FCC ID STJ80411396001
Wireless USB Adapter
by ICU Medical, Inc.
Grantee Code: STJ Product Code: 80411396001
Latest application date: 2019-04-12
FCC ID Device Details
| FCC ID | STJ80411396001 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | STJ |
| Product Code | 80411396001 |
| Applicant Business | ICU Medical, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | Wireless USB Adapter |
| Test Firm | National Technical Systems |
Linked Records
Barcode records decoded from published FCC label exhibits or linked by an explicit FCC ID reference on a product page.
| UPC / GTIN | Linked product |
|---|---|
| 12391042067904 GTIN-14 | Wireless USB Adapter Brand: Hospira, Inc. · Model: 80411396001 Source: FCC label |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2019-04-12 |
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2016-06-07 |
| 2412-2462 MHz | Class II permissive change or modification of presently authorized equipment | 2007-07-30 |
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2007-07-30 |
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2007-06-27 |
| 2412-2462 MHz | Class II permissive change or modification of presently authorized equipment | 2007-06-27 |
| 2412-2462 MHz | Class II permissive change or modification of presently authorized equipment | 2007-05-10 |
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2007-05-10 |
| 2412-2462 MHz | Class II permissive change or modification of presently authorized equipment | 2007-03-19 |
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2007-03-19 |
| 2412-2462 MHz | Change in identification of presently authorized equipment. Original FCC ID: KA2DWLAG132A1 Grant Date: 03/25/2005 | 2007-03-12 |
| 5150-5350 MHz | Change in identification of presently authorized equipment. Original FCC ID: KA2DWLAG132A1 Grant Date: 03/25/2005 | 2007-03-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Manual | Users Manual | 2007-07-30 | PDF 329.3 KB |
| User Manual | Users Manual | 2007-07-30 | PDF 329.3 KB |
| Manual | Users Manual | 2007-06-27 | PDF 1.2 MB |
| User Manual | Users Manual | 2007-06-27 | PDF 1.2 MB |
| Manual | Users Manual | 2007-05-10 | PDF 2.1 MB |
| User Manual | Users Manual | 2007-05-10 | PDF 2.1 MB |
| User Manual | Users Manual | 2007-03-19 | PDF 3.6 MB |
| Internal Photos | Internal Photos | 2007-03-19 | PDF 452.3 KB |
| Host Photos | External Photos | 2007-07-30 | PDF 136.2 KB |
| Antenna Photos | External Photos | 2007-06-27 | PDF 211.6 KB |
| Antenna photos | External Photos | 2007-06-27 | PDF 211.6 KB |
| Host Photos | External Photos | 2007-06-27 | PDF 362.6 KB |
| Host photos | External Photos | 2007-06-27 | PDF 362.6 KB |
| Host Photos | External Photos | 2007-05-10 | PDF 205.2 KB |
| External Photos | External Photos | 2007-03-19 | PDF 191.4 KB |
| External Photos | External Photos | 2007-03-12 | PDF 534.2 KB |
| Label | ID Label/Location Info | 2007-06-27 | PDF 327.4 KB |
| FCC ID Label | ID Label/Location Info | 2007-05-10 | PDF 354.1 KB |
| Host Label | ID Label/Location Info | 2007-05-10 | PDF 354.1 KB |
| FCC ID Label | ID Label/Location Info | 2007-03-19 | PDF 454.8 KB |
| FCC ID Label | ID Label/Location Info | 2007-03-12 | PDF 479.9 KB |
| Test Setup Photos | Test Setup Photos | 2019-04-12 | PDF 179.3 KB |
| Setup Photos | Test Setup Photos | 2007-06-27 | PDF 231.6 KB |
| Setup Photos | Test Setup Photos | 2007-06-27 | PDF 228 KB |
| Setup Photos | Test Setup Photos | 2007-05-10 | PDF 134.8 KB |
| Setup Photos | Test Setup Photos | 2007-05-10 | PDF 134.8 KB |
| Setup Photos | Test Setup Photos | 2007-03-19 | PDF 236.4 KB |
| Setup Photos | Test Setup Photos | 2007-03-19 | PDF 221.2 KB |
| Test Report | Test Report | 2019-04-12 | PDF 560.4 KB |
| UNII-3 Attestation | Test Report | 2016-06-07 | PDF 108.8 KB |
| Report | Test Report | 2007-06-27 | PDF 578.3 KB |
| Report | Test Report | 2007-06-27 | PDF 649.5 KB |
| Test Report | Test Report | 2007-05-10 | PDF 620 KB |
| Test Report | Test Report | 2007-05-10 | PDF 583.8 KB |
| Test Report | Test Report | 2007-03-19 | PDF 1.9 MB |
| Test Report | Test Report | 2007-03-19 | PDF 1.2 MB |
| Turbo Mode Attestation letter | Cover Letter(s) | 2007-03-19 | PDF 140.9 KB |
| Agent Authorization | Cover Letter(s) | 2019-04-12 | PDF 461.4 KB |
| Cover Letter | Cover Letter(s) | 2019-04-12 | PDF 24.7 KB |
| Auth Ltr | Cover Letter(s) | 2016-06-07 | PDF 157.1 KB |
| Confid Ltr | Cover Letter(s) | 2016-06-07 | PDF 299.1 KB |
| Cvr Ltr | Cover Letter(s) | 2016-06-07 | PDF 26.7 KB |
| Authorization Letter | Cover Letter(s) | 2007-07-30 | PDF 534.3 KB |
| Class II Permissive Change Letter | Cover Letter(s) | 2007-07-30 | PDF 65 KB |
| Class II Permissive Change Letter | Cover Letter(s) | 2007-06-27 | PDF 181.8 KB |
| TCB Q and A | Cover Letter(s) | 2007-06-27 | PDF 17.4 KB |
| Class II Permissive Change Letter | Cover Letter(s) | 2007-05-10 | PDF 72.4 KB |
| Adhoc Mode Attestaton letter | Cover Letter(s) | 2007-03-19 | PDF 145.5 KB |
| Class II Permissive Change Letter | Cover Letter(s) | 2007-03-19 | PDF 170.9 KB |
| Request for Confidentiality | Cover Letter(s) | 2007-03-19 | PDF 195.3 KB |
| D Link Authorization Letter | Cover Letter(s) | 2007-03-12 | PDF 20.6 KB |
| Hospira Request Letter | Cover Letter(s) | 2007-03-12 | PDF 238.8 KB |
| Antennan | Parts List/Tune Up Info | 2007-07-30 | PDF 58.4 KB |
| SAR Report | RF Exposure Info | 2007-07-30 | PDF 562 KB |
| SAR attachment 1 | RF Exposure Info | 2007-07-30 | PDF 548.3 KB |
| SAR attachment 2 | RF Exposure Info | 2007-07-30 | PDF 953.8 KB |
| SAR attachment 3 | RF Exposure Info | 2007-07-30 | PDF 673.9 KB |
| SAR attachment 4 | RF Exposure Info | 2007-07-30 | PDF 688.2 KB |
| SAR attachment 5 | RF Exposure Info | 2007-07-30 | PDF 790.3 KB |
| SAR Report | RF Exposure Info | 2007-06-27 | PDF 576.6 KB |
| SAR attachment 1 | RF Exposure Info | 2007-06-27 | PDF 593.2 KB |
| SAR attachment 2 | RF Exposure Info | 2007-06-27 | PDF 1.4 MB |
| SAR attachment 3 | RF Exposure Info | 2007-06-27 | PDF 1.1 MB |
| SAR attachment 4 | RF Exposure Info | 2007-06-27 | PDF 535.8 KB |
| SAR Report | RF Exposure Info | 2007-05-10 | PDF 540.4 KB |
| SAR attachment 1 | RF Exposure Info | 2007-05-10 | PDF 545.3 KB |
| SAR attachment 2 1 | RF Exposure Info | 2007-05-10 | PDF 288.8 KB |
| SAR attachment 2 2 | RF Exposure Info | 2007-05-10 | PDF 275.5 KB |
| SAR Report | RF Exposure Info | 2007-03-19 | PDF 1.1 MB |
| SAR attachment 1 | RF Exposure Info | 2007-03-19 | PDF 598.6 KB |
| SAR attachment 2 2 | RF Exposure Info | 2007-03-19 | PDF 1.6 MB |
| SAR attachment 2 1 | RF Exposure Info | 2007-03-19 | PDF 748.5 KB |
| NII Security Metadata only | SDR Software/Security Inf | PDF 45.7 KB |
Application Information
| Application ID | I6EObjnG5dR/Jru4Asd6kQ== |
|---|---|
| Final Action Date | 2019-04-12 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0012322509 |
| Model | 80411396001 |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Wireless USB Adapter |
| Responsible Party | Chaitanya M Srinivasamurthy, Section Manager, chaitanya.srinivasamurthy@icumed.com |
| Agent | David David David, National Technical Systems, svdoc@nts.com |
| Technical Contact | David Bare, National Technical Systems, svdoc@nts.com |
| Test Firm | David Bare, National Technical Systems, david.bare@nts.com |
| TCB Email | svtcb@nts.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. Highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in all Infusion Pump configurations are: 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. Class II Permissive Change to update UNII-3 band. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| I6EObjnG5dR/Jru4Asd6kQ== | 2019-04-12 | Class II permissive change or modification of presently authorized equipment |
| SBGDO1UvcOSJZg8zVf7GpQ== | 2016-06-07 | Class II permissive change or modification of presently authorized equipment |
| czcLZ/NSvKve/wwqNhdGMA== | 2007-07-30 | Class II permissive change or modification of presently authorized equipment |
| 2zWYbsAm+0qVe2QDjlMTew== | 2007-07-30 | Class II permissive change or modification of presently authorized equipment |
| b12sNsL/yOWSK+U+l7Xm5g== | 2007-06-27 | Class II permissive change or modification of presently authorized equipment |
| H1roSP9igoAIXgjl7PtDpA== | 2007-06-27 | Class II permissive change or modification of presently authorized equipment |
| yAPMxWFN3qWeGU6s4YE8ZA== | 2007-05-10 | Class II permissive change or modification of presently authorized equipment |
| F0EyXzFM0KzzP2oL04PTJw== | 2007-05-10 | Class II permissive change or modification of presently authorized equipment |
| cC9j+2eEQRDtHj2Ua0JRDw== | 2007-03-19 | Class II permissive change or modification of presently authorized equipment |
| YNphHOwYM/0Z/9czxfixYg== | 2007-03-19 | Class II permissive change or modification of presently authorized equipment |
| qdzME5qWd2mweK1AfrzCLg== | 2007-03-12 | Change in identification of presently authorized equipment. Original FCC ID: KA2DWLAG132A1 Grant Date: 03/25/2005 |
| Qal9kaXzTyHxc2kipBl3WA== | 2007-03-12 | Change in identification of presently authorized equipment. Original FCC ID: KA2DWLAG132A1 Grant Date: 03/25/2005 |
Equipment Authorization
| Frequency | Output | Rules | Grant Notes |
|---|---|---|---|
| 2412-2462 MHz | 0.052 | 15C | CC |
| 2412-2462 MHz | 0.052 | 15C | |
| 5150-5350 MHz | 0.0410000 | 15E | |
| 5180-5240 MHz | 0.04 | 15E | CC |
| 5180-5240 MHz | 0.04 | 15E | 38, CC |
| 5260-5320 MHz | 0.04 | 15E | CC |
| 5260-5320 MHz | 0.04 | 15E | 38, CC |
| 5260-5320 MHz | 0.04 | 15E | CC, ND |
| 5500-5700 MHz | 0.049 | 15E | CC |
| 5500-5700 MHz | 0.049 | 15E | 38, CC |
| 5500-5700 MHz | 0.049 | 15E | CC, ND |
| 5725-5825 MHz | 0.041 | 15C | CC |
| 5725-5850 MHz | 0.041 | 15C | |
| 5745-5825 MHz | 0.041 | 15E | CC |
| 5745-5825 MHz | 0.041 | 15E | 49, CC |
Grants
TCB Grant - Application YNphHOwYM/0Z/9czxfixYg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 | Date of Grant: 03/19/2007 Application Dated: 03/19/2007 |
| Hospira, Inc. |
| 755 Jarvis Drive |
| Morgan Hill, CA 95037 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.04 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.049 |
| Class II Permissive Change to activate the 5.47-5.725GHz band and include a specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configuration 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application YNphHOwYM/0Z/9czxfixYg==
| COPY | FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION | COPY |
| Certification |
| Hospira, Inc. 755 Jarvis Drive Morgan Hill, CA 95037 United States | Date of Grant: 03/19/2007 Application Dated: 03/19/2007 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.04 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.049 |
| Class II Permissive Change to activate the 5.47-5.725GHz band and include a specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configuration 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band.
|
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: |
| EA417965 |
TCB Grant - Application yAPMxWFN3qWeGU6s4YE8ZA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 | Date of Grant: 05/10/2007 Application Dated: 05/10/2007 |
| Hospira, Inc. |
| 755 Jarvis Drive |
| Morgan Hill, CA 95037 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.052 | ||
| CC | 15C | 5725.0 - 5825.0 | 0.041 |
| Class II Permissive Change to include specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configuration 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application yAPMxWFN3qWeGU6s4YE8ZA==
| COPY | FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION | COPY |
| Certification |
| Hospira, Inc. 755 Jarvis Drive Morgan Hill, CA 95037 United States | Date of Grant: 05/10/2007 Application Dated: 05/10/2007 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.052 | ||
| CC | 15C | 5725.0 - 5825.0 | 0.041 |
| Class II Permissive Change to include specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configuration 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band.
|
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |
| EA970195 |
TCB Grant - Application SBGDO1UvcOSJZg8zVf7GpQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
National Technical Systems 41039 Boyce Road Fremont, CA 94538 |
Date of Grant: 06/07/2016 Application Dated: 06/07/2016 |
| ICU Medical, Inc. |
| 951 Calle Amanecer |
| San Clemente, CA 92673 |
| Attention: Chaitanya Srinivasamurthy , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | ICU Medical, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| 38 CC | 15E | 5260.0 - 5320.0 | 0.04 | ||
| 38 CC | 15E | 5500.0 - 5700.0 | 0.049 | ||
| 49 CC | 15E | 5745.0 - 5825.0 | 0.041 |
| Output power is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. Highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in all Infusion Pump configurations are: 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. Class II Permissive Change to update UNII-3 band. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| 49: | The device has been approved under § 15.407(b)(4)(ii) for antenna gains of 10 dBi or less and cannot be manufactured, marketed, sold or imported after March 2, 2020. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application SBGDO1UvcOSJZg8zVf7GpQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ICU Medical, Inc. 951 Calle Amanecer San Clemente, CA 92673 United States |
Date of Grant: 06/07/2016 Application Dated: 06/07/2016 |
| Attention: Chaitanya Srinivasamurthy , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | ICU Medical, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| 38 CC | 15E | 5260.0 - 5320.0 | 0.04 | ||
| 38 CC | 15E | 5500.0 - 5700.0 | 0.049 | ||
| 49 CC | 15E | 5745.0 - 5825.0 | 0.041 |
| Output power is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. Highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in all Infusion Pump configurations are: 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. Class II Permissive Change to update UNII-3 band. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| 49: | The device has been approved under § 15.407(b)(4)(ii) for antenna gains of 10 dBi or less and cannot be manufactured, marketed, sold or imported after March 2, 2020. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 | Date of Grant: 03/12/2007 Application Dated: 03/12/2007 |
| Hospira, Inc. |
| 755 Jarvis Drive |
| Morgan Hill, CA 95037 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.052 | |||
| 15C | 5725.0 - 5850.0 | 0.041 |
| Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. |
EAS Grant - Application qdzME5qWd2mweK1AfrzCLg==
| COPY | FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION | COPY |
| Certification |
| Hospira, Inc. 755 Jarvis Drive Morgan Hill, CA 95037 United States | Date of Grant: 03/12/2007 Application Dated: 03/12/2007 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.052 | |||
| 15C | 5725.0 - 5850.0 | 0.041 |
| Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band.
|
| Mail To: |
| EA961070 |
TCB Grant - Application Qal9kaXzTyHxc2kipBl3WA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 | Date of Grant: 03/12/2007 Application Dated: 03/12/2007 |
| Hospira, Inc. |
| 755 Jarvis Drive |
| Morgan Hill, CA 95037 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15E | 5150.0 - 5350.0 | 0.041 |
| Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. |
EAS Grant - Application Qal9kaXzTyHxc2kipBl3WA==
| COPY | FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION | COPY |
| Certification |
| Hospira, Inc. 755 Jarvis Drive Morgan Hill, CA 95037 United States | Date of Grant: 03/12/2007 Application Dated: 03/12/2007 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15E | 5150.0 - 5350.0 | 0.041 |
| Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band.
|
| Mail To: |
| EA631396 |
TCB Grant - Application I6EObjnG5dR/Jru4Asd6kQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
National Technical Systems 41039 Boyce Road Fremont, CA 94538 |
Date of Grant: 04/12/2019 Application Dated: 04/12/2019 |
| ICU Medical, Inc. |
| 951 Calle Amanecer |
| San Clemente, CA 92673 |
| Attention: Chaitanya Srinivasamurthy , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | ICU Medical, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| CC | 15E | 5260.0 - 5320.0 | 0.04 | ||
| CC | 15E | 5500.0 - 5700.0 | 0.049 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.041 |
| Output power is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. Highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in all Infusion Pump configurations are: 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. Class II Permissive Change to update UNII-3 band. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application I6EObjnG5dR/Jru4Asd6kQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
ICU Medical, Inc. 951 Calle Amanecer San Clemente, CA 92673 United States |
Date of Grant: 04/12/2019 Application Dated: 04/12/2019 |
| Attention: Chaitanya Srinivasamurthy , Section Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | ICU Medical, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| CC | 15E | 5260.0 - 5320.0 | 0.04 | ||
| CC | 15E | 5500.0 - 5700.0 | 0.049 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.041 |
| Output power is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. Highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in all Infusion Pump configurations are: 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. Class II Permissive Change to update UNII-3 band. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 | Date of Grant: 06/27/2007 Application Dated: 06/27/2007 |
| Hospira, Inc. |
| 755 Jarvis Drive |
| Morgan Hill, CA 95037 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.052 | ||
| CC | 15C | 5725.0 - 5825.0 | 0.041 |
| Class II Permissive Change to include specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configuration 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application H1roSP9igoAIXgjl7PtDpA==
| COPY | FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION | COPY |
| Certification |
| Hospira, Inc. 755 Jarvis Drive Morgan Hill, CA 95037 United States | Date of Grant: 06/27/2007 Application Dated: 06/27/2007 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.052 | ||
| CC | 15C | 5725.0 - 5825.0 | 0.041 |
| Class II Permissive Change to include specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configuration 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band.
|
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |
| EA285866 |
TCB Grant - Application F0EyXzFM0KzzP2oL04PTJw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 | Date of Grant: 05/10/2007 Application Dated: 05/10/2007 |
| Hospira, Inc. |
| 755 Jarvis Drive |
| Morgan Hill, CA 95037 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.04 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.049 |
| Class II Permissive Change to include specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configuration 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application F0EyXzFM0KzzP2oL04PTJw==
| COPY | FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION | COPY |
| Certification |
| Hospira, Inc. 755 Jarvis Drive Morgan Hill, CA 95037 United States | Date of Grant: 05/10/2007 Application Dated: 05/10/2007 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.04 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.049 |
| Class II Permissive Change to include specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configuration 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band.
|
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: |
| EA886718 |
TCB Grant - Application czcLZ/NSvKve/wwqNhdGMA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 | Date of Grant: 07/30/2007 Application Dated: 07/30/2007 |
| Hospira, Inc. |
| 755 Jarvis Drive |
| Morgan Hill, CA 95037 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.052 | ||
| CC | 15C | 5725.0 - 5825.0 | 0.041 |
| Class II Permissive Change to include a new specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in all Infusion Pump configurations are: 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. Highest reported SAR values in this Infusion Pump configuration are: 0.095 W/kg 2.4 GHz-band; 0.441 W/kg 5.2 GHz-band; 0.278 W/kg 5.5GHz band; 0.581 W/kg 5.8 GHz-band. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application czcLZ/NSvKve/wwqNhdGMA==
| COPY | FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION | COPY |
| Certification |
| Hospira, Inc. 755 Jarvis Drive Morgan Hill, CA 95037 United States | Date of Grant: 07/30/2007 Application Dated: 07/30/2007 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.052 | ||
| CC | 15C | 5725.0 - 5825.0 | 0.041 |
| Class II Permissive Change to include a new specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in all Infusion Pump configurations are: 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. Highest reported SAR values in this Infusion Pump configuration are: 0.095 W/kg 2.4 GHz-band; 0.441 W/kg 5.2 GHz-band; 0.278 W/kg 5.5GHz band; 0.581 W/kg 5.8 GHz-band.
|
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |
| EA812080 |
TCB Grant - Application cC9j+2eEQRDtHj2Ua0JRDw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 | Date of Grant: 03/19/2007 Application Dated: 03/19/2007 |
| Hospira, Inc. |
| 755 Jarvis Drive |
| Morgan Hill, CA 95037 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.052 | ||
| CC | 15C | 5725.0 - 5825.0 | 0.041 |
| Class II Permissive Change to include specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configuration 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application cC9j+2eEQRDtHj2Ua0JRDw==
| COPY | FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION | COPY |
| Certification |
| Hospira, Inc. 755 Jarvis Drive Morgan Hill, CA 95037 United States | Date of Grant: 03/19/2007 Application Dated: 03/19/2007 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.052 | ||
| CC | 15C | 5725.0 - 5825.0 | 0.041 |
| Class II Permissive Change to include specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configuration 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band.
|
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |
| EA750371 |
TCB Grant - Application b12sNsL/yOWSK+U+l7Xm5g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 | Date of Grant: 06/27/2007 Application Dated: 06/27/2007 |
| Hospira, Inc. |
| 755 Jarvis Drive |
| Morgan Hill, CA 95037 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.04 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.049 |
| Class II Permissive Change to include a specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configurations are: 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application b12sNsL/yOWSK+U+l7Xm5g==
| COPY | FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION | COPY |
| Certification |
| Hospira, Inc. 755 Jarvis Drive Morgan Hill, CA 95037 United States | Date of Grant: 06/27/2007 Application Dated: 06/27/2007 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.04 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.049 |
| Class II Permissive Change to include a specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in the Infusion Pump configurations are: 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band.
|
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: |
| EA351265 |
TCB Grant - Application 2zWYbsAm+0qVe2QDjlMTew==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION | TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
| UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 | Date of Grant: 07/30/2007 Application Dated: 07/30/2007 |
| Hospira, Inc. |
| 755 Jarvis Drive |
| Morgan Hill, CA 95037 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.04 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.049 |
| Class II Permissive Change to include a new specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in all Infusion Pump configurations are: 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. Highest reported SAR values in this Infusion Pump configuration are: 0.095 W/kg 2.4 GHz-band; 0.441 W/kg 5.2 GHz-band; 0.278 W/kg 5.5GHz band; 0.581 W/kg 5.8 GHz-band. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application 2zWYbsAm+0qVe2QDjlMTew==
| COPY | FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION | COPY |
| Certification |
| Hospira, Inc. 755 Jarvis Drive Morgan Hill, CA 95037 United States | Date of Grant: 07/30/2007 Application Dated: 07/30/2007 |
| Attention: Ashwin Patel |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | STJ80411396001 |
| Name of Grantee: | Hospira, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Wireless USB Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.04 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.04 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.049 |
| Class II Permissive Change to include a new specific infusion pump host configuration. Output is conducted. SAR compliance has been established in the laptop computer configurations with USB slot configurations as tested in this filing, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics. Compliance of this device in all final host configurations is the responsibility of the Grantee. End-users must be provided with specific information required to satisfy RF exposure compliance for all final host devices. Operations in the 5.15-5.25 GHz band are restricted to indoor-only use. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within a host device. The highest reported body SAR values for this composite filing are: 0.36 W/kg 2.4 GHz-band; 0.36 W/kg 5.2 GHz-band; 0.42 W/kg 5.8 GHz-band. Highest reported SAR values in all Infusion Pump configurations are: 0.78 W/kg 2.4 GHz-band; 1.458 W/kg 5.2 GHz-band; 1.416 W/kg 5.5GHz band; 0.826 W/kg 5.8 GHz-band. Highest reported SAR values in this Infusion Pump configuration are: 0.095 W/kg 2.4 GHz-band; 0.441 W/kg 5.2 GHz-band; 0.278 W/kg 5.5GHz band; 0.581 W/kg 5.8 GHz-band.
|
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: |
| EA856121 |