FCC ID Device Details
| FCC ID | SSH-SYNK4KRX |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | SSH |
| Product Code | SYNK4KRX |
| Applicant Business | Stryker Endoscopy 🇺🇸 |
| Related Domains | |
| Equipment Class | SYNK 4K Wireless Receiver |
| Test Firm | Hyundai C-Tech, Inc. dba HCT America, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5755-5795 MHz | Class II permissive change or modification of presently authorized equipment | 2022-08-05 |
| 5190-5230 MHz | Original Equipment | 2020-09-29 |
| 5190-5230 MHz | Original Equipment | 2020-09-24 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2023-02-01 | PDF 2.1 MB |
| User Manual_20200902-182131_P43596_B - DRAFT for FCC submission | Users Manual | 2021-03-28 | PDF 1.7 MB |
| Internal Photos | Internal Photos | 2023-02-01 | PDF 653.1 KB |
| Internal Photos_20200902-182128_Internal Photo | Internal Photos | 2021-03-28 | PDF 245.1 KB |
| External Photos | External Photos | 2023-02-01 | PDF 644.4 KB |
| External Photos_20200902-182127_External Photo | External Photos | 2021-03-28 | PDF 242.3 KB |
| Label_20200902-182133_LF10533D | ID Label/Location Info | 2020-09-29 | PDF 811.4 KB |
| Test Setup Photo | Test Setup Photos | 2023-02-01 | PDF 782.1 KB |
| Test Setup Photos_20200902-182127_Setup Photo | Test Setup Photos | 2021-03-28 | PDF 604.6 KB |
| Antenna Spec | Test Report | 2022-08-05 | PDF 347.4 KB |
| Test Report_20200902-182106_FCC_IC_DFS_SL20060401-STR-006 Rev_1.0 | Test Report | 2020-09-29 | PDF 1,017.1 KB |
| Test Report_20200902-182108_FCC_IC_RF_SL20060401-STR-006 (Receiver) Rev_1.0 | Test Report | 2020-09-29 | PDF 813.6 KB |
| Test Report_20200902-182112_EMC101258A-FCC407 UNII 3 Rev. 5 (5755-5795) | Test Report | 2020-09-29 | PDF 1.3 MB |
| Test Report_20200902-182116_EMC101258A-FCC407 UNII 1 Rev. 6 (5190-5230) | Test Report | 2020-09-29 | PDF 1.4 MB |
| Test Report_20200902-182119_EMC101258A-FCC407 UNII 2 DFS Rev. 2 | Test Report | 2020-09-29 | PDF 1.4 MB |
| Test Report_20200902-182125_EMC101258A-FCC407 UNII 2 Rev. 5 (5270-5310 5510-5710 | Test Report | 2020-09-29 | PDF 2.4 MB |
| Agent Authorization Letter | Cover Letter(s) | 2022-08-05 | PDF 75.6 KB |
| C2PC Letter Metadata only | Cover Letter(s) | 2022-08-05 | PDF 98.8 KB |
| C2PC Letter R | Cover Letter(s) | 2022-08-05 | PDF 115.1 KB |
| Confidentiality Request Letter Metadata only | Cover Letter(s) | 2022-08-05 | PDF 80.1 KB |
| Confidentiality Request Letter R | Cover Letter(s) | 2022-08-05 | PDF 84.7 KB |
| Agency Agreement_20200902-182055_SCS-F18 Product Certification Representative Au | Cover Letter(s) | 2020-09-29 | PDF 94.3 KB |
| Confidentiality Request_20200902-182054_SCS-F19 Confidentiality Request Letter ( | Cover Letter(s) | 2020-09-29 | PDF 131 KB |
| Confidentiality Request_20200902-182055_SCS-F19 Confidentiality Request Letter ( | Cover Letter(s) | 2020-09-29 | PDF 132.1 KB |
| Cover Letter_20200902-182054_FCC Declaration Letter Leveraging Module Conducted | Cover Letter(s) | 2020-09-29 | PDF 107.6 KB |
| FCC_RF_SL20060401-STR-006_MPE (Receiver) Rev_2.0 | RF Exposure Info | 2020-09-29 | PDF 332.8 KB |
| RF Exposure Info_20200902-182105_FCC_RF_SL20060401-STR-006(Receiver)_MPE | RF Exposure Info | 2020-09-23 | PDF 468.6 KB |
| Block Diagram Metadata only | Block Diagram | PDF 65.2 KB | |
| Block Diagram_20200902-182056_SYNK 4K system block diagram Metadata only | Block Diagram | PDF 65.2 KB | |
| Block Diagram_20200902-182058_AMN42012_BlockDiagram_Confidential_r4 Metadata only | Block Diagram | PDF 410.7 KB | |
| Schematics_20200902-182057_AMN42012_B0_DRACO_RX_V2.2_r1_confidential Metadata only | Schematics | PDF 699.6 KB | |
| Schematics_20200902-182102_RX MSP11940 Rev C (1) Metadata only | Schematics | PDF 842.9 KB | |
| Operational Description Metadata only | Operational Description | PDF 122.2 KB | |
| Operational Description_20200902-182056_Synk 4k RX -- SOFTWARE SECURITY REQUIREM Metadata only | Operational Description | PDF 178.4 KB | |
| Operational Description_20200902-182059_Antenna spec 5400AT18A1000 Metadata only | Operational Description | PDF 347.4 KB | |
| Operational Description_20200902-182100_Product Specification Metadata only | Operational Description | PDF 596.2 KB | |
| Operational Description_20200902-182104_Synk 4k product description Metadata only | Operational Description | PDF 801.9 KB |
Application Information
| Application ID | VHvQK+VKCn+dc0sHjecTRg== |
|---|---|
| Final Action Date | 2022-08-05 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0016340077 |
| Model | SYNK4KRX |
| Frequency Range | 5755-5795 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | SYNK 4K Wireless Receiver |
| Responsible Party | Steven Maulick, steve.maulick@stryker.com |
| Test Firm | Timothy Choi, Hyundai C-Tech, Inc. dba HCT America, Inc., timothy.c@hctamerica.com |
| TCB Email | TCB@hctamerica.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 02/01/2023 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive Change to add 20 MHz Channel BW. Power listed is the maximum combined conducted output power. This device does not operate in MIMO mode. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| VHvQK+VKCn+dc0sHjecTRg== | 2022-08-05 | Class II permissive change or modification of presently authorized equipment |
| 0Vqt9Jc06ivjO6JCVx9aXw== | 2020-09-29 | Original Equipment |
| 6k/qdiNi/uuQCrZyX9K79g== | 2020-09-24 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules | Grant Notes |
|---|---|---|---|
| 5180-5240 MHz | 0.03673 | 15E | |
| 5190-5230 MHz | 0.11376 | 15E | MO |
| 5190-5230 MHz | 0.11376 | 15E | |
| 5260-5320 MHz | 0.03048 | 15E | ND |
| 5270-5310 MHz | 0.11429 | 15E | MO, ND |
| 5270-5310 MHz | 0.11429 | 15E | ND |
| 5500-5720 MHz | 0.03162 | 15E | ND |
| 5510-5710 MHz | 0.15276 | 15E | MO, ND |
| 5510-5710 MHz | 0.15276 | 15E | ND |
| 5740-5840 MHz | 0.02877 | 15E | |
| 5755-5795 MHz | 0.13335 | 15E | MO |
| 5755-5795 MHz | 0.13335 | 15E |
Grants
TCB Grant - Application VHvQK+VKCn+dc0sHjecTRg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
HCT America LLC 1726 Ringwood Avenue San Jose, CA 95131 |
Date of Grant: 08/05/2022 Application Dated: 08/05/2022 |
| Stryker Endoscopy |
| 5900 Optical Court |
| San Jose, CA 95138 |
| Attention: Steven Maulick |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SSH-SYNK4KRX |
| Name of Grantee: | Stryker Endoscopy |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | SYNK 4K Wireless Receiver |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15E | 5190.0 - 5230.0 | 0.11376 | |||
| ND | 15E | 5270.0 - 5310.0 | 0.11429 | ||
| ND | 15E | 5510.0 - 5710.0 | 0.15276 | ||
| 15E | 5755.0 - 5795.0 | 0.13335 | |||
| 15E | 5180.0 - 5240.0 | 0.03673 | |||
| ND | 15E | 5260.0 - 5320.0 | 0.03048 | ||
| ND | 15E | 5500.0 - 5720.0 | 0.03162 | ||
| 15E | 5740.0 - 5840.0 | 0.02877 |
| Class II Permissive Change to add 20 MHz Channel BW. Power listed is the maximum combined conducted output power. This device does not operate in MIMO mode. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application VHvQK+VKCn+dc0sHjecTRg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Stryker Endoscopy 5900 Optical Court San Jose, CA 95138 United States |
Date of Grant: 08/05/2022 Application Dated: 08/05/2022 |
| Attention: Steven Maulick |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SSH-SYNK4KRX |
| Name of Grantee: | Stryker Endoscopy |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | SYNK 4K Wireless Receiver |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15E | 5190.0 - 5230.0 | 0.11376 | |||
| ND | 15E | 5270.0 - 5310.0 | 0.11429 | ||
| ND | 15E | 5510.0 - 5710.0 | 0.15276 | ||
| 15E | 5755.0 - 5795.0 | 0.13335 | |||
| 15E | 5180.0 - 5240.0 | 0.03673 | |||
| ND | 15E | 5260.0 - 5320.0 | 0.03048 | ||
| ND | 15E | 5500.0 - 5720.0 | 0.03162 | ||
| 15E | 5740.0 - 5840.0 | 0.02877 |
| Class II Permissive Change to add 20 MHz Channel BW. Power listed is the maximum combined conducted output power. This device does not operate in MIMO mode. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bureau Veritas Consumer Products Services, Inc. 775 Montague Expressway Milpitas, CA 95035 |
Date of Grant: 09/29/2020 Application Dated: 09/25/2020 |
| Stryker Endoscopy |
| 5900 Optical Court |
| San Jose, CA 95138 |
| Attention: Steven Maulick |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SSH-SYNK4KRX |
| Name of Grantee: | Stryker Endoscopy |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | SYNK 4K Wireless Receiver |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15E | 5190.0 - 5230.0 | 0.11376 | ||
| MO ND | 15E | 5270.0 - 5310.0 | 0.11429 | ||
| MO ND | 15E | 5510.0 - 5710.0 | 0.15276 | ||
| MO | 15E | 5755.0 - 5795.0 | 0.13335 |
| Power listed is the maximum combined conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application 0Vqt9Jc06ivjO6JCVx9aXw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Stryker Endoscopy 5900 Optical Court San Jose, CA 95138 United States |
Date of Grant: 09/29/2020 Application Dated: 09/25/2020 |
| Attention: Steven Maulick |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SSH-SYNK4KRX |
| Name of Grantee: | Stryker Endoscopy |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | SYNK 4K Wireless Receiver |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15E | 5190.0 - 5230.0 | 0.11376 | ||
| MO ND | 15E | 5270.0 - 5310.0 | 0.11429 | ||
| MO ND | 15E | 5510.0 - 5710.0 | 0.15276 | ||
| MO | 15E | 5755.0 - 5795.0 | 0.13335 |
| Power listed is the maximum combined conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |