FCC ID SQMSQ-3500

VoIP Phone

by UniData Communication Systems Inc.

Grantee Code: SQM   Product Code: SQ3500
Latest application date: 2009-12-12

FCC ID Device Details

FCC IDSQMSQ-3500
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSQM
Product CodeSQ3500
Applicant BusinessUniData Communication Systems Inc. 🇰🇷
Related Domains udcsystems.com
Equipment ClassVoIP Phone
Test FirmSGS Korea Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2009-12-12
5180-5240 MHzOriginal Equipment2009-12-12

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2009-12-12PDF 1.8 MB
users manualUsers Manual2009-12-12PDF 1.8 MB
internal photosInternal Photos2009-12-12PDF 257.8 KB
external photosExternal Photos2009-12-12PDF 763.1 KB
ID labelID Label/Location Info2009-12-12PDF 76.8 KB
RF testTest Setup Photos2009-12-12PDF 78.2 KB
RF textTest Setup Photos2009-12-12PDF 76.2 KB
SARTest Setup Photos2009-12-12PDF 375.7 KB
SAR testTest Setup Photos2009-12-12PDF 375.7 KB
RF test reportTest Report2009-12-12PDF 559.3 KB
SAR test reportRF Exposure Info2009-12-12PDF 3.7 MB
testt reportTest Report2009-12-12PDF 914.3 KB
POACover Letter(s)2009-12-12PDF 15.1 KB
request for confidentialityCover Letter(s)2009-12-12PDF 59.1 KB
SAR reportRF Exposure Info2009-12-12PDF 3.7 MB

Application Information

Application IDp5AZO0gyNQ/pruBytoQWSw==
Final Action Date2009-12-12
Application PurposeOriginal Equipment
Applicant FRN0012204178
ModelSQ-3500
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionVoIP Phone
Responsible PartyByeong Gil Park, Manager, bkpark@udcsystems.com , +82-2-3443-3390
Test FirmJulia Choi, SGS Korea Co., Ltd., julia.choi@sgs.com , 82-31-263-0409
TCB Emailmike.kuo@ccsemc.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. This device was tested with a 1.5cm device-to-body spacing gap and was not tested with any body-worn accessories. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user body. End-users must be informed of the bodyworn operating requirements for satisfying RF exposure compliance. Approval is limited to the specific configuration described in this filing. The WLAN antenna(s) used for this device must not be co-located or operating in conjunction with any other antenna or transmitter except as described in this filing. Additional equipment authorization is required for changes that result in the need for SAR evaluation. The highest reported SAR values are: Head: 0.215 W/kg; Body-worn: 0.38 W/kg.

Applications

Application IDDatePurpose
p5AZO0gyNQ/pruBytoQWSw==2009-12-12Original Equipment
chk4L3TvWSYZaZZdkk6iJg==2009-12-12Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.053215CCC
5180-5240 MHz0.035200015ECC
5745-5825 MHz0.044815CCC

Grants

TCB Grant - Application p5AZO0gyNQ/pruBytoQWSw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 12/12/2009

Application Dated: 12/12/2009
UniData Communication Systems Inc.
3F, Burim-Bldg, 837-6, Bangbae4-Dong, Seocho-Gu
Seoul, 137-835
South Korea
 
Attention: Byeong Gil Park , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SQMSQ-3500
Name of Grantee:  UniData Communication Systems Inc.
Equipment Class: Digital Transmission System
Notes: VoIP Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0532  
CC 15C 5745.0  -  5825.0 0.0448  

Power listed is conducted. This device was tested with a 1.5cm device-to-body spacing gap and was not tested with any body-worn accessories. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user body. End-users must be informed of the bodyworn operating requirements for satisfying RF exposure compliance. Approval is limited to the specific configuration described in this filing. The WLAN antenna(s) used for this device must not be co-located or operating in conjunction with any other antenna or transmitter except as described in this filing. Additional equipment authorization is required for changes that result in the need for SAR evaluation. The highest reported SAR values are: Head: 0.215 W/kg; Body-worn: 0.38 W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application p5AZO0gyNQ/pruBytoQWSw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

UniData Communication Systems Inc.
3F, Burim-Bldg, 837-6, Bangbae4-Dong, Seocho-Gu
Seoul, 137-835
South Korea
  Date of Grant: 12/12/2009

Application Dated: 12/12/2009
 
Attention: Byeong Gil Park , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SQMSQ-3500
Name of Grantee:  UniData Communication Systems Inc.
Equipment Class: Digital Transmission System
Notes: VoIP Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0532  
CC 15C 5745.0  -  5825.0 0.0448  

Power listed is conducted. This device was tested with a 1.5cm device-to-body spacing gap and was not tested with any body-worn accessories. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user body. End-users must be informed of the bodyworn operating requirements for satisfying RF exposure compliance. Approval is limited to the specific configuration described in this filing. The WLAN antenna(s) used for this device must not be co-located or operating in conjunction with any other antenna or transmitter except as described in this filing. Additional equipment authorization is required for changes that result in the need for SAR evaluation. The highest reported SAR values are: Head: 0.215 W/kg; Body-worn: 0.38 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application chk4L3TvWSYZaZZdkk6iJg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 12/12/2009

Application Dated: 12/12/2009
UniData Communication Systems Inc.
3F, Burim-Bldg, 837-6, Bangbae4-Dong, Seocho-Gu
Seoul, 137-835
South Korea
 
Attention: Byeong Gil Park , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SQMSQ-3500
Name of Grantee:  UniData Communication Systems Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: VoIP Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0352  

Power listed is conducted. This device was tested with a 1.5cm device-to-body spacing gap and was not tested with any body-worn accessories. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user body. End-users must be informed of the bodyworn operating requirements for satisfying RF exposure compliance. Approval is limited to the specific configuration described in this filing. The WLAN antenna(s) used for this device must not be co-located or operating in conjunction with any other antenna or transmitter except as described in this filing. Additional equipment authorization is required for changes that result in the need for SAR evaluation. The highest reported SAR values are: Head: 0.127 W/kg; Body-worn: 0.38 W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application chk4L3TvWSYZaZZdkk6iJg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

UniData Communication Systems Inc.
3F, Burim-Bldg, 837-6, Bangbae4-Dong, Seocho-Gu
Seoul, 137-835
South Korea
  Date of Grant: 12/12/2009

Application Dated: 12/12/2009
 
Attention: Byeong Gil Park , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SQMSQ-3500
Name of Grantee:  UniData Communication Systems Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: VoIP Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0352  

Power listed is conducted. This device was tested with a 1.5cm device-to-body spacing gap and was not tested with any body-worn accessories. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user body. End-users must be informed of the bodyworn operating requirements for satisfying RF exposure compliance. Approval is limited to the specific configuration described in this filing. The WLAN antenna(s) used for this device must not be co-located or operating in conjunction with any other antenna or transmitter except as described in this filing. Additional equipment authorization is required for changes that result in the need for SAR evaluation. The highest reported SAR values are: Head: 0.127 W/kg; Body-worn: 0.38 W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: