FCC ID SSH-SYNK4KTX

SYNK 4K Wireless Transmitter

by Stryker Endoscopy

Grantee Code: SSH   Product Code: SYNK4KTX
Latest application date: 2022-08-05

FCC ID Device Details

FCC IDSSH-SYNK4KTX
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSSH
Product CodeSYNK4KTX
Applicant BusinessStryker Endoscopy 🇺🇸
Related Domains stryker.com
Equipment ClassSYNK 4K Wireless Transmitter
Test FirmHyundai C-Tech, Inc. dba HCT America, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5755-5795 MHzClass II permissive change or modification of presently authorized equipment2022-08-05
5190-5230 MHzOriginal Equipment2020-09-23

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2023-02-01PDF 2.1 MB
User Manual_20200901-185720_P43596_B - DRAFT for FCC submissionUsers Manual2021-03-22PDF 1.7 MB
Internal PhotosInternal Photos2023-02-01PDF 711.4 KB
Internal Photos Metadata onlyInternal Photos2021-03-22PDF 245.1 KB
Internal Photos_20200901-185719_Internal PhotoInternal Photos2021-03-22PDF 245.1 KB
External PhotosExternal Photos2023-02-01PDF 625.7 KB
External Photos Metadata onlyExternal Photos2021-03-22PDF 242.3 KB
External Photos_20200901-185721_External PhotoExternal Photos2021-03-22PDF 242.3 KB
Label_20200901-185722_LF10533DID Label/Location Info2020-09-23PDF 811.4 KB
Product labels Metadata onlyID Label/Location Info2020-09-23PDF 811.4 KB
Test Setup PhotoTest Setup Photos2023-02-01PDF 774.7 KB
Test Setup Photos_20200901-185721_Setup PhotoTest Setup Photos2021-03-22PDF 604.6 KB
Antenna SpecTest Report2022-08-05PDF 347.4 KB
NII Test ReportTest Report2022-08-05PDF 3.9 MB
Test Report_20200901-185712_FCC_IC_RF_SL20060401-STR-006 (Transmitter)_Rev_2.0Test Report2020-09-23PDF 1.1 MB
Test Report_20200901-185714_EMC101258B-FCC407 UNII 3 Rev. 6 (5755-5795)Test Report2020-09-23PDF 1.3 MB
Test Report_20200901-185715_EMC101258B-FCC407 UNII 1 Rev. 6 (5190-5230)Test Report2020-09-23PDF 1.6 MB
Test Report_20200901-185716_EMC101258B-FCC407 UNII 2 DFS Rev. 3Test Report2020-09-23PDF 1.3 MB
Test Report_20200901-185719_EMC101258B-FCC407 UNII 2 Rev. 5 (5270-5310 5510-5710Test Report2020-09-23PDF 3.1 MB
Declaration Letter Leveraging Module Metadata onlyAttestation Statements2020-09-23PDF 109 KB
Agent Authorization LetterCover Letter(s)2022-08-05PDF 107.2 KB
C2PC LetterCover Letter(s)2022-08-05PDF 171.3 KB
Confidentiality Request LetterCover Letter(s)2022-08-05PDF 113.5 KB
Agency Agreement_20200901-185704_SCS-F18 Product Certification Representative AuCover Letter(s)2020-09-23PDF 104.8 KB
Confidentiality Request Letter LTC Metadata onlyCover Letter(s)2020-09-23PDF 143.9 KB
Confidentiality Request Letter STC Metadata onlyCover Letter(s)2020-09-23PDF 144 KB
Confidentiality Request_20200901-185704_SCS-F19 Confidentiality Request Letter (Cover Letter(s)2020-09-23PDF 143.9 KB
Confidentiality Request_20200901-185705_SCS-F19 Confidentiality Request Letter (Cover Letter(s)2020-09-23PDF 144 KB
Cover Letter_20200901-185705_FCC Declaration Letter Leveraging Module ConductedCover Letter(s)2020-09-23PDF 109 KB
Product Certification Representative Auth Letter Metadata onlyCover Letter(s)2020-09-23PDF 104.8 KB
RF Exposure ReportRF Exposure Info2022-08-05PDF 497.8 KB
FCC_RF_SL20060401-STR-006_MPE (Transmitter) Rev_2.0RF Exposure Info2020-09-23PDF 267.9 KB
MPE Report Metadata onlyRF Exposure Info2020-09-23PDF 267.9 KB
AMN41012 Block Diagram Metadata onlyBlock DiagramPDF 406.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 65.2 KB
Block Diagram_20200901-185707_SYNK 4K system block diagram Metadata onlyBlock DiagramPDF 65.2 KB
Block Diagram_20200901-185710_AMN41012_BlockDiagram_Confidential_r2 Metadata onlyBlock DiagramPDF 406.3 KB
SYNK 4K system block diagram Metadata onlyBlock DiagramPDF 65.2 KB
Schematics_20200901-185709_TX_MSP11936 Rev C (2) Metadata onlySchematicsPDF 934.7 KB
Schematics_20200901-185710_AMN41012_B0_Draco_TX_V2.3_r1_Confidential Metadata onlySchematicsPDF 637.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 122.2 KB
Operational Description_20200901-185705_Product Specification Metadata onlyOperational DescriptionPDF 596.2 KB
Operational Description_20200901-185706_Synk 4k product description Metadata onlyOperational DescriptionPDF 801.9 KB
Operational Description_20200901-185708_Synk 4k TX -- SOFTWARE SECURITY REQUIREM Metadata onlyOperational DescriptionPDF 178.4 KB
Product Description Metadata onlyOperational DescriptionPDF 596.2 KB
Product Specification Metadata onlyOperational DescriptionPDF 801.9 KB
Software Security Declaration Metadata onlyOperational DescriptionPDF 178.4 KB

Application Information

Application IDqq3q4b4lutrRlVpV6ovnRQ==
Final Action Date2022-08-05
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0016340077
ModelSYNK4KTX
Frequency Range5755-5795 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionSYNK 4K Wireless Transmitter
Responsible PartySteven Maulick, steve.maulick@stryker.com , 4087542000
Test FirmTimothy Choi, Hyundai C-Tech, Inc. dba HCT America, Inc., timothy.c@hctamerica.com , 510-933-8848
TCB EmailTCB@hctamerica.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date02/01/2023
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsClass II Permissive Change to add 20MHz BW operation to existing 40MHz BW performance. Power listed is the maximum combined conducted power. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile configuration only. Device is a client device has 4X4 MIMO capability. Only those antennas tested with the device may be used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
qq3q4b4lutrRlVpV6ovnRQ==2022-08-05Class II permissive change or modification of presently authorized equipment
S97X4x+m4AdOVBraltieDg==2020-09-23Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
5180-5240 MHz0.053515EMO
5190-5230 MHz0.24315EMO
5260-5320 MHz0.050215EMO, ND
5270-5310 MHz0.2515EMO, ND
5500-5720 MHz0.058215EMO, ND
5510-5710 MHz0.24415EMO, ND
5740-5840 MHz0.053515EMO
5755-5795 MHz0.72415EMO

Grants

TCB Grant - Application S97X4x+m4AdOVBraltieDg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 09/23/2020

Application Dated: 09/23/2020
Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SYNK4KTX
Name of Grantee:  Stryker Endoscopy
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: SYNK 4K Wireless Transmitter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15E 5190.0  -  5230.0 0.243  
MO ND 15E 5270.0  -  5310.0 0.25  
MO ND 15E 5510.0  -  5710.0 0.244  
MO 15E 5755.0  -  5795.0 0.724  

Power listed is the maximum combined conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application S97X4x+m4AdOVBraltieDg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
United States
  Date of Grant: 09/23/2020

Application Dated: 09/23/2020
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SYNK4KTX
Name of Grantee:  Stryker Endoscopy
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: SYNK 4K Wireless Transmitter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15E 5190.0  -  5230.0 0.243  
MO ND 15E 5270.0  -  5310.0 0.25  
MO ND 15E 5510.0  -  5710.0 0.244  
MO 15E 5755.0  -  5795.0 0.724  

Power listed is the maximum combined conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application qq3q4b4lutrRlVpV6ovnRQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  HCT America LLC
1726 Ringwood Avenue
San Jose, CA 95131
Date of Grant: 08/05/2022

Application Dated: 08/05/2022
Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SYNK4KTX
Name of Grantee:  Stryker Endoscopy
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: SYNK 4K Wireless Transmitter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15E 5190.0  -  5230.0 0.243  
MO ND 15E 5270.0  -  5310.0 0.25  
MO ND 15E 5510.0  -  5710.0 0.244  
MO 15E 5755.0  -  5795.0 0.724  
MO 15E 5180.0  -  5240.0 0.0535  
MO ND 15E 5260.0  -  5320.0 0.0502  
MO ND 15E 5500.0  -  5720.0 0.0582  
MO 15E 5740.0  -  5840.0 0.0535  

Class II Permissive Change to add 20MHz BW operation to existing 40MHz BW performance. Power listed is the maximum combined conducted power. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile configuration only. Device is a client device has 4X4 MIMO capability. Only those antennas tested with the device may be used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application qq3q4b4lutrRlVpV6ovnRQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
United States
  Date of Grant: 08/05/2022

Application Dated: 08/05/2022
 
Attention: Steven Maulick

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SSH-SYNK4KTX
Name of Grantee:  Stryker Endoscopy
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: SYNK 4K Wireless Transmitter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15E 5190.0  -  5230.0 0.243  
MO ND 15E 5270.0  -  5310.0 0.25  
MO ND 15E 5510.0  -  5710.0 0.244  
MO 15E 5755.0  -  5795.0 0.724  
MO 15E 5180.0  -  5240.0 0.0535  
MO ND 15E 5260.0  -  5320.0 0.0502  
MO ND 15E 5500.0  -  5720.0 0.0582  
MO 15E 5740.0  -  5840.0 0.0535  

Class II Permissive Change to add 20MHz BW operation to existing 40MHz BW performance. Power listed is the maximum combined conducted power. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This module is approved in mobile configuration only. Device is a client device has 4X4 MIMO capability. Only those antennas tested with the device may be used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. End users must be provided with transmitter operating conditions for satisfying RF exposure compliance.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).