FCC ID SSH-SDMAN

SDIO Wireless Module

by Stryker Endoscopy

Grantee Code: SSH   Product Code: SDMAN
Latest application date: 2013-09-18

FCC ID Device Details

FCC IDSSH-SDMAN
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSSH
Product CodeSDMAN
Applicant BusinessStryker Endoscopy 🇺🇸
Related Domains stryker.com
Equipment ClassSDIO Wireless Module
Test FirmSIEMIC Labs

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5320 MHzClass II permissive change or modification of presently authorized equipment2013-09-18
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2013-09-18
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2013-09-18
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: N6C-SDMAN Grant Date: 08/20/20122013-08-27
5180-5320 MHzChange in identification of presently authorized equipment. Original FCC ID: N6C-SDMAN Grant Date: 05/16/20132013-08-27
2402-2480 MHzChange in identification of presently authorized equipment. Original FCC ID: N6C-SDMAN Grant Date: 08/20/20122013-08-27

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2014-02-23PDF 50.2 KB
Internal Photos - Silex ModuleInternal Photos2013-09-18PDF 258.5 KB
Internal Photos - Silex moduleInternal Photos2013-09-18PDF 258.5 KB
External Photos - Host PhotosExternal Photos2013-09-18PDF 130 KB
External Photos - Silex ModuleExternal Photos2013-09-18PDF 568.9 KB
External Photos - Silex moduleExternal Photos2013-09-18PDF 568.9 KB
External PhotosExternal Photos2013-08-27PDF 115.3 KB
Label & LocationID Label/Location Info2013-08-27PDF 1.2 MB
Test Setup PhotosTest Setup Photos2013-09-18PDF 133.1 KB
Test ReportTest Report2013-09-18PDF 4.2 MB
Authorization LetterCover Letter(s)2013-09-18PDF 18.9 KB
Confidentiality LetterCover Letter(s)2013-09-18PDF 18.7 KB
Permissive Change Request LetterCover Letter(s)2013-09-18PDF 18.7 KB
Authorization LetterCover Letter(s)2013-08-27PDF 18.9 KB
Authorization Letter from Original ApplicantCover Letter(s)2013-08-27PDF 684.9 KB
Change of ID Request LetterCover Letter(s)2013-08-27PDF 18.7 KB
Confidentiality LetterCover Letter(s)2013-08-27PDF 21.6 KB
DTS-UNII Declaration LetterCover Letter(s)2013-08-27PDF 67.6 KB
RF ExposureRF Exposure Info2013-09-18PDF 85.4 KB

Application Information

Application IDgPaWktSQoAlBIv5hWrZ1KA==
Final Action Date2013-09-18
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0022066286
Model-SDMAN
Frequency Range5180-5320 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionSDIO Wireless Module
Responsible PartySteven Maulick, steve.maulick@stryker.com , 4087542000
Test FirmLeslie BAI, SIEMIC Labs, leslie.bai@siemic.com , 4085261188
TCB Emailtcb@siemic.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsC2PC for radio (FCC ID:SSH-SDMAN) to transmit simultaneous with SYNK Receiver radio inside the host unit (SYNK VisionPro 26'' Wireless LED Display, model: 0240031000). Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection.

Applications

Application IDDatePurpose
gPaWktSQoAlBIv5hWrZ1KA==2013-09-18Class II permissive change or modification of presently authorized equipment
dv2JlT9PqdxXEWKrHhtXFw==2013-09-18Class II permissive change or modification of presently authorized equipment
W8+1jMMZOvoPnvHrhEEyVQ==2013-09-18Class II permissive change or modification of presently authorized equipment
lLHgKzcmKJaXnUloIcxyoA==2013-08-27Change in identification of presently authorized equipment. Original FCC ID: N6C-SDMAN Grant Date: 08/20/2012
OhkD2izv7UOuW/RJVmqZSA==2013-08-27Change in identification of presently authorized equipment. Original FCC ID: N6C-SDMAN Grant Date: 05/16/2013
+1HKq59eoPIfQT7BIvy4kQ==2013-08-27Change in identification of presently authorized equipment. Original FCC ID: N6C-SDMAN Grant Date: 08/20/2012

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.008615CCC
2402-2480 MHz0.013900015CCC
2412-2462 MHz0.172315CCC
5180-5320 MHz0.024715ECC, ND
5500-5580 MHz0.01815ECC, ND
5660-5700 MHz0.0215ECC, ND
5745-5825 MHz0.19815CCC

Grants

TCB Grant - Application W8+1jMMZOvoPnvHrhEEyVQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Siemic Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 09/18/2013

Application Dated: 09/18/2013
Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Digital Transmission System
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0086  
CC 15C 2412.0  -  2462.0 0.1723  
CC 15C 5745.0  -  5825.0 0.198  

C2PC for radio (FCC ID:SSH-SDMAN) to transmit simultaneous with SYNK Receiver radio inside the host unit (SYNK VisionPro 26'' Wireless LED Display, model: 0240031000).

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application W8+1jMMZOvoPnvHrhEEyVQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
United States
  Date of Grant: 09/18/2013

Application Dated: 09/18/2013
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Digital Transmission System
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0086  
CC 15C 2412.0  -  2462.0 0.1723  
CC 15C 5745.0  -  5825.0 0.198  

C2PC for radio (FCC ID:SSH-SDMAN) to transmit simultaneous with SYNK Receiver radio inside the host unit (SYNK VisionPro 26'' Wireless LED Display, model: 0240031000).

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application OhkD2izv7UOuW/RJVmqZSA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Siemic Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 08/27/2013

Application Dated: 08/27/2013
Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC ND 15E 5180.0  -  5320.0 0.0247  
CC ND 15E 5500.0  -  5580.0 0.018  
CC ND 15E 5660.0  -  5700.0 0.02  

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection.

CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application OhkD2izv7UOuW/RJVmqZSA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
United States
  Date of Grant: 08/27/2013

Application Dated: 08/27/2013
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC ND 15E 5180.0  -  5320.0 0.0247  
CC ND 15E 5500.0  -  5580.0 0.018  
CC ND 15E 5660.0  -  5700.0 0.02  

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application lLHgKzcmKJaXnUloIcxyoA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Siemic Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 08/27/2013

Application Dated: 08/27/2013
Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0139  

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application lLHgKzcmKJaXnUloIcxyoA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
United States
  Date of Grant: 08/27/2013

Application Dated: 08/27/2013
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0139  

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application gPaWktSQoAlBIv5hWrZ1KA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Siemic Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 09/18/2013

Application Dated: 09/18/2013
Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC ND 15E 5180.0  -  5320.0 0.0247  
CC ND 15E 5500.0  -  5580.0 0.018  
CC ND 15E 5660.0  -  5700.0 0.02  

C2PC for radio (FCC ID:SSH-SDMAN) to transmit simultaneous with SYNK Receiver radio inside the host unit (SYNK VisionPro 26'' Wireless LED Display, model: 0240031000).

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application gPaWktSQoAlBIv5hWrZ1KA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
United States
  Date of Grant: 09/18/2013

Application Dated: 09/18/2013
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC ND 15E 5180.0  -  5320.0 0.0247  
CC ND 15E 5500.0  -  5580.0 0.018  
CC ND 15E 5660.0  -  5700.0 0.02  

C2PC for radio (FCC ID:SSH-SDMAN) to transmit simultaneous with SYNK Receiver radio inside the host unit (SYNK VisionPro 26'' Wireless LED Display, model: 0240031000).

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application dv2JlT9PqdxXEWKrHhtXFw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Siemic Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 09/18/2013

Application Dated: 09/18/2013
Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0139  

C2PC for radio (FCC ID:SSH-SDMAN) to transmit simultaneous with SYNK Receiver radio inside the host unit (SYNK VisionPro 26'' Wireless LED Display, model: 0240031000).

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application dv2JlT9PqdxXEWKrHhtXFw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
United States
  Date of Grant: 09/18/2013

Application Dated: 09/18/2013
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0139  

C2PC for radio (FCC ID:SSH-SDMAN) to transmit simultaneous with SYNK Receiver radio inside the host unit (SYNK VisionPro 26'' Wireless LED Display, model: 0240031000).

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application +1HKq59eoPIfQT7BIvy4kQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Siemic Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 08/27/2013

Application Dated: 08/27/2013
Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Digital Transmission System
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0086  
CC 15C 2412.0  -  2462.0 0.1723  
CC 15C 5745.0  -  5825.0 0.198  

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application +1HKq59eoPIfQT7BIvy4kQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
United States
  Date of Grant: 08/27/2013

Application Dated: 08/27/2013
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SDMAN
Name of Grantee:  Stryker Endoscopy
Equipment Class: Digital Transmission System
Notes: SDIO Wireless Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0086  
CC 15C 2412.0  -  2462.0 0.1723  
CC 15C 5745.0  -  5825.0 0.198  

Single Modular Approval. Output power listed is Conducted. Separate evaluation must be required for any portable configuration. When used in mobile applications, the antennas shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific information required to satisfy RF exposure compliance for the final host device. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. The antenna of this device must not be co-located or used in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: