diagram for Unit Metadata onlyBlock DiagramPDF 9.1 KB
Confidential_Block Diagram for RF module--Rev1 Metadata onlyBlock DiagramPDF 157.3 KB
Confidential_Schematics for RF module Metadata onlySchematicsPDF 460.3 KB
Confidential_Schematics for Unit Metadata onlySchematicsPDF 699.4 KB
Confidential_HF-LPB100--Datasheet-Rev1 Metadata onlyOperational DescriptionPDF 2.9 MB
Confidential_HS5s operational description-Rev 1.0 Metadata onlyOperational DescriptionPDF 18.1 KB
Confidential_Operation Description Metadata onlyOperational DescriptionPDF 15.2 KB

Application Information

Application IDeu1uL6mJX/Z+sTbBi14vuw==
Final Action Date2015-06-03
Application PurposeOriginal Equipment
Applicant FRN0022414882
ModelHS5S
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionVista
Responsible PartyMing Cong, Ming.cong@ihealthlabs.com , 650-961-2818
AgentEddy Eddy Eddy, SGS-CSTC Standards Technical Services (Shangshai), eddy.zong@sgs.com , 86-21-61915664
Technical ContactEddy Zong, SGS-CSTC Standards Technical Services (shanghai), eddy.zong@sgs.com , 86-021-61915664
Non-Technical ContactEddy Zong, SGS-CSTC Standards Technical Services (shanghai), eddy.zong@sgs.com , 86-021-61915664
Test FirmZenger Zhang, SGS-CSTC Standards Technical Services Co.,Ltd., zenger.zhang@sgs.com , 86(0)2161915654
TCB Emailhotline@acbcert.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is conducted. The SAR data in this filing is applicable to demonstrate compliance for the device as shown in this filing. End users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The highest reported SAR values for extremity (feet) exposure condition is 0.13 W/kg; This device has a 20 MHz and 40 MHz bandwidth mode.

Applications

Application IDDatePurpose
eu1uL6mJX/Z+sTbBi14vuw==2015-06-03Original Equipment

Equipment Authorization

FrequencyOutputRules
2412-2462 MHz0.062520015C

Grants

TCB Grant - Application eu1uL6mJX/Z+sTbBi14vuw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 06/03/2015

Application Dated: 06/01/2015
iHealth Labs, Inc.
120 San Lucar Ct., Sunnyvale, CA 94086, USA
Sunnyvale, CA 94086
 
Attention: Ming Cong

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SLRHS5S
Name of Grantee:  iHealth Labs, Inc.
Equipment Class: Digital Transmission System
Notes: Vista
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.06252  

Power Output is conducted. The SAR data in this filing is applicable to demonstrate compliance for the device as shown in this filing. End users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The highest reported SAR values for extremity (feet) exposure condition is 0.13 W/kg;

This device has a 20 MHz and 40 MHz bandwidth mode.


EAS Grant - Application eu1uL6mJX/Z+sTbBi14vuw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

iHealth Labs, Inc.
120 San Lucar Ct., Sunnyvale, CA 94086, USA
Sunnyvale, CA 94086
United States
  Date of Grant: 06/03/2015

Application Dated: 06/01/2015
 
Attention: Ming Cong

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SLRHS5S
Name of Grantee:  iHealth Labs, Inc.
Equipment Class: Digital Transmission System
Notes: Vista
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.06252  

Power Output is conducted. The SAR data in this filing is applicable to demonstrate compliance for the device as shown in this filing. End users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The highest reported SAR values for extremity (feet) exposure condition is 0.13 W/kg;

This device has a 20 MHz and 40 MHz bandwidth mode.