FCC ID STZSRM9000UW

UHF Mobile Tranceiver

by Simoco Australasia Pty Ltd

Grantee Code: STZ   Product Code: SRM9000UW
Latest application date: 2007-05-30

FCC ID Device Details

FCC IDSTZSRM9000UW
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSTZ
Product CodeSRM9000UW
Applicant BusinessSimoco Australasia Pty Ltd 🇦🇺
Related Domains simocogroup.com
Equipment ClassUHF Mobile Tranceiver
Test FirmEMC Technologies Pty. Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
440-512 MHzClass II permissive change or modification of presently authorized equipment2007-05-30
440-512 MHzOriginal Equipment2004-12-22

Exhibits

DocumentTypeAvailableFile
alignment manualParts List/Tune Up Info2007-05-30PDF 756.9 KB
service manualUsers Manual2007-05-30PDF 1.9 MB
users manualUsers Manual2007-05-30PDF 1.3 MB
USERS MANUAL 1Users Manual2004-12-22PDF 370.8 KB
USERS MANUAL 2Users Manual2004-12-22PDF 342 KB
internal photos 1Internal Photos2007-05-30PDF 518.8 KB
internal photos 2Internal Photos2007-05-30PDF 208.6 KB
INTERNAL PHOTOSInternal Photos2004-12-22PDF 443.6 KB
external photosExternal Photos2007-05-30PDF 370.9 KB
EXTERNAL PHOTOSExternal Photos2004-12-22PDF 263.1 KB
label sample and location 1ID Label/Location Info2007-05-30PDF 111.4 KB
label sample and location 2ID Label/Location Info2007-05-30PDF 254.4 KB
ID LABELID Label/Location Info2004-12-22PDF 145 KB
frequency programmingTest Report2007-05-30PDF 62.4 KB
spectrum efficiencyTest Report2007-05-30PDF 71.5 KB
test reportTest Report2007-05-30PDF 1.4 MB
TEST REPORTTest Report2004-12-22PDF 1.2 MB
class II change letterCover Letter(s)2007-05-30PDF 38.5 KB
request for confidentialityCover Letter(s)2007-05-30PDF 66.2 KB
CONFIDENTIALITY LETTERCover Letter(s)2004-12-22PDF 102.1 KB
radiation hazard assessmentRF Exposure Info2007-05-30PDF 14.9 KB
PARTS LIST 1Parts List/Tune Up Info2004-12-22PDF 86.6 KB
PARTS LIST 2Parts List/Tune Up Info2004-12-22PDF 9.6 KB
RF EXPOSURE 1RF Exposure Info2004-12-22PDF 80 KB
RF EXPOSURE 2RF Exposure Info2004-12-22PDF 117 KB
RF EXPOSURE 3RF Exposure Info2004-12-22PDF 24 KB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 35.3 KB
SCHEMATICS 1 Metadata onlySchematicsPDF 42.2 KB
SCHEMATICS 2 Metadata onlySchematicsPDF 43.9 KB
SCHEMATICS 3 Metadata onlySchematicsPDF 53.4 KB
SCHEMATICS 4 Metadata onlySchematicsPDF 46.6 KB
SCHEMATICS 5 Metadata onlySchematicsPDF 62.5 KB
SCHEMATICS 6 Metadata onlySchematicsPDF 69.3 KB
SCHEMATICS 7 Metadata onlySchematicsPDF 45.3 KB
SCHEMATICS 8 Metadata onlySchematicsPDF 63.1 KB
SCHEMATICS 9 Metadata onlySchematicsPDF 47.3 KB
OPERATIONAL DESCRIPTION Metadata onlyOperational DescriptionPDF 57.2 KB

Application Information

Application ID63v0jIEWFyuPD01nhlE3ug==
Final Action Date2007-05-30
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0010966224
ModelSRM9000UW
Frequency Range440-512 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionUHF Mobile Tranceiver
Responsible PartyRobert Stowell, Mr, Bob.Stowell@simocogroup.com , 0061-3-9730-3876
Test FirmMichael Evans, EMC Technologies Pty. Ltd., brisbane@emctech.com.au , 617-3875-2455
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users and Installers must be provided with the training information, antenna installation, and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 75cm from all persons and must not exceed an antenna gain of 0dBd. Power output is continuously variable from the value listed to 1 W.

Applications

Application IDDatePurpose
63v0jIEWFyuPD01nhlE3ug==2007-05-30Class II permissive change or modification of presently authorized equipment
9LhpEc+OGRL24cXX2RPtJg==2004-12-22Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
440-512 MHz252.5ppm11K0F3E22, 9
440-512 MHz252.5ppm8K00F1E22, 9
440-512 MHz252.5ppm16K0F3E22, 9
440-512 MHz252.5ppm11K0F1D22, 9
440-512 MHz252.5ppm16K0F1D22, 9
440-512 MHz252.5ppm11K2F1D22, 9

Grants

TCB Grant - Application 9LhpEc+OGRL24cXX2RPtJg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 12/22/2004

Application Dated: 12/22/2004
Simoco Wireless Solutions Pty Ltd
1270 Ferntree Gully Road
Scoresby
Melbourne, Victoria, 3179
Australia
 
Attention: Barend Gildenhuys , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  STZSRM9000UW
Name of Grantee:  Simoco Wireless Solutions Pty Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: UHF MOBILE TRANSMITTER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 90 440.0  -  512.0 25.0 2.5  PM 11K0F3E
22, 90 440.0  -  512.0 25.0 2.5  PM 8K00F1E
22, 90 440.0  -  512.0 25.0 2.5  PM 16K0F3E
22, 90 440.0  -  512.0 25.0 2.5  PM 11K0F1D
22, 90 440.0  -  512.0 25.0 2.5  PM 16K0F1D

Power listed is conducted.

Vehicle operation: This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 75cm from all persons and must not exceed an antenna gain of 0 dBd.

Fixed operation: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 90c????m from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 25W and the peak radiated output power must not exceed ????W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance.


EAS Grant - Application 9LhpEc+OGRL24cXX2RPtJg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Simoco Wireless Solutions Pty Ltd
1270 Ferntree Gully Road Scoresby
Melbourne, Victoria, 3179
Australia
  Date of Grant: 12/22/2004

Application Dated: 12/22/2004
 
Attention: Barend Gildenhuys , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  STZSRM9000UW
Name of Grantee:  Simoco Wireless Solutions Pty Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: UHF MOBILE TRANSMITTER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 90 440.0  -  512.0 25.0 2.5  PM 11K0F3E
22, 90 440.0  -  512.0 25.0 2.5  PM 8K00F1E
22, 90 440.0  -  512.0 25.0 2.5  PM 16K0F3E
22, 90 440.0  -  512.0 25.0 2.5  PM 11K0F1D
22, 90 440.0  -  512.0 25.0 2.5  PM 16K0F1D

Power listed is conducted.

Vehicle operation: This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 75cm from all persons and must not exceed an antenna gain of 0 dBd.

Fixed operation: The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 90c????m from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 25W and the peak radiated output power must not exceed ????W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance.



TCB Grant - Application 63v0jIEWFyuPD01nhlE3ug==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 05/30/2007

Application Dated: 05/25/2007
Simoco Australasia Pty Ltd
1270 Ferntree Gully Road
Scoresby
Melbourne, Victoria, 3179
Australia
 
Attention: Robert Stowell , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  STZSRM9000UW
Name of Grantee:  Simoco Australasia Pty Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: UHF Mobile Tranceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 90 440.0  -  512.0 25.0 2.5  PM 11K0F3E
22, 90 440.0  -  512.0 25.0 2.5  PM 8K00F1E
22, 90 440.0  -  512.0 25.0 2.5  PM 16K0F3E
22, 90 440.0  -  512.0 25.0 2.5  PM 16K0F1D
22, 90 440.0  -  512.0 25.0 2.5  PM 11K2F1D

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users and Installers must be provided with the training information, antenna installation, and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 75cm from all persons and must not exceed an antenna gain of 0dBd.

Power output is continuously variable from the value listed to 1 W.


EAS Grant - Application 63v0jIEWFyuPD01nhlE3ug==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Simoco Australasia Pty Ltd
1270 Ferntree Gully Road Scoresby
Melbourne, Victoria, 3179
Australia
  Date of Grant: 05/30/2007

Application Dated: 05/25/2007
 
Attention: Robert Stowell , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  STZSRM9000UW
Name of Grantee:  Simoco Australasia Pty Ltd
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: UHF Mobile Tranceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 90 440.0  -  512.0 25.0 2.5  PM 11K0F3E
22, 90 440.0  -  512.0 25.0 2.5  PM 8K00F1E
22, 90 440.0  -  512.0 25.0 2.5  PM 16K0F3E
22, 90 440.0  -  512.0 25.0 2.5  PM 16K0F1D
22, 90 440.0  -  512.0 25.0 2.5  PM 11K2F1D

Power listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users and Installers must be provided with the training information, antenna installation, and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 75cm from all persons and must not exceed an antenna gain of 0dBd.

Power output is continuously variable from the value listed to 1 W.



Mail To:


EA297696