FCC ID STZSRP9100TU

UHF Portable Transceiver

by Simoco Australasia Pty Ltd

Grantee Code: STZ   Product Code: SRP9100TU
Latest application date: 2007-07-03

FCC ID Device Details

FCC IDSTZSRP9100TU
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSTZ
Product CodeSRP9100TU
Applicant BusinessSimoco Australasia Pty Ltd 🇦🇺
Related Domains simocogroup.com
Equipment ClassUHF Portable Transceiver
Test FirmEMC Technologies NZ Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
406.1-480 MHzOriginal Equipment2007-07-03

Exhibits

DocumentTypeAvailableFile
service manualUsers Manual2007-07-03PDF 629.1 KB
users manualUsers Manual2007-07-03PDF 1.7 MB
internal photosInternal Photos2007-07-03PDF 982.5 KB
external photosExternal Photos2007-07-03PDF 158.8 KB
label sample and location 1ID Label/Location Info2007-07-03PDF 205.5 KB
label sample and location 2ID Label/Location Info2007-07-03PDF 30.6 KB
test setup photosTest Setup Photos2007-07-03PDF 193.3 KB
test reportTest Report2007-07-03PDF 1.3 MB
programmingAttestation Statements2007-07-03PDF 130.2 KB
spectrum efficiencyAttestation Statements2007-07-03PDF 146.1 KB
request for confidentialityCover Letter(s)2007-07-03PDF 138.6 KB
sar reportRF Exposure Info2007-07-03PDF 3.3 MB
tune up procedureParts List/Tune Up Info2007-07-03PDF 1.7 MB

Application Information

Application IDA36nEXWa+AmytZDa5naWCg==
Final Action Date2007-07-03
Application PurposeOriginal Equipment
Applicant FRN0010966224
ModelSRP9100TU
Frequency Range406.1-480 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionUHF Portable Transceiver
Responsible PartyRobert Stowell, Mr, Bob.Stowell@simocogroup.com , 0061-3-9730-3876
Test FirmAndrew Cutler, EMC Technologies NZ Ltd., auklab@ihug.co.nz , 64-9-360-0862
TCB Emailtei@timcoengr.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsMaximum conducted output power is 4.266W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, and accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Head: 1.31 W/kg for 50% Duty Cycle; Body: 6.1 W/kg for 50% Duty Cycle. Power output is continuously variable from the value listed to 0.5 W. This device contains functions that are not operational in U.S. Territories except as noted in this filing. This filing is only applicable for U.S. operations.

Applications

Application IDDatePurpose
A36nEXWa+AmytZDa5naWCg==2007-07-03Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
406.1-480 MHz52.5ppm11K2F3E22, 9
406.1-480 MHz52.5ppm8K10F1E22, 9
406.1-480 MHz52.5ppm11K2F1D22, 9
406.1-480 MHz52.5ppm16K0F3E22, 9
406.1-480 MHz52.5ppm16K0F1D22, 9

Grants

TCB Grant - Application A36nEXWa+AmytZDa5naWCg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 07/03/2007

Application Dated: 07/02/2007
Simoco Australasia Pty Ltd
1270 Ferntree Gully Road
Scoresby
Melbourne, Victoria, 3179
Australia
 
Attention: Robert Stowell , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  STZSRP9100TU
Name of Grantee:  Simoco Australasia Pty Ltd
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: UHF Portable Transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 90 406.1  -  480.0 5.0 2.5  PM 11K2F3E
22, 90 406.1  -  480.0 5.0 2.5  PM 8K10F1E
22, 90 406.1  -  480.0 5.0 2.5  PM 11K2F1D
22, 90 406.1  -  480.0 5.0 2.5  PM 16K0F3E
22, 90 406.1  -  480.0 5.0 2.5  PM 16K0F1D

Maximum conducted output power is 4.266W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, and accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Head: 1.31 W/kg for 50% Duty Cycle; Body: 6.1 W/kg for 50% Duty Cycle. Power output is continuously variable from the value listed to 0.5 W. This device contains functions that are not operational in U.S. Territories except as noted in this filing. This filing is only applicable for U.S. operations.

EAS Grant - Application A36nEXWa+AmytZDa5naWCg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Simoco Australasia Pty Ltd
1270 Ferntree Gully Road Scoresby
Melbourne, Victoria, 3179
Australia
  Date of Grant: 07/03/2007

Application Dated: 07/02/2007
 
Attention: Robert Stowell , Mr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  STZSRP9100TU
Name of Grantee:  Simoco Australasia Pty Ltd
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: UHF Portable Transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22, 90 406.1  -  480.0 5.0 2.5  PM 11K2F3E
22, 90 406.1  -  480.0 5.0 2.5  PM 8K10F1E
22, 90 406.1  -  480.0 5.0 2.5  PM 11K2F1D
22, 90 406.1  -  480.0 5.0 2.5  PM 16K0F3E
22, 90 406.1  -  480.0 5.0 2.5  PM 16K0F1D

Maximum conducted output power is 4.266W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, and accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Head: 1.31 W/kg for 50% Duty Cycle; Body: 6.1 W/kg for 50% Duty Cycle. Power output is continuously variable from the value listed to 0.5 W. This device contains functions that are not operational in U.S. Territories except as noted in this filing. This filing is only applicable for U.S. operations.



Mail To:


EA519841