FCC ID SMQ-NANOL12EXP

Nano Series Diagnostic Ultrasound Systen

by EDAN INSTRUMENTS, INC.

Grantee Code: SMQ   Product Code: NANOL12EXP
Latest application date: 2024-07-17

FCC ID Device Details

FCC IDSMQ-NANOL12EXP
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSMQ
Product CodeNANOL12EXP
Applicant BusinessEDAN INSTRUMENTS, INC. 🇨🇳
Related Domains edan.com.cn
Equipment ClassNano Series Diagnostic Ultrasound Systen
Test FirmShenzhen CTL Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2024-07-17

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2025-01-12PDF 4.2 MB
Internal PhotosInternal Photos2024-07-17PDF 940.2 KB
External PhotosExternal Photos2024-07-17PDF 498.7 KB
Label InformationID Label/Location Info2024-07-17PDF 272.6 KB
Test Setup PhotosTest Setup Photos2024-07-17PDF 306 KB
Test Setup Photos SARTest Setup Photos2024-07-17PDF 724.3 KB
Test ReportTest Report2024-07-17PDF 3.2 MB
Test data1Test Report2024-07-17PDF 1.8 MB
Test data2Test Report2024-07-17PDF 1.8 MB
Attestation Statements1Attestation Statements2024-07-17PDF 133.9 KB
Attestation Statements2Attestation Statements2024-07-17PDF 134.9 KB
U.S. Agent Letter of AttestationAttestation Statements2024-07-17PDF 120.6 KB
Agent Authorization Letter TemplateCover Letter(s)2024-07-17PDF 115.6 KB
Antenna ReportCover Letter(s)2024-07-17PDF 1.2 MB
FCC Short & Long Term Confidentiality RequestCover Letter(s)2024-07-17PDF 59.1 KB
FCC Software Configuration Control DeclarationCover Letter(s)2024-07-17PDF 84.9 KB
SAR FCCRF Exposure Info2024-07-17PDF 4.6 MB
Block Diagram Metadata onlyBlock DiagramPDF 93 KB
Schematics Metadata onlySchematicsPDF 153.9 KB
Operational Description Metadata onlyOperational DescriptionPDF 129.8 KB
FCC Software Security Requirements for UNII devices Metadata onlySDR Software/Security Info.PDF 230.9 KB
Tune up Metadata onlyParts List/Tune Up InfoPDF 85.6 KB

Application Information

Application IDaVvTVXHmDc7vKwZ7RRMUzg==
Final Action Date2024-07-17
Application PurposeOriginal Equipment
Applicant FRN0022565113
ModelNANOL12EXP
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionNano Series Diagnostic Ultrasound Systen
Responsible PartyHuanhuan Xia, xiahuanhuan@edan.com.cn , 0086 755 26682547
Technical ContactEDAN INSTRUMENTS, INC., xiahuanhuan@edan.com.cn
Test FirmTracy Qi, Shenzhen CTL Testing Technology Co., Ltd., qihui@ctl-lab.com , 86-755-89486194
TCB Emailanezam@qai.org
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date01/12/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory is 1.16W/kg.

Applications

Application IDDatePurpose
aVvTVXHmDc7vKwZ7RRMUzg==2024-07-17Original Equipment

Equipment Authorization

FrequencyOutputRules
5180-5240 MHz0.02415E
5745-5825 MHz0.015615E

Grants

TCB Grant - Application aVvTVXHmDc7vKwZ7RRMUzg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 07/17/2024

Application Dated: 07/15/2024
EDAN INSTRUMENTS, INC.
#15 Jinhui Road, Jinsha Community,
Kengzi Sub-District, Pingshan District
Shenzhen, 518122
China
 
Attention: Huanhuan Xia

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SMQ-NANOL12EXP
Name of Grantee:  EDAN INSTRUMENTS, INC.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Nano Series Diagnostic Ultrasound Systen
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15E 5745.0  -  5825.0 0.0156  
15E 5180.0  -  5240.0 0.024  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory is 1.16W/kg.

EAS Grant - Application aVvTVXHmDc7vKwZ7RRMUzg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

EDAN INSTRUMENTS, INC.
#15 Jinhui Road, Jinsha Community, Kengzi Sub-District, Pingshan District
Shenzhen, 518122
China
  Date of Grant: 07/17/2024

Application Dated: 07/15/2024
 
Attention: Huanhuan Xia

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SMQ-NANOL12EXP
Name of Grantee:  EDAN INSTRUMENTS, INC.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Nano Series Diagnostic Ultrasound Systen
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15E 5745.0  -  5825.0 0.0156  
15E 5180.0  -  5240.0 0.024  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory is 1.16W/kg.



Mail To: