FCC ID SMQSE120XPRO

Electrocardiograph

by EDAN INSTRUMENTS, INC.

Grantee Code: SMQ   Product Code: SE120XPRO
Latest application date: 2022-09-30

FCC ID Device Details

FCC IDSMQSE120XPRO
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSMQ
Product CodeSE120XPRO
Applicant BusinessEDAN INSTRUMENTS, INC. 🇨🇳
Related Domains edan.com.cn
Equipment ClassElectrocardiograph
Test FirmShenzhen CTL Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2022-09-30
699.7-715.3 MHzOriginal Equipment2022-09-30
2402-2480 MHzOriginal Equipment2022-09-30
2402-2480 MHzOriginal Equipment2022-09-30

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2022-09-30PDF 2.1 MB
Internal photosInternal Photos2022-09-30PDF 1.8 MB
External photosExternal Photos2022-09-30PDF 565 KB
ID label and locationID Label/Location Info2022-09-30PDF 85.5 KB
Test setup photosTest Setup Photos2022-09-30PDF 182 KB
Test setup photosTest Setup Photos2022-09-30PDF 239.8 KB
Antenna specificationsTest Report2022-09-30PDF 2.1 MB
Test reportsTest Report2022-09-30PDF 4.8 MB
Test reportsTest Report2022-09-30PDF 2.1 MB
Test reportsTest Report2022-09-30PDF 4.6 MB
Test reportsTest Report2022-09-30PDF 5.7 MB
Family declarationAttestation Statements2022-09-30PDF 74.1 KB
ConfidentialityCover Letter(s)2022-09-30PDF 46 KB
Letter AuthorizationCover Letter(s)2022-09-30PDF 44.9 KB
Software Configuration ControlCover Letter(s)2022-09-30PDF 48.3 KB
UNII declaration letterCover Letter(s)2022-09-30PDF 128.1 KB
RF ExposureRF Exposure Info2022-09-30PDF 329.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 1.1 MB
Schematics Metadata onlySchematicsPDF 2.4 MB
Operational Description Metadata onlyOperational DescriptionPDF 91.3 KB
Security Info. Metadata onlySDR Software/Security InfPDF 168.6 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 920 KB
Tune Up Procedurer Metadata onlyParts List/Tune Up InfoPDF 121 KB

Application Information

Application IDo3qW4RnkYpqLrc5hZL51Mg==
Final Action Date2022-09-30
Application PurposeOriginal Equipment
Applicant FRN0022565113
ModelSE120XPRO
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionElectrocardiograph
Responsible PartyHuanhuan Xia, xiahuanhuan@edan.com.cn , 0086 755 26682547
Technical ContactHuanhuan Xia, Edan Instruments, Inc, xiahuanhuan@edan.com , 0086 755 26682547
Test FirmTracy Qi, Shenzhen CTL Testing Technology Co., Ltd., qihui@ctl-lab.com , 86-755-89486194
TCB Emailelabscert@applus.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. This device contains 20MHz, 40MHz and 80MHz signal bandwidth modes.This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection.

Applications

Application IDDatePurpose
o3qW4RnkYpqLrc5hZL51Mg==2022-09-30Original Equipment
luwNQ/uFg1I4/CQ8qjE36Q==2022-09-30Original Equipment
HvvcHALItGc1aLnhPwk96g==2022-09-30Original Equipment
0UZ2PMYyh9SuG7u7zSPP3w==2022-09-30Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
699.7-715.3 MHz0.277972.5ppm1M09G7D27
701.5-713.5 MHz0.209892.5ppm4M55W7D27
704-711 MHz0.27292.5ppm9M06G7D27
704-711 MHz0.207012.5ppm9M05W7D27
706.5-713.5 MHz0.268532.5ppm4M53G7D27
706.5-713.5 MHz0.204642.5ppm4M56W7D27
709-711 MHz0.267922.5ppm9M01G7D27
709-711 MHz0.214292.5ppm8M99W7D27
824.7-848.3 MHz0.327342.5ppm1M10G7D22H
824.7-848.3 MHz0.255862.5ppm1M10W7D22H
829-844 MHz0.24662.5ppm9M00W7D22H
829-844 MHz0.325842.5ppm9M01G7D22H
1720-1745 MHz0.623732.5ppm18M1G7D27
1720-1745 MHz0.472062.5ppm18M1W7D27
1860-1900 MHz0.587492.5ppm18M0G7D24E
1860-1900 MHz0.456042.5ppm18M0W7D24E
2402-2480 MHz0.007816315CCC
2402-2480 MHz0.000431515CCC
2412-2462 MHz0.155596615CCC
2510-2560 MHz0.547022.5ppm18M1G7D27
2510-2560 MHz0.424622.5ppm18M1W7D27
2560-2650 MHz0.352372.5ppm8M99G7D27
2560-2650 MHz0.27042.5ppm8M99W7D27
2565-2645 MHz0.345942.5ppm18M0G7D27
2565-2645 MHz0.281842.5ppm18M0W7D27
5180-5240 MHz0.023280915ECC
5260-5320 MHz0.024378115ECC, ND
5745-5825 MHz0.024154615ECC

Grants

TCB Grant - Application o3qW4RnkYpqLrc5hZL51Mg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 09/30/2022

Application Dated: 09/30/2022
EDAN INSTRUMENTS, INC.
#15 Jinhui Road, Jinsha Community,
Kengzi Sub-District, Pingshan District
Shenzhen, 518122
China
 
Attention: Huanhuan Xia

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SMQSE120XPRO
Name of Grantee:  EDAN INSTRUMENTS, INC.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Electrocardiograph
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0232809  
CC ND 15E 5260.0  -  5320.0 0.0243781  
CC 15E 5745.0  -  5825.0 0.0241546  

Output power listed is conducted. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. This device contains 20MHz, 40MHz and 80MHz signal bandwidth modes.This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection.

CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application o3qW4RnkYpqLrc5hZL51Mg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

EDAN INSTRUMENTS, INC.
#15 Jinhui Road, Jinsha Community, Kengzi Sub-District, Pingshan District
Shenzhen, 518122
China
  Date of Grant: 09/30/2022

Application Dated: 09/30/2022
 
Attention: Huanhuan Xia

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SMQSE120XPRO
Name of Grantee:  EDAN INSTRUMENTS, INC.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Electrocardiograph
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0232809  
CC ND 15E 5260.0  -  5320.0 0.0243781  
CC 15E 5745.0  -  5825.0 0.0241546  

Output power listed is conducted. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. This device contains 20MHz, 40MHz and 80MHz signal bandwidth modes.This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application luwNQ/uFg1I4/CQ8qjE36Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 09/30/2022

Application Dated: 09/30/2022
EDAN INSTRUMENTS, INC.
#15 Jinhui Road, Jinsha Community,
Kengzi Sub-District, Pingshan District
Shenzhen, 518122
China
 
Attention: Huanhuan Xia

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SMQSE120XPRO
Name of Grantee:  EDAN INSTRUMENTS, INC.
Equipment Class: PCS Licensed Transmitter
Notes: Electrocardiograph
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.7  -  1909.3 0.59841 2.5  PM 1M09G7D
24E 1855.0  -  1905.0 0.46238 2.5  PM 9M00W7D
24E 1860.0  -  1900.0 0.58749 2.5  PM 18M0G7D
24E 1860.0  -  1900.0 0.45604 2.5  PM 18M0W7D
27 1720.0  -  1745.0 0.62373 2.5  PM 18M1G7D
27 1720.0  -  1745.0 0.47206 2.5  PM 18M1W7D
22H 824.7  -  848.3 0.32734 2.5  PM 1M10G7D
22H 824.7  -  848.3 0.25586 2.5  PM 1M10W7D
22H 829.0  -  844.0 0.32584 2.5  PM 9M01G7D
22H 829.0  -  844.0 0.2466 2.5  PM 9M00W7D
27 2510.0  -  2560.0 0.54702 2.5  PM 18M1G7D
27 2510.0  -  2560.0 0.42462 2.5  PM 18M1W7D
27 699.7  -  715.3 0.27797 2.5  PM 1M09G7D
27 701.5  -  713.5 0.20989 2.5  PM 4M55W7D
27 704.0  -  711.0 0.2729 2.5  PM 9M06G7D
27 704.0  -  711.0 0.20701 2.5  PM 9M05W7D
27 706.5  -  713.5 0.26853 2.5  PM 4M53G7D
27 706.5  -  713.5 0.20464 2.5  PM 4M56W7D
27 709.0  -  711.0 0.26792 2.5  PM 9M01G7D
27 709.0  -  711.0 0.21429 2.5  PM 8M99W7D
27 2560.0  -  2650.0 0.35237 2.5  PM 8M99G7D
27 2560.0  -  2650.0 0.2704 2.5  PM 8M99W7D
27 2565.0  -  2645.0 0.34594 2.5  PM 18M0G7D
27 2565.0  -  2645.0 0.28184 2.5  PM 18M0W7D

Output power listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

EAS Grant - Application luwNQ/uFg1I4/CQ8qjE36Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

EDAN INSTRUMENTS, INC.
#15 Jinhui Road, Jinsha Community, Kengzi Sub-District, Pingshan District
Shenzhen, 518122
China
  Date of Grant: 09/30/2022

Application Dated: 09/30/2022
 
Attention: Huanhuan Xia

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SMQSE120XPRO
Name of Grantee:  EDAN INSTRUMENTS, INC.
Equipment Class: PCS Licensed Transmitter
Notes: Electrocardiograph
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.7  -  1909.3 0.59841 2.5  PM 1M09G7D
24E 1855.0  -  1905.0 0.46238 2.5  PM 9M00W7D
24E 1860.0  -  1900.0 0.58749 2.5  PM 18M0G7D
24E 1860.0  -  1900.0 0.45604 2.5  PM 18M0W7D
27 1720.0  -  1745.0 0.62373 2.5  PM 18M1G7D
27 1720.0  -  1745.0 0.47206 2.5  PM 18M1W7D
22H 824.7  -  848.3 0.32734 2.5  PM 1M10G7D
22H 824.7  -  848.3 0.25586 2.5  PM 1M10W7D
22H 829.0  -  844.0 0.32584 2.5  PM 9M01G7D
22H 829.0  -  844.0 0.2466 2.5  PM 9M00W7D
27 2510.0  -  2560.0 0.54702 2.5  PM 18M1G7D
27 2510.0  -  2560.0 0.42462 2.5  PM 18M1W7D
27 699.7  -  715.3 0.27797 2.5  PM 1M09G7D
27 701.5  -  713.5 0.20989 2.5  PM 4M55W7D
27 704.0  -  711.0 0.2729 2.5  PM 9M06G7D
27 704.0  -  711.0 0.20701 2.5  PM 9M05W7D
27 706.5  -  713.5 0.26853 2.5  PM 4M53G7D
27 706.5  -  713.5 0.20464 2.5  PM 4M56W7D
27 709.0  -  711.0 0.26792 2.5  PM 9M01G7D
27 709.0  -  711.0 0.21429 2.5  PM 8M99W7D
27 2560.0  -  2650.0 0.35237 2.5  PM 8M99G7D
27 2560.0  -  2650.0 0.2704 2.5  PM 8M99W7D
27 2565.0  -  2645.0 0.34594 2.5  PM 18M0G7D
27 2565.0  -  2645.0 0.28184 2.5  PM 18M0W7D

Output power listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.



TCB Grant - Application HvvcHALItGc1aLnhPwk96g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 09/30/2022

Application Dated: 09/30/2022
EDAN INSTRUMENTS, INC.
#15 Jinhui Road, Jinsha Community,
Kengzi Sub-District, Pingshan District
Shenzhen, 518122
China
 
Attention: Huanhuan Xia

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SMQSE120XPRO
Name of Grantee:  EDAN INSTRUMENTS, INC.
Equipment Class: Digital Transmission System
Notes: Electrocardiograph
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0004315  
CC 15C 2412.0  -  2462.0 0.1555966  

Output power listed is conducted. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.This device contains 20MHz and 40MHz signal bandwidth modes for 2.4GHz WLAN.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application HvvcHALItGc1aLnhPwk96g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

EDAN INSTRUMENTS, INC.
#15 Jinhui Road, Jinsha Community, Kengzi Sub-District, Pingshan District
Shenzhen, 518122
China
  Date of Grant: 09/30/2022

Application Dated: 09/30/2022
 
Attention: Huanhuan Xia

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SMQSE120XPRO
Name of Grantee:  EDAN INSTRUMENTS, INC.
Equipment Class: Digital Transmission System
Notes: Electrocardiograph
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0004315  
CC 15C 2412.0  -  2462.0 0.1555966  

Output power listed is conducted. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.This device contains 20MHz and 40MHz signal bandwidth modes for 2.4GHz WLAN.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 0UZ2PMYyh9SuG7u7zSPP3w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 09/30/2022

Application Dated: 09/30/2022
EDAN INSTRUMENTS, INC.
#15 Jinhui Road, Jinsha Community,
Kengzi Sub-District, Pingshan District
Shenzhen, 518122
China
 
Attention: Huanhuan Xia

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SMQSE120XPRO
Name of Grantee:  EDAN INSTRUMENTS, INC.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Electrocardiograph
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0078163  

Output power listed is conducted. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 0UZ2PMYyh9SuG7u7zSPP3w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

EDAN INSTRUMENTS, INC.
#15 Jinhui Road, Jinsha Community, Kengzi Sub-District, Pingshan District
Shenzhen, 518122
China
  Date of Grant: 09/30/2022

Application Dated: 09/30/2022
 
Attention: Huanhuan Xia

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SMQSE120XPRO
Name of Grantee:  EDAN INSTRUMENTS, INC.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Electrocardiograph
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0078163  

Output power listed is conducted. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: