FCC ID SSH-SYNKTX
SYNK Wireless Transmitter
by Stryker Endoscopy
Grantee Code: SSH Product Code: SYNKTX
Latest application date: 2014-01-20
FCC ID Device Details
| FCC ID | SSH-SYNKTX |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | SSH |
| Product Code | SYNKTX |
| Applicant Business | Stryker Endoscopy 🇺🇸 |
| Related Domains | |
| Equipment Class | SYNK Wireless Transmitter |
| Test Firm | SIEMIC Labs |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2014-01-20 |
| 5745-5825 MHz | Original Equipment | 2014-01-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2014-07-19 | PDF 192.9 KB |
| Internal Photos | Internal Photos | 2014-01-20 | PDF 288.5 KB |
| External Photos | External Photos | 2014-01-20 | PDF 288.5 KB |
| Label | ID Label/Location Info | 2014-01-20 | PDF 609.6 KB |
| Label Location | ID Label/Location Info | 2014-01-20 | PDF 205 KB |
| Test Setup Photos | Test Setup Photos | 2014-01-20 | PDF 141 KB |
| DFS Client Report - Part 1 | Test Report | 2014-01-20 | PDF 799 KB |
| DFS Client Report - Part 2 | Test Report | 2014-01-20 | PDF 4.8 MB |
| Test Report | Test Report | 2014-01-20 | PDF 5.2 MB |
| Test Report | Test Report | 2014-01-20 | PDF 4.8 MB |
| DTS-UNII Declaration Letter | Attestation Statements | 2014-01-20 | PDF 69.1 KB |
| Modular Approval Letter | Attestation Statements | 2014-01-20 | PDF 28 KB |
| Authorization Letter | Cover Letter(s) | 2014-01-20 | PDF 18.9 KB |
| Authrization Letter | Cover Letter(s) | 2014-01-20 | PDF 18.9 KB |
| Confidentiality Letter | Cover Letter(s) | 2014-01-20 | PDF 25.5 KB |
| MPE Calculation | RF Exposure Info | 2014-01-20 | PDF 85.2 KB |
| MPE Calculation | RF Exposure Info | 2014-01-20 | PDF 82.6 KB |
Application Information
| Application ID | lSgljHUJ6gBKucL+QnQQYg== |
|---|---|
| Final Action Date | 2014-01-20 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0022066286 |
| Model | -SYNKTX |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | SYNK Wireless Transmitter |
| Responsible Party | Steven Maulick, steve.maulick@stryker.com |
| Test Firm | Leslie BAI, SIEMIC Labs, leslie.bai@siemic.com |
| TCB Email | tcb@siemic.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 07/19/2014 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Limited Single Modular Approval |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | LMA for mobile platform host Power listed is combined conducted RF power. Device is operated with only 20MHz ,4X1 Spatial Multiplexing MIMO configuration as described in this filing This transmitter is restricted to indoor use in the 5150MHz to 5250MHz frequency range. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter as otherwise documented in the filing. and End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| lSgljHUJ6gBKucL+QnQQYg== | 2014-01-20 | Original Equipment |
| 149gqWWqp4bceGv4Oaa4BQ== | 2014-01-20 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application lSgljHUJ6gBKucL+QnQQYg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Siemic Inc. 775 Montague Expressway Milpitas, CA 95035 |
Date of Grant: 01/20/2014 Application Dated: 01/20/2014 |
| Stryker Endoscopy |
| 5900 Optical Court |
| San Jose, CA 95138 |
| Attention: Steven Maulick |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SSH-SYNKTX |
| Name of Grantee: | Stryker Endoscopy |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | SYNK Wireless Transmitter |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC ND | 15E | 5180.0 - 5240.0 | 0.029 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0297 | ||
| CC ND | 15E | 5500.0 - 5580.0 | 0.0316 | ||
| CC ND | 15E | 5660.0 - 5700.0 | 0.0316 |
| LMA for mobile platform host Power listed is combined conducted RF power. Device is operated with only 20MHz ,4X1 Spatial Multiplexing MIMO configuration as described in this filing This transmitter is restricted to indoor use in the 5150MHz to 5250MHz frequency range. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter as otherwise documented in the filing. and End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application lSgljHUJ6gBKucL+QnQQYg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Stryker Endoscopy 5900 Optical Court San Jose, CA 95138 United States |
Date of Grant: 01/20/2014 Application Dated: 01/20/2014 |
| Attention: Steven Maulick |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SSH-SYNKTX |
| Name of Grantee: | Stryker Endoscopy |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | SYNK Wireless Transmitter |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC ND | 15E | 5180.0 - 5240.0 | 0.029 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0297 | ||
| CC ND | 15E | 5500.0 - 5580.0 | 0.0316 | ||
| CC ND | 15E | 5660.0 - 5700.0 | 0.0316 |
| LMA for mobile platform host Power listed is combined conducted RF power. Device is operated with only 20MHz ,4X1 Spatial Multiplexing MIMO configuration as described in this filing This transmitter is restricted to indoor use in the 5150MHz to 5250MHz frequency range. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter as otherwise documented in the filing. and End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Siemic Inc. 775 Montague Expressway Milpitas, CA 95035 |
Date of Grant: 01/20/2014 Application Dated: 01/20/2014 |
| Stryker Endoscopy |
| 5900 Optical Court |
| San Jose, CA 95138 |
| Attention: Steven Maulick |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SSH-SYNKTX |
| Name of Grantee: | Stryker Endoscopy |
| Equipment Class: | Digital Transmission System |
| Notes: | SYNK Wireless Transmitter |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 5745.0 - 5825.0 | 0.0218 |
| LMA for mobile platform host Power listed is combined conducted RF power. Device is operated with only 20MHz ,4X1 Spatial Multiplexing MIMO configuration as described in this filing The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter as otherwise documented in the filing. and End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application 149gqWWqp4bceGv4Oaa4BQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Stryker Endoscopy 5900 Optical Court San Jose, CA 95138 United States |
Date of Grant: 01/20/2014 Application Dated: 01/20/2014 |
| Attention: Steven Maulick |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SSH-SYNKTX |
| Name of Grantee: | Stryker Endoscopy |
| Equipment Class: | Digital Transmission System |
| Notes: | SYNK Wireless Transmitter |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 5745.0 - 5825.0 | 0.0218 |
| LMA for mobile platform host Power listed is combined conducted RF power. Device is operated with only 20MHz ,4X1 Spatial Multiplexing MIMO configuration as described in this filing The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter as otherwise documented in the filing. and End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |